A point-of-care test for measles diagnosis: detection of measles-specific IgM antibodies and viral nucleic acid

被引:26
作者
Warrener, Lenesha [1 ]
Slibinskas, Rimantas [2 ]
Chua, Kaw Bing [3 ]
Nigatu, Wondatir [4 ]
Brown, Kevin E. [1 ]
Sasnauskas, Kestutis [2 ]
Samuel, Dhanraj [1 ]
Brown, David [1 ]
机构
[1] Hlth Protect Agcy, Ctr Infect, Virus Reference Dept, 61 Colindale Ave, London NW9 5EQ, England
[2] Vilnius Univ, Inst Biotechnol, Vilnius, Lithuania
[3] Natl Publ Hlth Lab, Selangor, Malaysia
[4] Ethiopian Hlth & Nutr Res Inst, Addis Ababa, Ethiopia
关键词
ORAL FLUID SAMPLES; PCR ASSAY; VIRUS; MUMPS; IDENTIFICATION; NUCLEOPROTEIN;
D O I
10.2471/BLT.11.088427
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objective To evaluate the performance of a newly developed point-of-care test (POCT) for the detection of measles-specific IgM antibodies in serum and oral fluid specimens and to assess if measles virus nucleic acid could be recovered from used POCT strips. Methods The POCT was used to test 170 serum specimens collected through measles surveillance or vaccination programmes in Ethiopia, Malaysia and the Russian Federation: 69 were positive for measles immunoglobulin M (IgM) antibodies, 74 were positive for rubella IgM antibodies and 7 were positive for both. Also tested were 282 oral fluid specimens from the measles, mumps and rubella (MMR) surveillance programme of the United Kingdom of Great Britain and Northern Ireland. The Microimmune measles IgM capture enzyme immunoassay was the gold standard for comparison. A panel of 24 oral fluids was used to investigate if measles virus haemagglutinin (H) and nucleocapsid (N) genes could be amplified by polymerase chain reaction directly from used POCT strips. Findings With serum POCT showed a sensitivity and specificity of 90.8% (69/76) and 93.6% (88/94), respectively; with oral fluids, sensitivity and specificity were 90.0% (63/70) and 96.2% (200/208), respectively. Both H and N genes were reliably detected in POCT strips and the N genes could be sequenced for genotyping. Measles virus genes could be recovered from POCT strips after storage for 5 weeks at 20-25 degrees C. Conclusion The POCT has the sensitivity and specificity required of a field-based test for measles diagnosis. However, its role in global measles control programmes requires further evaluation.
引用
收藏
页码:675 / 682
页数:8
相关论文
共 20 条
[1]  
[Anonymous], 2008, Wkly Epidemiol Rec, V83, P229
[2]  
Anonymous, 2009, Morbidity and Mortality Weekly Report, V58, P1321
[3]  
[Anonymous], 2005, BIOPOLYMERS
[4]  
[Anonymous], [No title captured]
[5]  
Centers for Disease Control and Prevention (CDC), 2008, MMWR Morb Mortal Wkly Rep, V57, P657
[6]   The potential for measles transmission in England [J].
Choi, Yoon Hong ;
Gay, Nigel ;
Fraser, Graham ;
Ramsay, Mary .
BMC PUBLIC HEALTH, 2008, 8 (1)
[7]   Development of the Global Measles Laboratory Network [J].
Featherstone, D ;
Brown, D ;
Sanders, R .
JOURNAL OF INFECTIOUS DISEASES, 2003, 187 :S264-S269
[8]  
Jin L, 2002, B WORLD HEALTH ORGAN, V80, P76
[9]   Genetic variability of measles virus in acute and persistent infections [J].
Kuhne, Mirjam ;
Brown, David W. G. ;
Jin, Li .
INFECTION GENETICS AND EVOLUTION, 2006, 6 (04) :269-276
[10]   Measles virus strains circulating in Ethiopia in 1998-1999: Molecular characterisation using oral fluid samples and identification of a new genotype [J].
Nigatu, W ;
Jin, L ;
Cohen, BJ ;
Nokes, DJ ;
Etana, M ;
Cutts, FT ;
Brown, DWG .
JOURNAL OF MEDICAL VIROLOGY, 2001, 65 (02) :373-380