Evaluation of the Possibility of Removing Staining by Repolishing Composite Resins Submitted to Artificial Aging

被引:21
作者
de Almeida Anfe, Taciana Emilia [1 ]
Agra, Carlos Martins [2 ]
Vieira, Glauco Fioranelli [3 ]
机构
[1] Sao Paulo State Univ, Dept Restorat Dent, Sao Paulo, SP, Brazil
[2] Univ Ibirapuera, Sao Paulo, Brazil
[3] Univ Sao Paulo, Dept Operat Dent, Sch Dent, Sao Paulo, Brazil
关键词
CIEDE2000; COLOR-DIFFERENCES; FOOD-SIMULATING SOLUTIONS; ONE-STEP SYSTEMS; DELTA-E-ASTERISK; DENTAL COMPOSITES; RESTORATIVE MATERIALS; FLEXURAL STRENGTH; STABILITY; WATER; REPLACEMENT;
D O I
10.1111/j.1708-8240.2011.00435.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This in vitro research verified the possibility of eliminating staining caused by coffee and red wine in five composite resins, after being submitted to thermal cycling. Thirty-six specimens were prepared and immersed in water at 37 degrees C for 24 hours. After polishing, specimen color was measured in a spectrophotometer Cintra 10 UV (Visible Spectrometer, GBC, Braeside, VIC, Australia). All specimens were submitted to thermal cycling at temperatures of 5 and 55 degrees C with a dwell time of 1 minute, for 1,000 cycles in a 75% ethanol/water solution. After thermal cycling, the specimens were immersed in water at 37 degrees C until 7 days had elapsed from the time the specimens were prepared. All specimens were then taken to the spectrophotometer for color measurement. The specimens were divided into three groups (N = 12): distilled water (control), coffee, and red wine. For the staining process to occur on only one surface, all the sides, except one, of the surfaces were isolated with white wax. The specimens were immersed in one of the solutions at 37 degrees C for 14 days. The specimens were dried and taken to the spectrophotometer for color measurement. After this, the specimens were submitted to 20 mu m wear three times, and the color was measured after each one of the wear procedures. Calculation of the color difference was made using CIEDE2000 formula. According to the methodology used in this research, it was concluded that the staining caused by coffee and red wine was superficial and one wear of 20 mu m was sufficient to remove the discoloration.
引用
收藏
页码:260 / 267
页数:8
相关论文
共 53 条
[1]  
Badra VV, 2005, OPER DENT, V30, P213
[2]   Influence of food-simulating solutions and surface finish on susceptibility to staining of aesthetic restorative materials [J].
Bagheri, R ;
Burrow, MF ;
Tyas, M .
JOURNAL OF DENTISTRY, 2005, 33 (05) :389-398
[3]  
Braga Sheila Regina Maia, 2007, Quintessence Int, V38, pe189
[4]  
Burger K M, 1992, J Esthet Dent, V4, P197, DOI 10.1111/j.1708-8240.1992.tb00696.x
[5]   Colour in relation to dentistry. Fundamentals of colour science [J].
Burkinshaw, SM .
BRITISH DENTAL JOURNAL, 2004, 196 (01) :33-41
[6]  
BURKINSHAW SM, 2004, BR DENT J, V196, P29
[7]   THE ABILITY OF FOODS TO STAIN 2 COMPOSITE RESINS [J].
CHAN, KC ;
FULLER, JL ;
HORMATI, AA .
JOURNAL OF PROSTHETIC DENTISTRY, 1980, 43 (05) :542-545
[8]   COLOR DYE FOR IDENTIFICATION OF INCOMPLETELY CURED COMPOSITE RESINS [J].
DEGEE, AJ ;
TENHARKELHAGENAAR, E ;
DAVIDSON, CL .
JOURNAL OF PROSTHETIC DENTISTRY, 1984, 52 (05) :626-631
[9]   Color stability of nanocomposites polished with one-step systems [J].
Erguecue, Z. ;
Tuerkuen, L. S. ;
Aladag, A. .
OPERATIVE DENTISTRY, 2008, 33 (04) :413-420
[10]   Color stability of resin composites after immersion in different drinks [J].
Ertas, Ertan ;
Gueler, Ahmet Umut ;
Yuecel, Ali Cagin ;
Koepruelue, Huelya ;
Gueler, Eda .
DENTAL MATERIALS JOURNAL, 2006, 25 (02) :371-376