The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty - Examining the successes and failures

被引:123
作者
Berend, KR
Lombardi, AV
Mallory, TH
Adams, JB
Russell, JH
Groseth, KL
机构
[1] Joint Implant Surgeons Inc, Columbus, OH 43215 USA
[2] Ohio State Univ, Dept Orthopaed, Columbus, OH 43210 USA
[3] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
[4] New Albany Surg Hosp, Dept Surg, New Albany, OH USA
关键词
total hip arthroplasty; constrained acetabular components; dislocation;
D O I
10.1016/j.arth.2005.06.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Constrained acetabular components can treat or prevent instability after total hip arthroplasty (THA). We examine long-term results of 755 consecutive constrained THA in 720 patients (1986-1993; 62 primary, 59 conversion, 565 revision, 60 reimplantation, and 9 total femur). Eighty-three patients (88THAs) were lost before 10-year follow-tip, leaving 639 patients (667 THAs) available for Study. Dislocation occurred in 117 hips (17.5%), in 37 (28.9%) of 128 constrained for recurrent dislocation, and 46 (28.2%) of 163 with dislocation history. Other reoperations were for aseptic loosening (51, 7.6% acetabular; 28, 4.2% stem; 16, 2.4% combined), infection (40, 6.0%), periprosthetic fracture (19, 2.8%), stem breakage (2, 0.3%), cup malposition (1, 0.1%), dissociated insert (1, 0.1%), dissociated femoral head (1, 0.1%), and impingement of I broken (0.1%) and 4 (0.6%) dissociated constraining rings. Although constrained acetabular components prevented recurrent dislocation in 71.1%, they should be used cautiously, with a 42.1% long-term failure rate observed in this series. Dislocation was common despite constraint with previous history as a significant risk.
引用
收藏
页码:93 / 102
页数:10
相关论文
共 49 条
[21]  
Fisher D A, 1994, J Arthroplasty, V9, P325, DOI 10.1016/0883-5403(94)90088-4
[22]   REVISION OF THE CHARNLEY LOW-FRICTION ARTHROPLASTY FOR RECURRENT OR IRREDUCIBLE DISLOCATION [J].
FRASER, GA ;
WROBLEWSKI, BM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1981, 63 (04) :552-555
[23]   Salvage of a recurrently dislocating total hip prosthesis with use of a constrained acetabular component - A retrospective analysis of fifty-six cases [J].
Goetz, DD ;
Capello, WN ;
Callaghan, JJ ;
Brown, TD ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (04) :502-509
[24]  
GOETZ DD, 1998, CLIN ORTHOP RELAT R, V355, P171
[25]  
James SP, 1999, J BIOMED MATER RES, V48, P374, DOI 10.1002/(SICI)1097-4636(1999)48:3<374::AID-JBM23>3.0.CO
[26]  
2-O
[27]   Failure of a constrained acetabular prosthesis of a total hip arthroplasty - A report of four cases [J].
Kaper, BP ;
Bernini, PM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (04) :561-565
[28]   Backside nonconformity and locking restraints affect liner shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement [J].
Kurtz, SM ;
Ochoa, JA ;
White, CV ;
Srivastav, S ;
Cournoyer, J .
JOURNAL OF BIOMECHANICS, 1998, 31 (05) :431-437
[29]  
Lachiewicz Paul F, 2002, J Am Acad Orthop Surg, V10, P233
[30]   Stability of total hip arthroplasty in patients 75 years or older [J].
Lachiewicz, PF ;
Soileau, ES .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (405) :65-69