Molecular Beacon-Based Fluorescent Assay for Specific Detection of Oversulfated Chondroitin Sulfate Contaminants in Heparin without Enzyme Treatment

被引:21
作者
Lee, Chih-Yi [1 ]
Tseng, Wei-Lung [1 ,2 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 80424, Taiwan
[2] Kaohsiung Med Univ, Coll Pharm, Sch Pharm, Kaohsiung 80708, Taiwan
关键词
INDUCED THROMBOCYTOPENIA; INHIBITION; SODIUM;
D O I
10.1021/acs.analchem.5b00692
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Oversulfated chondroitin sulfate (OSCS) is a harmful coutaminant in the pharmaceutical heparin. The development of a rapid,, convenient, Sensitive, and Selective method is required for routine analysis of OSCS in pharmaceutical heparin. Here we report a simple, rapid; sensitive, and enzyme-free method for detecting OSCS in heparin based on the competitive binding between OSCS and the adenosine-repeated molecular beacon (MB) stem to coralyne in the presence of Ca2+ ions. The MB (A(8)-MB-A(8)) contains a 22-mer loop, a stem of a pair of 8-mer adenosine (A) bases, a fluorophore unit at the S'-end, and a quencher at the 3'-end. The presence of coralyne promotes these A A. mismatches to form a hairpin-shaped MB. However, this kind of MB is incapable of differentiating between heparin and OSCS because they both exhibit strong electrostatic attraction with coralyne. This study found that while Ca2+ ions can efficiently suppress the negative charges of heparin, they do not neutralize the negative charge of OSCS. Thus, in the presence of Ca2+ ions, OSCS can remove coralyne from the MB stein, initiating fluorescence of the MB. Under optimal conditions (10 nM A(8)-MB-A(8), 800 nMicoralyne, and 0.5 mM Ca2+ ions), the proposed system can detect 0.01% w/w OSCS in heparin in under 5 mkt Without enzyme treatment. This study also validates the practicality of the proposed system to determine 0:01% w/w OSCS in the pharmaceutical heparin.
引用
收藏
页码:5031 / 5035
页数:5
相关论文
共 27 条
[1]   Competitive Inhibition of Heparinase by Persulfonated Glycosaminoglycans: A Tool to Detect Heparin Contamination [J].
Aich, Udayanath ;
Shriver, Zachary ;
Tharakaraman, Kannan ;
Raman, Rahul ;
Sasisekharan, Ram .
ANALYTICAL CHEMISTRY, 2011, 83 (20) :7815-7822
[2]   Combination of a two-step fluorescence assay and a two-step anti-Factor Xa assay for detection of heparin falsifications and protein in heparins [J].
Alban, Susanne ;
Luehn, Susanne ;
Schiemann, Simone .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (02) :681-690
[3]   Identification of a simple and sensitive microplate method for the detection of oversulfated chondroitin sulfate in heparin products [J].
Bairstow, Shawn ;
McKee, Jeff ;
Nordhaus, Mark ;
Johnson, Richard .
ANALYTICAL BIOCHEMISTRY, 2009, 388 (02) :317-321
[4]   Composition of OSCS-contaminated heparin occurring in 2008 in batches on the German market [J].
Beyer, Tanja ;
Matz, Magnus ;
Brinz, Daniela ;
Raedler, Oliver ;
Wolf, Bernhard ;
Norwig, Jochen ;
Baumann, Knut ;
Alban, Susanne ;
Holzgrabe, Ulrike .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2010, 40 (04) :297-304
[5]   Characterization of Currently Marketed Heparin Products: Reversed-Phase Ion-Pairing Liquid Chromatography Mass Spectrometry of Heparin Digests [J].
Brustkern, Adam M. ;
Buhse, Lucinda F. ;
Nasr, Moheb ;
Al-Hakim, Ali ;
Keire, David A. .
ANALYTICAL CHEMISTRY, 2010, 82 (23) :9865-9870
[6]   The heparin-Ca2+ interaction:: the influence of the O-sulfation pattern on binding [J].
Chevalier, F ;
Lucas, R ;
Angulo, J ;
Martin-Lomas, M ;
Nieto, PM .
CARBOHYDRATE RESEARCH, 2004, 339 (05) :975-983
[7]   Fluorescent DNA-based enzyme sensors [J].
Dai, Nan ;
Kool, Eric T. .
CHEMICAL SOCIETY REVIEWS, 2011, 40 (12) :5756-5770
[8]   Heparin-induced thrombocytopenia: A review [J].
Girolami, Bruno ;
Girolami, Antonio .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2006, 32 (08) :803-809
[9]   Oversulfated chondroitin sulfate is a contaminant in heparin associated with adverse clinical events [J].
Guerrini, Marco ;
Beccati, Daniela ;
Shriver, Zachary ;
Naggi, Annamaria ;
Viswanathan, Karthik ;
Bisio, Antonella ;
Capila, Ishan ;
Lansing, Jonathan C. ;
Guglieri, Sara ;
Fraser, Blair ;
Al-Hakim, Ali ;
Gunay, Nur Sibel ;
Zhang, Zhenqing ;
Robinson, Luke ;
Buhse, Lucinda ;
Nasr, Moheb ;
Woodcock, Janet ;
Langer, Robert ;
Venkataraman, Ganesh ;
Linhardt, Robert J. ;
Casu, Benito ;
Torri, Giangiacomo ;
Sasisekharan, Ram .
NATURE BIOTECHNOLOGY, 2008, 26 (06) :669-675
[10]   A Nanosensor for Ultrasensitive Detection of Oversulfated Chondroitin Sulfate Contaminant in Heparin [J].
Kalita, Mausam ;
Balivada, Sivasai ;
Swarup, Vimal Paritosh ;
Mencio, Caitlin ;
Raman, Karthik ;
Desai, Umesh R. ;
Troyer, Deryl ;
Kuberan, Balagurunathan .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2014, 136 (02) :554-557