A Comparison of the Flexural and Impact Strengths and Flexural Modulus of CAD/CAM and Conventional Heat-Cured Polymethyl Methacrylate (PMMA)

被引:95
|
作者
Al-Dwairi, Ziad N. [1 ]
Tahboub, Kawkab Y. [1 ]
Baba, Nadim Z. [2 ]
Goodacre, Charles J. [2 ]
机构
[1] JUST, Dept Prosthodont, Fac Dent, POB 3030, Irbid 22110, Jordan
[2] Loma Linda Univ, Sch Dent, Adv Specialty Educ Program Prosthodont, Loma Linda, CA 92350 USA
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2020年 / 29卷 / 04期
关键词
CAD; CAM; flexural strength; impact strength; MECHANICAL-PROPERTIES; COMPLETE DENTURES; POLY(METHYL METHACRYLATE); CAD-CAM; FABRICATION; REINFORCEMENT; RESISTANCE; POLYAMIDE; TRIAL;
D O I
10.1111/jopr.12926
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology to the field of removable prosthodontics has recently made it possible to fabricate complete dentures of prepolymerized polymethyl methacrylate (PMMA) blocks, which are claimed to be of better mechanical properties; however, no published reports that have evaluated mechanical properties of CAD/CAM PMMA. The purpose of this study was to compare flexural strength, impact strength, and flexural modulus of two brands of CAD/CAM PMMA and a conventional heat-cured PMMA. Materials and Methods 45 rectangular specimens (65 mm x 10 mm x 3 mm) were fabricated (15 CAD/CAM AvaDent PMMA specimens from AvaDent, 15 CAD/CAM Tizian PMMA specimens from Shutz Dental, 15 conventional Meliodent PMMA specimens from Heraeus Kulzer) and stored in distilled water at (37 +/- 1 degrees C) for 7 days. Specimens (N = 15) in each group were subjected to the three-point bending test and impact strength test, employing the Charpy configuration on unnotched specimens. The morphology of the fractured specimens was studied under a scanning electron microscope (SEM). Statistical analysis was performed using one-way ANOVA and Tukey pairwise multiple comparisons with 95% confidence interval. Results The Schutz Dental specimens showed the highest mean flexural strength (130.67 MPa) and impact strength (29.56 kg/m(2)). The highest mean flexural modulus was recorded in the AvaDent group (2519.6 MPa). The conventional heat-cured group showed the lowest mean flexural strength (93.33 MPa), impact strength (14.756 kg/m(2)), and flexural modulus (2117.2 MPa). Differences in means of flexural properties between AvaDent and Schutz Dental specimens were not statistically significant (p > 0.05). Conclusions As CAD/CAM PMMA specimens exhibited improved flexural strength, flexural modulus, and impact strength in comparison to the conventional heat-cured groups, CAD/CAM dentures are expected to be more durable. Different brands of CAD/CAM PMMA may have inherent variations in mechanical properties.
引用
收藏
页码:341 / 349
页数:9
相关论文
共 9 条
  • [1] Comparative Assessment of Flexural Strength in Heat-cured Polymethyl Methacrylate Resin Reinforced with Silver Nanoparticles, Siwak, and Fluconazole: An In-vitro Study
    Choure, Rupali
    Yadav, Naveen S.
    Somkuwar, Kirti
    Saxena, Vrinda
    Tiwari, Riddhi
    Bhatia, Ramnik
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2024, 18 (03) : ZC7 - ZC11
  • [2] Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers
    Alp, Gulce
    Murat, Sema
    Yilmaz, Burak
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E491 - E495
  • [3] Impact and flexural strength of kaolinite / glass fibers reinforced heat-cured acrylic denture
    Hussain W.A.
    Bader B.A.M.
    Slewa M.Y.
    Alwan L.H.
    Materials Science Forum, 2020, 1002 : 340 - 349
  • [4] A Color Stability Comparison of Conventional and CAD/CAM Polymethyl Methacrylate Denture Base Materials
    Dayan, Cagatay
    Guven, Melahat Celik
    Gencel, Burc
    Bural, Canan
    ACTA STOMATOLOGICA CROATICA, 2019, 53 (02) : 158 - 167
  • [5] Does Multifunctional Acrylate's Addition to Methacrylate Improve Its Flexural Properties and Bond Ability to CAD/CAM PMMA Block?
    Maruo, Yukinori
    Yoshihara, Kumiko
    Irie, Masao
    Nagaoka, Noriyuki
    Matsumoto, Takuya
    Minagi, Shogo
    MATERIALS, 2022, 15 (21)
  • [6] A Comparative Evaluation of Flexural and Impact Strength of Polymethyl Methacrylate (PMMA) Reinforced With Graphene and Multi-Walled Carbon Nanotubes: An In Vitro Study
    Swaroop, Neeranshi
    Katiyar, Pratibha
    Pandey, Kaushik Kumar
    Tarannum, Fauzia
    Umar, Mohd
    Paul, Swarupa
    Dayama, Nikhil, V
    Ahmed, Asra
    Singh, Ragini
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (06)
  • [7] Comparative Evaluation of the Flexural Strength of Heat-Activated Polymethyl Methacrylate Denture Base Resin With and Without 0.2% by the Weight of Silver Nanoparticles Cured by Conventional and Autoclave Methods: An In Vitro Study
    Sukumaran, Kala
    Ravindran, Smitha
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (06)
  • [8] Evaluation of Candida albicans Adherence to CAD-CAM Milled, 3D-Printed, and Heat-Cured PMMA Resin and Efficacy of Different Disinfection Techniques: An In Vitro Study
    Koujan, Amir
    Aggarwal, Himanshi
    Chen, Po-Hsu
    Li, Zhaofei
    Givan, Daniel A.
    Zhang, Ping
    Fu, Chin-Chuan
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (06): : 512 - 518
  • [9] Bond strength comparison of chemically activated hard reline materials on CAD-CAM milled and conventional heat-polymerized PMMA denture bases
    Bhumpattarachai, Sasiya
    Kan, Joseph Y. K.
    Goodacre, Charles J.
    Oyoyo, Udochukwu E.
    Vimonkittipong, Umaporn
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03): : 889e1 - 889e9