Development of a sequential injection dispersive liquid-liquid microextraction system for electrothermal atomic absorption spectrometry by using a hydrophobic sorbent material: Determination of lead and cadmium in natural waters

被引:121
作者
Anthemidis, Aristidis N. [1 ]
Ioannou, Kallirroy-Ioanna G. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Analyt Chem Lab, Thessaloniki 54124, Greece
关键词
Sequential injection; Dispersive liquid liquid microextraction; Atomic spectrometry; Cadmium; Lead; TRACE ONLINE PRECONCENTRATION; EXTRACTION SYSTEM; METAL-IONS; SEPARATION; SAMPLES; SI;
D O I
10.1016/j.aca.2009.10.063
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel on-line sequential injection (SI) dispersive liquid-liquid microextraction (DLLME) system coupled to electrothermal atomic absorption spectrometry (ETAAS) was developed for metal preconcentration in micro-scale, eliminating the laborious and time consuming procedure of phase separation with centrifugation. The potentials of the system were demonstrated for trace lead and cadmium determination in water samples. An appropriate disperser solution which contains the extraction solvent (xylene) and the chelating agent (ammonium pyrrolidine dithiocarbamate) in methanol is mixed on-line with the sample solution (aqueous phase), resulting thus, a cloudy solution, which is consisted of fine droplets of xylene, dispersed throughout the aqueous phase. Three procedures are taking place simultaneously: cloudy solution creation, analyte complex formation and extraction from aqueous phase into the fine droplets of xylene. Subsequently the droplets were retained on the hydrophobic surface of PTFE-turnings into the column. A part of 30 mu L of the eluent (methyl isobutyl ketone) was injected into furnace graphite for analyte atomization and quantification. The sampling frequency was 10 h(-1), and the obtained enrichment factor was 80 for lead and 34 for cadmium. The detection limit was 10 ng L-1 and 2 ng L-1, while the precision expressed as relative standard deviation (RSD) was 3.8% (at 0.5 mu g L-1) and 4.1% (at 0.03 mu g L-1) for lead and cadmium respectively. The proposed method was evaluated by analyzing certified reference materials and was applied to the analysis of natural waters. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 40
页数:6
相关论文
共 23 条
[1]   Flow injection wetting-film extraction system for flame atomic absorption spectrometric determination of cadmium in environmental waters [J].
Adam, Ibrahim S. I. ;
Anthemidis, Aristidis N. .
TALANTA, 2009, 77 (03) :1160-1164
[2]  
[Anonymous], 1995, Standard methods for examination of water and waste water, V19th
[3]   Cobalt ultra-trace on-line preconcentration and determination using a PTFE turnings packed column and electrothermal atomic absorption spectrometry. Applications in natural waters and biological samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) :1330-1334
[4]   Development of an on-line solvent extraction system for electrothermal atomic absorption spectrometry utilizing a new gravitational phase separator. Determination of cadmium in natural waters and urine samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (11) :1400-1403
[5]   On-line sequential injection dispersive liquid-liquid microextraction system for flame atomic absorption spectrometric determination of copper and lead in water samples [J].
Anthemidis, Aristidis N. ;
Ioannou, Kallirroy-Ioanna G. .
TALANTA, 2009, 79 (01) :86-91
[6]   Determination of lead in water samples by graphite furnace atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Xiao, SM ;
Wu, XH ;
Fang, KM ;
Liu, WH .
TALANTA, 2005, 67 (05) :992-996
[7]   How flow-injection analysis (FIA) over the past 25 years has changed our way of performing chemical analyses [J].
Hansen, Elo Harald ;
Miro, Manuel .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (01) :18-26
[8]   Dispersive liquid-liquid microextraction combined with graphite furnace atomic absorption spectrometry - Ultra trace determination of cadmium in water samples [J].
Jahromi, Elham Zeini ;
Bidari, Araz ;
Assadi, Yaghoub ;
Hosseini, Mohammad Reza Milani ;
Jamali, Mohammad Reza .
ANALYTICA CHIMICA ACTA, 2007, 585 (02) :305-311
[9]   Dispersive liquid phase microextraction (DLPME) combined with graphite furnace atomic absorption spectrometry (GFAAS) for determination of trace Co and Ni in environmental water and rice samples [J].
Jiang, Hongmei ;
Qin, Yongchao ;
Hu, Bin .
TALANTA, 2008, 74 (05) :1160-1165
[10]   Ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction combined with electrothermal atomic absorption spectrometry for a sensitive determination of cadmium in water samples [J].
Li, Shengqing ;
Cai, Shun ;
Hu, Wei ;
Chen, Hao ;
Liu, Hanlan .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (07) :666-671