Assessment of liver viscoelasticity using multifrequency MR elastography

被引:197
作者
Asbach, Patrick [1 ,2 ]
Klatt, Dieter [1 ,2 ]
Hamhaber, Uwe
Braun, Juergen
Somasundaram, Rajan [3 ]
Hamm, Bernd [1 ,2 ]
Sack, Ingolf [1 ,2 ]
机构
[1] Charite Univ Med Berlin, Dept Radiol, D-10117 Berlin, Germany
[2] Charite Univ Med Berlin, Inst Med Informat, D-10117 Berlin, Germany
[3] Charite Univ Med Berlin, Dept Gastroenterol Rheumatol & Infectiol, D-10117 Berlin, Germany
关键词
magnetic resonance elastography; wave speed dispersion; viscoelasticity; liver; cirrhosis; fibrosis; multifrequency MRE;
D O I
10.1002/mrm.21636
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MR elastography (MRE) allows the noninvasive assessment of the viscoelastic properties of human organs based on the organ response to oscillatory shear stress. Shear waves of a given frequency are mechanically introduced and the propagation is imaged by applying motion-sensitive gradients. An experiment was set up that introduces multifrequency shear waves combined with broadband motion sensitization to extend the dynamic range of MRE from one given frequency to, in this study, four different frequencies. With this approach, multiple wave images corresponding to the four driving frequencies are simultaneously acquired and can be evaluated with regard to the dispersion of the complex modulus over the respective frequency. A viscoelastic model based on two shear moduli and one viscosity parameter was used to reproduce the experimental wave speed and wave damping dispersion. The technique was applied in eight healthy volunteers and eight patients with biopsy-proven high-grade liver fibrosis (grade 3-4). Fibrotic liver had a significantly higher (P < 0.01) viscosity (14.4 +/- 6.6 Pa . s) and elastic moduli (2.91 +/- 0.84 kPa; 4.83 +/- 1.77 kPa) than the viscosity (7.3 +/- 2.3 Pa . s) and elastic moduli (1.16 +/- 0.28 kPa; 1.97 +/- 0.30 kPa) of normal volunteers. Multifrequency MRE is well suited for the noninvasive differentiation of normal and fibrotic liver as it allows the measurement of rheologic material properties.
引用
收藏
页码:373 / 379
页数:7
相关论文
共 25 条
[1]   Reversibility of hepatic fibrosis in autoimmune hepatitis [J].
Dufour, JF ;
DeLellis, R ;
Kaplan, MM .
ANNALS OF INTERNAL MEDICINE, 1997, 127 (11) :981-985
[2]   Liver fibrosis - from bench to bedside [J].
Friedman, SL .
JOURNAL OF HEPATOLOGY, 2003, 38 :S38-S53
[3]   Regression of liver fibrosis after biliary drainage in patients with chronic pancreatitis and stenosis of the common bile duct [J].
Hammel, P ;
Couvelard, A ;
O'Toole, D ;
Ratouis, A ;
Sauvanet, A ;
Fléjou, JF ;
Degott, C ;
Belghiti, J ;
Bernades, P ;
Valla, D ;
Ruszniewski, P ;
Lévy, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (06) :418-423
[4]   Liver fibrosis: non-invasive assessment with MR elastography [J].
Huwart, L ;
Peeters, F ;
Sinkus, R ;
Annet, L ;
Salameh, N ;
ter Beek, LC ;
Horsmans, Y ;
Van Beers, BE .
NMR IN BIOMEDICINE, 2006, 19 (02) :173-179
[5]   Viscoelastic characterization of in vitro canine tissue [J].
Kiss, MZ ;
Varghese, T ;
Hall, TJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (18) :4207-4218
[6]   Noninvasive assessment of the rheological behavior of human organs using multifrequency MR elastography: a study of brain and liver viscoelasticity [J].
Klatt, Dieter ;
Hamhaber, Uwe ;
Asbach, Patrick ;
Braun, Juergen ;
Sack, Ingolf .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (24) :7281-7294
[7]   In vivo determination of hepatic stiffness using steady-state free precession magnetic resonance elastography [J].
Klatt, Dieter ;
Asbach, Patrick ;
Rump, Jens ;
Papazoglou, Sebastian ;
Somasundaram, Rajan ;
Modrow, Jens ;
Braun, Juergen ;
Sack, Ingolf .
INVESTIGATIVE RADIOLOGY, 2006, 41 (12) :841-848
[8]   Tissue characterization using magnetic resonance elastography: preliminary results [J].
Kruse, SA ;
Smith, JA ;
Lawrence, AJ ;
Dresner, MA ;
Manduca, A ;
Greenleaf, JF ;
Ehman, RL .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (06) :1579-1590
[9]  
Liu Z, 2000, BIORHEOLOGY, V37, P191
[10]  
Manduca A., 2003, P 11 ANN M ISMRM TOR