Reducing the small-heart effect in pediatric gated myocardial perfusion single-photon emission computed tomography

被引:10
作者
Yoneyama, Hiroto [1 ]
Nakajima, Kenichi [2 ]
Okuda, Koichi [3 ]
Matsuo, Shinro [2 ]
Onoguchi, Masahisa [4 ]
Kinuya, Seigo [2 ]
Edenbrandt, Lars [5 ]
机构
[1] Kanazawa Univ Hosp, Dept Radiol Technol, 13-1 Takara Machi, Kanazawa, Ishikawa 9208641, Japan
[2] Kanazawa Univ Hosp, Dept Nucl Med, Kanazawa, Ishikawa, Japan
[3] Kanazawa Med Univ, Dept Phys, Kanazawa, Ishikawa, Japan
[4] Kanazawa Univ, Grad Sch Med Sci, Dept Hlth Sci, Kanazawa, Ishikawa, Japan
[5] Univ Gothenburg, Dept Mol & Clin Med, Gothenburg, Sweden
关键词
Ejection fraction; small-heart effect; resolution correction; quantitative gated SPECT; cardioREPO; 360-DEGREES DATA-COLLECTION; LEFT-VENTRICULAR FUNCTION; SOFT-TISSUE TUMORS; EJECTION FRACTION; NUCLEAR-MEDICINE; RECONSTRUCTION PARAMETERS; ATTENUATION CORRECTION; J-ACCESS; SPECT; VOLUMES;
D O I
10.1007/s12350-016-0518-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We compared two reconstruction algorisms and two cardiac functional evaluation software programs in terms of their accuracy for estimating ejection fraction (EF) of small hearts (SH). Methods. The study group consisted of 66 pediatric patients. Data were reconstructed using a filtered back projection (FBP) method without the resolution correction (RC) and an iterative method based on an ordered subset expectation maximization (OSEM) algorithm with the RC. EF was evaluated using two software programs of quantitative gated single-photon emission computed tomography (SPECT) (QGS) and cardioREPO. We compared the EF of gated myocardial perfusion SPECT to echocardiographic measurement (Echo). Results. Forty-eight of 66 patients had an end-systolic volume < 20 mL which was used as the criterion for being included in the SH group, and the SH effect led to an overestimation of EF. While significant differences were observed between Echo (66.9 +/- 5.0%) and QGS-FBP without RC (76.9 +/- 8.4%, P < .0001), QGS-OSEM with RC (76.6 +/- 8.6%, P < .0001), and cardioREPO-FBP without RC (72.1 +/- 10.0%, P = .0011), no significant difference was observed between Echo and cardioREPO-OSEM with RC (67.4 +/- 6.1%) in SH group. Conclusions. In pediatric gated myocardial perfusion SPECT, the SH effect can be significantly reduced when an OSEM algorithm is used with RC in combination with the specific cardioREPO algorithm.
引用
收藏
页码:1378 / 1388
页数:11
相关论文
共 47 条
  • [1] Akaishi M., 2006, JPN J MED ULTRASON, V33, P371
  • [2] Half-Time SPECT Myocardial Perfusion Imaging with Attenuation Correction
    Ali, Iftikhar
    Ruddy, Terrence D.
    Almgrahi, Abdulaziz
    Anstett, Frank G.
    Wells, R. Glenn
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (04) : 554 - 562
  • [3] Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation
    Buechel, Ronny R.
    Herzog, Bernhard A.
    Husmann, Lars
    Burger, Irene A.
    Pazhenkottil, Aju P.
    Treyer, Valerie
    Valenta, Ines
    von Schulthess, Patrick
    Nkoulou, Rene
    Wyss, Christophe A.
    Kaufmann, Philipp A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (04) : 773 - 778
  • [4] COLEMAN RE, 1982, J NUCL MED, V23, P655
  • [5] Cwajg E, 1999, J NUCL MED, V40, P1857
  • [6] Comparison between Tc-99m-sestamibi gated myocardial perfusion SPECT and echocardiography in assessment of left ventricular volumes and ejection fraction - effect of perfusion defect and small heart
    Danesh-Sani, Seyed Hashem
    Zakavi, Seyed Rasoul
    Oskoueian, Leyla
    Kakhki, Vahid-Reza Dabbagh
    [J]. NUCLEAR MEDICINE REVIEW, 2014, 17 (02) : 70 - 74
  • [7] Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: A comparison to "full-time" filtered backprojection
    DePuey, E. Gordon
    Gadiraju, Ramesh
    Clark, John
    Thompson, Linda
    Anstett, Frank
    Shwartz, Shuli C.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2008, 15 (04) : 547 - 563
  • [8] Effects of acquisition time and reconstruction algorithm on image quality, quantitative parameters, and clinical interpretation of myocardial perfusion imaging
    Enevoldsen, Lotte H.
    Menashi, Changez A. K.
    Andersen, Ulrik B.
    Jensen, Lars T.
    Henriksen, Otto M.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (06) : 1086 - 1092
  • [9] Minimizing and Communicating Radiation Risk in Pediatric Nuclear Medicine
    Fahey, Frederic H.
    Treves, S. Ted
    Adelstein, S. James
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (08) : 1240 - 1251
  • [10] Variability of left ventricular ejection fraction and volumes with quantitative gated SPECT: influence of algorithm, pixel size and reconstruction parameters in small and normal-sized hearts
    Hambye, AS
    Vervaet, A
    Dobbeleir, A
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (12) : 1606 - 1613