Interobserver agreement in intrapartum estimation of fetal head station

被引:68
作者
Buchmann, Eckhart [1 ,2 ]
Libhaber, Elena [2 ,3 ]
机构
[1] Chris Hani Baragwanath Hosp, Dept Obstet & Gynecol, Johannesburg, South Africa
[2] Univ Witwatersrand, Johannesburg, South Africa
[3] Chris Hani Baragwanath Hosp, Dept Cardiol, Johannesburg, South Africa
关键词
intrapartum assessment; fetal head station; interobserver agreement; clinical skills;
D O I
10.1016/j.ijgo.2007.11.020
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To determine interobserver agreement in estimation of fetal head station during tabor, and the determinants of agreement. Methods: A prospective study of fetal head station in 508 women in term tabor. Vaginal examination of station was performed by a researcher at the same time as clinicians performed routine intrapartum assessments of the participants. Station 0 was considered to represent engagement. Results: Station could be estimated by both the researcher and clinicians in 446 women (88%). The kappa statistic for agreement was 0.23 (95% confidence interval, 0.17-0.29). There was agreement in 166 cases (37%) and disagreement by 1 cm in 208 (47%) cases. Agreement was best (50%) when the researcher assessed the head at station minus 1. Multiple regression analysis showed that agreement was not influenced by level of experience of the attending clinicians, nor by obstetric factors. Conclusion: Estimation of station as a method of determining the level of the fetal head in tabor appears imprecise and poorly reproducible. (C) 2008 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:285 / 289
页数:5
相关论文
共 16 条
  • [1] *AAP ACOG, 2002, GUID PER CAR, P1141
  • [2] Accuracy of cervical assessment in the active phase of labour
    Buchmann, E. J.
    Libhaber, E.
    [J]. BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2007, 114 (07) : 833 - 837
  • [3] BUCHMANN EJ, 2007, THESIS U WITWATERSRA
  • [4] CILLIERS JBF, 2003, OBSTET SO AFRICA, P74
  • [5] CRICHTON D, 1974, S AFR MED J, V48, P784
  • [6] Cunningham FG, 2005, WILLIAMS OBSTET, V22nd, P409
  • [7] DEP HLTH, 2002, GUID MAT CAR S AFR M
  • [8] Measuring engagement of the fetal head: validity and reproducibility of a new ultrasound technique
    Dietz, HP
    Lanzarone, V
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 25 (02) : 165 - 168
  • [9] Birth simulator: Reliability of transvaginal assessment of fetal head station as defined by the American College of Obstetricians and Gynecologists classification
    Dupuis, O
    Silveira, R
    Zentner, A
    Dittmar, A
    Gaucherand, P
    Cucherat, M
    Redarce, T
    Rudigoz, R
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2005, 192 (03) : 868 - 874
  • [10] FRIEDMAN EA, 1978, LABOR CLIN EVALUATIO, P37