Usefulness of triphasic CT aortic angiography in acute and surveillance: Our experience in the assessment of acute aortic dissection and endoleak

被引:17
作者
Reginelli, Alfonso [1 ]
Capasso, Raffaella [1 ]
Ciccone, Vincenzo [2 ]
Croce, Maria Rosaria [1 ]
Di Grezia, Graziella [1 ]
Carbone, Mattia [3 ]
Maggialetti, Nicola [4 ]
Barile, Antonio [5 ]
Fonio, Paolo [6 ]
Scialpi, Michele [2 ]
Brunese, Luca [4 ]
机构
[1] Univ Naples 2, Inst Radiol, Dept Internal & Expt Med, Piazza Miraglia 2, I-80138 Naples, Italy
[2] Univ Perugia, Div Radiol 2, Dept Surg & Biomed Sci, Perugia, Italy
[3] San Giovanni di Dio & Ruggi Daragona Hosp, Dept Radiol, Salerno, Italy
[4] Univ Molise, Dept Med & Hlth Sci, Campobasso, Italy
[5] Univ Aquila, Dept Clin Sci, Laquila, Italy
[6] Radiol Univ Turin, Dept Diagnost Imaging & Radiotherapy, Turin, Italy
关键词
Computed tomography angiography (CTA); Triphasic CTA; Acute aortic dissection; Endoleaks; EVAR; STENT-GRAFT TREATMENT; ANEURYSM REPAIR; COMPUTED-TOMOGRAPHY; ENDOVASCULAR REPAIR; THORACIC AORTA; FOLLOW-UP; COMPLICATIONS; DIAGNOSIS; MANAGEMENT; DISEASE;
D O I
10.1016/j.ijsu.2016.05.048
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Computed tomography angiography (CTA) has been widely used in the diagnostic evaluation of many aortic diseases, but no standardized techniques actually exist for aortic CTA. The aim of this study was to describe the usefulness of triphasic CTA in aortic assessment in both non-traumatic emergency and surveillance conditions. Methods: We performed non ECG-gated CTA examinations with a 64-slice CT scanner using a triphasic protocol consisting of an unenhanced acquisition, and two (early and delayed) contrastographic phases with a delay of 25-30 s and 100-120 s respectively after the injection of contrast medium. Were retrospectively selected adult patients with imaging findings of acute aortic dissection (AAD) or endoleak (EL) from November 2012 to November 2014. Results: AAD was detected in 36 (67%) patients: 23 type A-AADs, and 13 type B-AADs. The presence of EL was observed in 18 (33%) patients: 1 type Ia, 5 types IIa, 2 types IIb, 1 type IIIa and 9 types IIIb. Discussion: Triphasic CTA is useful to provide correct and prompt diagnosis of AAD in emergency, allowing the evaluation of type and atypical forms of AAD, and the identification of possible branchvessel involvement and complications. During surveillance, triphasic CTA assures accurate and complete assessment of all known and unknown ELs and it is essential for first follow-up examination. Conclusion: Triphasic CTA represents a reliable imaging tool for aortic assessment in both non-traumatic emergency and surveillance after endovascular aneurysm repair. Modified protocol could be employed in selected patients and tailored in their known disease. (C) 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:S76 / S84
页数:9
相关论文
共 41 条
[1]   Endoleaks After Endovascular Abdominal Aortic Aneurysm Repair: Management Strategies According to CT Findings [J].
Bashir, Mustafa R. ;
Ferral, Hector ;
Jacobs, Chad ;
McCarthy, Walter ;
Goldin, Marshall .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) :W178-W186
[2]   Pitfalls in the diagnosis of thoracic aortic dissection at CT angiography [J].
Batra, P ;
Bigoni, B ;
Manning, J ;
Aberle, DR ;
Brown, K ;
Hart, E ;
Goldin, J .
RADIOGRAPHICS, 2000, 20 (02) :309-320
[3]  
Bown MJ, 2004, J CARDIOVASC SURG, V45, P335
[4]   Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair [J].
Buffa, Vitaliano ;
Solazzo, Antonio ;
D'Auria, Valeria ;
Del Prete, Alessandra ;
Vallone, Andrea ;
Luzietti, Monica ;
Madau, Manuela ;
Grassi, Roberto ;
Miele, Vittorio .
RADIOLOGIA MEDICA, 2014, 119 (12) :934-941
[5]   CT in nontraumatic acute thoracic aortic disease:: Typical and atypical features and complications [J].
Castañer, E ;
Andreu, M ;
Gallardo, X ;
Mata, JM ;
Cabezuelo, MA ;
Pallardó, Y .
RADIOGRAPHICS, 2003, 23 :S93-S110
[6]   DETECTION OF THE INTIMAL FLAP OF AORTIC DISSECTION ON UNENHANCED CT IMAGES [J].
DEMOS, TC ;
POSNIAK, HV ;
CHURCHILL, RJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 146 (03) :601-603
[7]   Endovascular stent-graft treatment of thoracic aortic syndromes: A 7-year experience [J].
Dialetto, Giovanni ;
Reginelli, Alfonso ;
Cerrato, Marcella ;
Rossi, Giovanni ;
Covino, Franco Enrico ;
Manduca, Sabrina ;
Lassandro, Francesco .
EUROPEAN JOURNAL OF RADIOLOGY, 2007, 64 (01) :65-72
[8]   C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications [J].
Floridi, Chiara ;
Radaelli, Alessandro ;
Abi-Jaoudeh, Nadine ;
Grass, Micheal ;
De Lin, Ming ;
Chiaradia, Melanie ;
Geschwind, Jean-Francois ;
Kobeiter, Hishman ;
Squillaci, Ettore ;
Maleux, Geert ;
Giovagnoni, Andrea ;
Brunese, Luca ;
Wood, Bradford ;
Carrafiello, Gianpaolo ;
Rotondo, Antonio .
RADIOLOGIA MEDICA, 2014, 119 (07) :521-532
[9]   Evaluation and Treatment of Suspected Type II Endoleaks in Patients with Enlarging Abdominal Aortic Aneurysms [J].
Funaki, Brian ;
Birouti, Nour ;
Zangan, Steven M. ;
Van Ha, Thuong G. ;
Lorenz, Jonathan M. ;
Navuluri, Rakesh ;
Skelly, Christopher L. ;
Leef, Jeffrey A. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 23 (07) :866-872
[10]   Endovascular stent-graft treatment of thoracic aortic disease [J].
Garzón, G ;
Fernández-Velilla, M ;
Martí, M ;
Acitores, I ;
Ybáñez, F ;
Riera, L .
RADIOGRAPHICS, 2005, 25 :S229-S245