Forces and pressures beneath the saddle during mounting from the ground and from a raised mounting platform

被引:27
作者
Geutjens, C. A. [1 ]
Clayton, H. M. [1 ]
Kaiser, L. J. [1 ]
机构
[1] Michigan State Univ, Coll Vet Med, Dept Large Anim Clin Sci, Mary Anne McPhail Performance Ctr, E Lansing, MI 48824 USA
关键词
electronic saddle mat; total force; peak pressure; equestrian; kinetics;
D O I
10.1016/j.tvjl.2007.03.025
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The objective was to use an electronic pressure mat to measure and compare forces and pressures of the saddle on a horse's back when riders mounted from the ground and with the aid of a mounting platform. Ten riders mounted a horse three times each from the ground and from a 35 cm high mounting platform in random order. Total force (summation of forces over all 256 sensors) was measured and compared at specific points on the force-time curve. Total force was usually highest as the rider's right leg was swinging upwards and was correlated with rider mass. When normalized to rider mass, total force and peak pressure were significantly higher when mounting from the ground than from a raised platform (P < 0.05). The area of highest pressure was on the right side of the withers in 97% of mounting efforts, confirming the importance of the withers in stabilizing the saddle during mounting. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:332 / 337
页数:6
相关论文
共 9 条
[1]   Saddle pressure measuring: Validity, reliability and power to discriminate between different saddle-fits [J].
de Cocq, P. ;
van Weeren, P. R. ;
Back, W. .
VETERINARY JOURNAL, 2006, 172 (02) :265-273
[2]   Evaluation of pressure distribution under an English saddle at walk, trot and canter [J].
Fruehwirth, B ;
Peham, C ;
Scheidl, M ;
Schobesberger, H .
EQUINE VETERINARY JOURNAL, 2004, 36 (08) :754-757
[3]  
Harman J, 1999, VET CLIN N AM-EQUINE, V15, P247
[4]   PRACTICAL USE OF A COMPUTERIZED SADDLE PRESSURE MEASURING DEVICE TO DETERMINE THE EFFECTS OF SADDLE PADS ON THE HORSES BACK [J].
HARMAN, JC .
JOURNAL OF EQUINE VETERINARY SCIENCE, 1994, 14 (11) :606-611
[5]  
Harman JC, 1997, PFERDEHEILKUNDE, V13, P129
[6]  
HARRIS SE, 1994, US PONY CLUB MANUAL, P25
[7]   Validity of saddle pressure measurements using force-sensing array technology - Preliminary studies [J].
Jeffcoat, LB ;
Holmes, MA ;
Townsend, HGG .
VETERINARY JOURNAL, 1999, 158 (02) :113-119
[8]   The influence of the width of the saddle tree on the forces and the pressure distribution under the saddle [J].
Meschan, Eva M. ;
Peham, Christian ;
Schobesberger, Hermann ;
Licka, Theresia F. .
VETERINARY JOURNAL, 2007, 173 (03) :578-584
[9]  
Werner D, 2002, PFERDEHEILKUNDE, V18, P125