Performance and viability of absorptive dehumidification module using flat-sheet polytetrafluoroethylene/polypropylene composite membranes

被引:5
作者
Ham, Min-Gyu [1 ]
Jeon, Woo-Jin [1 ]
Kim, Hyung-Ju [1 ]
Bak, Chul-u [2 ]
Kim, Young-Deuk [2 ]
机构
[1] Hanyang Univ, Dept Mech Design Engn, 222 Wangsinmi Ro, Seoul 04763, South Korea
[2] Hanyang Univ, Dept Mech Engn, 55 Hanyangdaehak Ro, Ansan 15588, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
Dehumidification; Composite membrane; Liquid desiccant; Flat-sheet module; Performance evaluation; LIQUID DESICCANT DEHUMIDIFICATION; DIRECT-CONTACT MEMBRANE; AIR-CONDITIONING SYSTEM; ENERGY EXCHANGER LAMEE; SPACER-FILLED CHANNELS; MASS-TRANSFER; PARAMETRIC ANALYSIS; COOLING SYSTEM; HEAT; FLOW;
D O I
10.1016/j.enconman.2019.112393
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study developed a flat-sheet absorptive dehumidification module using a commercial polytetrafluoroethylene/polypropylene composite membrane and evaluated its performance. The composite membrane consisted of an active layer of polytetrafluoroethylene and a scrim-backing support layer of polypropylene, both of which were in direct contact with humid air and a lithium chloride aqueous solution. Experimental tests were performed on key operating parameters such as the relative humidity, temperature, and superficial velocity of the humid air, and the temperature and superficial velocity of the desiccant solution. The performance of the module was evaluated in terms of the moisture permeate flux and effectiveness (e.g., sensible and latent). The results demonstrated that, under the given operating conditions, increasing all the humid air-related parameters synergistically affected the moisture permeate flux (especially noticeable in temperature), and that the moisture permeate flux was adversely affected by the solution temperature and virtually unaffected by the solution velocity. Both stream temperatures had a significant effect on the sensible effectiveness; moreover, the sensible effectiveness decreased linearly with increasing relative humidity and velocity of humid air, whereas the effect of the solution velocity was negligible. Conversely, all the parameters, except for the air temperature and velocity, had negligible influences on the latent effectiveness. The dehumidification module using composite membranes achieved a moisture permeate flux of 1963 g(w)/m(2)h and sensible and latent effectivenesses of 68% and 69%, respectively, under the baseline operating conditions, providing notably improved performance compared to existing dehumidification modules.
引用
收藏
页数:12
相关论文
共 40 条
  • [1] Design and testing of a novel 3-fluid liquid-to-air membrane energy exchanger (3-fluid LAMEE)
    Abdel-Salam, Mohamed R. H.
    Besant, Robert W.
    Simonson, Carey J.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 92 : 312 - 329
  • [2] An experimental study for the characterization of fluid dynamics and heat transport within the spacer-filled channels of membrane distillation modules
    Albeirutty, M.
    Turkmen, N.
    Al-Sharif, S.
    Bouguecha, S.
    Malik, A.
    Faruki, O.
    Cipollina, A.
    Ciofalo, M.
    Micale, G.
    [J]. DESALINATION, 2018, 430 : 136 - 146
  • [3] [Anonymous], 2018, STAT KOR 2018
  • [4] Influences of the mixed LiCl-CaCl2 liquid desiccant solution on a membrane-based dehumidification system: Parametric analysis and mixing ratio selection
    Bai, Hongyu
    Zhu, Jie
    Chu, Junze
    Chen, Xiangjie
    Cui, Yuanlong
    Yan, Yuying
    [J]. ENERGY AND BUILDINGS, 2019, 183 : 592 - 606
  • [5] Parametric analysis of a cross-flow membrane-based parallel-plate liquid desiccant dehumidification system: Numerical and experimental data
    Bai, Hongyu
    Zhu, Jie
    Chen, Ziwei
    Chu, Junze
    [J]. ENERGY AND BUILDINGS, 2018, 158 : 494 - 508
  • [6] On the performances of a hybrid air-conditioning system in different climatic conditions
    Bergero, Stefano
    Chiari, Anna
    [J]. ENERGY, 2011, 36 (08) : 5261 - 5273
  • [7] Performance assessment of a membrane liquid desiccant dehumidification cooling system based on experimental investigations
    Chen, Ziwei
    Zhu, Jie
    Bai, Hongyu
    [J]. ENERGY AND BUILDINGS, 2017, 139 : 665 - 679
  • [8] Experimental investigations on a solar assisted liquid desiccant cooling system with indirect contact dehumidifier
    Das, Rajat Subhra
    Jain, Sanjeev
    [J]. SOLAR ENERGY, 2017, 153 : 289 - 300
  • [9] Performance characteristics of cross-flow membrane contactors for liquid desiccant systems
    Das, Rajat Subhra
    Jain, Sanjeev
    [J]. APPLIED ENERGY, 2015, 141 : 1 - 11
  • [10] Experimental performance of indirect air-liquid membrane contactors for liquid desiccant cooling systems
    Das, Rajat Subhra
    Jain, Sanjeev
    [J]. ENERGY, 2013, 57 : 319 - 325