Anticoagulation in syncardia total artificial heart recipients: anti-factor Xa or activated partial thromboplastin time?

被引:0
|
作者
Monteagudo-Vela, Maria [1 ]
Bowles, Christopher [1 ]
Raj, Binu [1 ]
Robinson, Derek [2 ]
Simon, Andre [1 ]
机构
[1] Guys & St ThomasNHS Fdn Trust, Dept Cardiothorac Transplantat & Mech Circulatory, Harefield Hosp, London, England
[2] Univ Sussex, Dept Math, 3A20 Pevensey 2 Bldg,Falmer Campus, Brighton, E Sussex, England
关键词
Total artificial heart; Anticoagulation protocol; aPTT; Anti-FXa assay; VON-WILLEBRAND-FACTOR; PULSATILITY;
D O I
10.1093/icvts/ivab251
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The activated partial thromboplastin time (aPTT) has been the historical method of choice for anticoagulation monitoring in patients undergoing mechanical circulatory support with intravenous unfractionated heparin (IVUFH). Although the activated partial thromboplastin time (aPTT) has historically been the method of choice for anticoagulation monitoring in patients undergoing mechanical circulatory support with intravenous unfractionated heparin, it is being progressively superseded by the anti-factor Xa (anti-Xa) method. A retrospective single-arm, single-centre analysis of 20 patients who underwent total artificial heart implantation entailed simultaneous determinations of aPTT and anti-Xa. Agreement between these parameters was assessed using the Bland-Altman method. Despite a positive correlation between aPTT and anti-Xa, normal target ranges were poorly aligned: from 5th to 30th postoperative day, for anti-Xa values of 0.2 and 0.4 U/ml corresponding aPTT values were 52.1 and 65.2 s, 7.9 and 14.8 lower than predicted values, respectively. This was not associated with thromboembolic sequalae. It was not possible to demonstrate a significant relationship between the predictor variables (postoperative day; white blood cell count; C-reactive protein concentration; alanine transaminase and alkaline phosphatase level; bilirubin; haemoglobin; albumin and total protein concentration) and the agreement between aPTT and anti-Xa levels. In summary, when anti-Xa levels were used to guide anticoagulation therapy, corresponding aPTT levels were low with respect to target range. Methodology applied in this study is generalizable to other forms of mechanical circulatory support.
引用
收藏
页码:322 / 325
页数:4
相关论文
共 50 条
  • [21] Interlaboratory agreement in the monitoring of unfractionated heparin using the anti-factor Xa-correlated activated partial thromboplastin time: a rebuttal
    Kitchen, S.
    Preston, F. E.
    Jennings, I.
    Kitchen, D. P.
    Woods, T. A. L.
    Walker, I.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 (12) : 2157 - 2158
  • [22] IMPROVING CLINICAL DECISION MAKING FOR HEPARINIZED PATIENTS WITH DISCORDANT ANTI-FACTOR XA ACTIVITY AND ACTIVATED PARTIAL THROMBOPLASTIN TIME.
    Gombar, Saurabh
    Krishnan, Anandi
    Zehnder, James
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2017, 39 : 40 - 40
  • [23] The Distribution of Anti-factor Xa Activity Values, Prothrombin Time and Activated Partial Thromboplastin Time Assessed at Multiple Points in Patients on Edoxaban Therapy
    Ono, Ryohei
    Fukushima, Kenichi
    Takahashi, Hidehisa R.
    Hori, Yasuhiko
    Kobayashi, Yoshio
    CIRCULATION, 2020, 142
  • [24] Anticoagulation via anti-Factor Xa inhibition
    Wiles, N
    Hunt, BJ
    LUPUS, 2006, 15 (03) : 167 - 171
  • [25] Interlaboratory agreement in the monitoring of unfractionated heparin using the anti-factor Xa-correlated activated partial thromboplastin time: reply to a rebuttal
    Cuker, A.
    Cines, D. B.
    Pollak, E. S.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 (12) : 2158 - 2159
  • [26] SAFETY OF MONITORING UNFRACTIONATED HEPARIN INFUSIONS IN CRITICALLY ILL PATIENTS: ANTI-FACTOR XA VERSUS ACTIVATED PARTIAL THROMBOPLASTIN TIME (APTT)
    Burka, Abigail
    Cunningham, Michael
    Ernst, Neil
    Droege, Chris
    Hillebrand, Kristen
    Clark, Lindsey
    Tsuei, Betty
    Mueller, Eric
    CRITICAL CARE MEDICINE, 2012, 40 (12) : U279 - U279
  • [27] Anti-Factor Xa Assay Is a Superior Correlate of Heparin Dose Than Activated Partial Thromboplastin Time or Activated Clotting Time in Pediatric Extracorporeal Membrane Oxygenation
    Liveris, Anna
    Bello, Ricardo A.
    Friedmann, Patricia
    Duffy, Melissa A.
    Manwani, Deepa
    Killinger, James S.
    Rodriquez, Daniel
    Weinstein, Samuel
    PEDIATRIC CRITICAL CARE MEDICINE, 2014, 15 (02) : E72 - E79
  • [28] Increased Mortality and Bleeding in a Large Cohort of Patients on Heparin Anticoagulation Therapy with Discordant Anti-Factor Xa Activity and Activated Partial Thromboplastin Time (PTT); Implications for Clinical Management
    Gombar, Saurabh
    Boothroyd, Derek
    Krishnan, Anandi
    Sharifi, Husham
    Hsu, Joe
    Zehnder, James
    BLOOD, 2019, 134
  • [29] Determining Cause for Activated Partial Thromboplastin Time and Anti-Factor Xa Discordance in Mechanical Circulatory Support Patients on Heparin; Can Thromboelastogram Help?
    Volod, O.
    Lam, L.
    Robert, C.
    Moriguchi, J.
    Yur, J.
    Garcia, M.
    Zhou, J.
    Wilde, A.
    Czer, L.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S463 - S463
  • [30] CASE CONTROL STUDY OF THE PERFORMANCE OF ACTIVATED PARTIAL THROMBOPLASTIN TIME VERSUS ANTI-FACTOR XA ACTIVITY FOR THE MONITORING OF THERAPEUTIC UNFRACTIONATED HEPARIN IN PEDIATRICS
    Trucco, Matteo
    Lehmann, Christoph
    Mollenkopf, Nicole
    Takemoto, Cliff
    PEDIATRIC BLOOD & CANCER, 2013, 60 : S32 - S32