Histological and Histomorphometrical Evaluation of a New Implant Macrogeometry. A Sheep Study

被引:27
作者
Alexandre Gehrke, Sergio [1 ,2 ]
Tumedei, Margherita [3 ]
Aramburu Junior, Jaime [1 ]
Eirles Treichel, Tiago Luis [4 ]
Kolerman, Roni [5 ]
Lepore, Stefania [3 ]
Piattelli, Adriano [3 ]
Iezzi, Giovanna [3 ]
机构
[1] Biotecnos, Dept Res, Cuareim 1483, Montevideo 11100, Uruguay
[2] Univ Catolica Murcia UCAM, Dept Biotechnol, Murcia 30107, Spain
[3] Univ G dAnnunzio, Dept Med Oral & Biotechnol Sci, I-66100 Chieti, Italy
[4] Univ Rio Verde, Dept Surg, Fac Med Vet, BR-75900000 Rio Verde, Brazil
[5] Tel Aviv Univ, Maurice & Gabriela Goldschleger Sch Dent Med, Dept Periodontol & Dent Implantol, IL-6997801 Tel Aviv, Israel
关键词
dental implants; healing chamber; osseointegration; osteogenic matrix; ROOT FORM IMPLANTS; BONE-FORMATION ADJACENT; HEALING CHAMBERS; DENTAL IMPLANTS; IN-VIVO; OSSEOINTEGRATION; TITANIUM; DESIGN; SURFACES;
D O I
10.3390/ijerph17103477
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Decompression or healing chambers between the threads have been proposed to improve and accelerate the osseointegration process of dental implants. The aim of the present work was to test, in an in vivo sheep study, if healing chambers between the threads could produce a better osseointegration process. Thirty titanium implants (15 conventional design (control) and 15 implants with healing chambers (test)) were inserted in a random fashion in the tibia of 3 sheep. The animals were euthanized after 30 days of healing, and the retrieved specimens treated to obtain thin ground sections. Histological observations showed that the quantity of newly formed bone growing in an apical direction was lower in the control group (1095 mu m) when compared to the Test group (1658 mu m). This difference was statistically significant. Moreover, a layer of osteogenic matrix was present around the portion of implants immersed in the marrow spaces. This osteogenic tissue was thicker in the test group. In conclusion, the present study confirmed the very good results in implants with healing chambers that presented a higher percentage of new bone formation.
引用
收藏
页数:13
相关论文
共 34 条
[1]   Early bone formation adjacent to rough and turned endosseous implant surfaces - An experimental study in the dog [J].
Abrahamsson, I ;
Berglundh, T ;
Linder, E ;
Lang, NP ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :381-392
[2]   New Implant Macrogeometry to Improve and Accelerate the Osseointegration: An In Vivo Experimental Study [J].
Alexandre Gehrke, Sergio ;
Aramburu Junior, Jaime ;
Perez-Diaz, Leticia ;
Eirles Treichel, Tiago Luis ;
Dedavid, Berenice Anina ;
De Aza, Piedad N. ;
Carlos Prados-Frutos, Juan .
APPLIED SCIENCES-BASEL, 2019, 9 (15)
[3]   Impact of Different Titanium Implant Thread Designs on Bone Healing: A Biomechanical and Histometric Study with an Animal Model [J].
Alexandre Gehrke, Sergio ;
Eliers Treichel, Tiago Luis ;
Perez-Diaz, Leticia ;
Calvo-Guirado, Jose Luis ;
Aramburu, Jaime, Jr. ;
Mazon, Patricia ;
de Aza, Piedad N. .
JOURNAL OF CLINICAL MEDICINE, 2019, 8 (06)
[4]  
Bertassoni L.E., 2015, ENG MINERALIZED LOAD, V881
[5]   Implant design and its effects on osseointegration over time within cortical and trabecular bone [J].
Beutel, Bryan G. ;
Danna, Natalie R. ;
Granato, Rodrigo ;
Bonfante, Estevam A. ;
Marin, Charles ;
Tovar, Nick ;
Suzuki, Marcelo ;
Coelho, Paulo G. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2016, 104 (06) :1091-1097
[6]  
Bonfante EA, 2011, INT J ORAL MAX IMPL, V26, P75
[7]   The jumping distance revisited - An experimental study in the dog [J].
Botticelli, D ;
Berglundh, T ;
Buser, D ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (01) :35-42
[8]   Enhanced bone apposition to a chemically modified SLA titanium surface [J].
Buser, D ;
Broggini, N ;
Wieland, M ;
Schenk, RK ;
Denzer, AJ ;
Cochran, DL ;
Hoffmann, B ;
Lussi, A ;
Steinemann, SG .
JOURNAL OF DENTAL RESEARCH, 2004, 83 (07) :529-533
[9]   Are insertion torque and early osseointegration proportional? A histologic evaluation [J].
Campos, Felipe E. B. ;
Jimbo, Ryo ;
Bonfante, Estevam A. ;
Barbosa, Darceny Z. ;
Oliveira, Maiolino T. F. ;
Janal, Malvin N. ;
Coelho, Paulo G. .
CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (11) :1256-1260
[10]   Implant design and interface force transfer - A photoelastic and strain-gauge analysis [J].
Cehreli, M ;
Duyck, J ;
De Cooman, M ;
Puers, R ;
Naert, I .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (02) :249-257