Reagent-loaded cartridges for valveless and automated fluid delivery in microfluidic devices

被引:132
作者
Linder, V [1 ]
Sia, SK [1 ]
Whitesides, GM [1 ]
机构
[1] Harvard Univ, Dept Chem & Chem Biol, Cambridge, MA 02138 USA
关键词
D O I
10.1021/ac049071x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An important problem in the life sciences and in health care is simple and rapid detection of biomarkers. Although microfluidic devices are potentially useful in addressing this problem, current techniques for automating fluid delivery-which include valves and electro-osmosis-require sophisticated microfabrication of the chip, bulky instrumentation, or both. In this paper, we describe a simple and reliable technique for storing and delivering a sequence of reagents to a microfluidic device. The technique is low-cost, requires minimal user intervention, and can be performed in resource-poor settings (e.g., outside of a laboratory) in the absence of electricity and computer-controlled equipment. In this method, cartridges made of commercially available tubing are filled by sequentially injecting plugs of reagents separated by air spacers. The air spacers prevent the reagents from mixing with each other during cartridge preparation, storage, and usage. As an example, we used this "plug-in cartridge" technology to complete a solid-phase immunoassay in a microchannel in 2 min with low-nanomolar sensitivity and demonstrate the diagnosis of HIV in 13 min.
引用
收藏
页码:64 / 71
页数:8
相关论文
共 31 条
  • [1] Biotechnology and the UN's millennium development goals
    Acharya, T
    Daar, AS
    Singer, PA
    [J]. NATURE BIOTECHNOLOGY, 2003, 21 (12) : 1434 - 1436
  • [2] [Anonymous], 2003, HDB CHEM PHYS
  • [3] Micro total analysis systems. 2. Analytical standard operations and applications
    Auroux, PA
    Iossifidis, D
    Reyes, DR
    Manz, A
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (12) : 2637 - 2652
  • [4] Micromosaic immunoassays
    Bernard, A
    Michel, B
    Delamarche, E
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (01) : 8 - 12
  • [5] The role of vitrification in anhydrobiosis
    Crowe, JH
    Carpenter, JF
    Crowe, LM
    [J]. ANNUAL REVIEW OF PHYSIOLOGY, 1998, 60 : 73 - 103
  • [6] Electrokinetically driven microfluidic chips with surface-modified chambers for heterogeneous immunoassays
    Dodge, A
    Fluri, K
    Verpoorte, E
    de Rooij, NF
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (14) : 3400 - 3409
  • [7] Rapid prototyping of microfluidic systems in poly(dimethylsiloxane)
    Duffy, DC
    McDonald, JC
    Schueller, OJA
    Whitesides, GM
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (23) : 4974 - 4984
  • [8] Solving mazes using microfluidic networks
    Fuerstman, MJ
    Deschatelets, P
    Kane, R
    Schwartz, A
    Kenis, PJA
    Deutch, JM
    Whitesides, GM
    [J]. LANGMUIR, 2003, 19 (11) : 4714 - 4722
  • [9] A rapid diffusion immunoassay in a T-sensor
    Hatch, A
    Kamholz, AE
    Hawkins, KR
    Munson, MS
    Schilling, EA
    Weigl, BH
    Yager, P
    [J]. NATURE BIOTECHNOLOGY, 2001, 19 (05) : 461 - 465
  • [10] Flow-based microimmunoassay
    Hayes, MA
    Polson, NA
    Phayre, AN
    Garcia, AA
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (24) : 5896 - 5902