Flow Injection Analysis of Ethambutol in Antituberculosis Drugs Using a Graphite-Paraffin Electrode as Amperometric Detector

被引:11
作者
Perantoni, Camila Bellei [1 ]
Soares Carbogim, Luis Gustavo [1 ]
Semaan, Felipe Silva [2 ]
Matos, Renato Camargo [1 ]
Lowinsohn, Denise [1 ]
机构
[1] Univ Fed Juiz de Fora, NUPIS Nucleo Pesquisa Instrumentacao & Separacoe, Dept Quim, Inst Ciencias Exatas, BR-36036330 Juiz De Fora, MG, Brazil
[2] Univ Fed Fluminense, Inst Quim, Dept Quim Analit, BR-24020150 Niteroi, RJ, Brazil
关键词
Antituberculosis drugs; Carbon-based composite electrode; Ethambutol; FIA; PERFORMANCE LIQUID-CHROMATOGRAPHY; PRECOLUMN DERIVATIZATION; UV DETECTION; HUMAN PLASMA; ELECTROPHORESIS; HYDROCHLORIDE; SPECTROMETRY; TABLETS; SYSTEM;
D O I
10.1002/elan.201100195
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A graphite-paraffin composite electrode has been used for the determination of ethambutol, an antituberculosis drug, in pharmaceutical samples by anodic oxidation. Voltammetric studies were used to characterise the electro-chemical behaviour of the ethambutol in different pH solutions (3.0, 8.0 and 12.0). Quantification was carried out using amperometric detection. The detector was assembled in a flow injection apparatus and operated at + 1.1 V (vs. Ag/ AgCl(NaCl, sat)). The conditions for the best electrode's response were determined by studying the influence of sample volume and flow rate. The linear response for the method was extended up to a 1.5 mmolL(-1) ethambutol solution with a detection limit of 0.1 mmolL(-1). The repeatability for successive injections of 1.0 mmolL(-1) ethambutol solution was 0.9% (n = 26), demonstrating a good performance of the developed amperometric sensor. The analytical frequency was calculated as approximately 47 determinations h(-1). Two different commercial samples were successfully analysed and the results were in good agreement with those obtained by using spectrophotometry. The advantages of the proposed amperometric method over the reference method include simplicity, low consumption of reagents and increased analytical frequency.
引用
收藏
页码:2582 / 2585
页数:4
相关论文
共 25 条
[21]  
SHINGBAL DM, 1982, J ASSOC OFF ANA CHEM, V65, P899
[22]  
Silva J. A. F., 2010, ELECTROPHORESIS, V31, P570
[23]  
TAWAKKOL MS, 1978, PHARMAZIE, V33, P85
[24]   Determination of ethambutol hydrochloride in the combination tablets by precolumn derivatization [J].
Yan, Ming ;
Guo, Tao ;
Song, Hongtao ;
Zhao, Qingchun ;
Sui, Yin .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2007, 45 (05) :269-272
[25]  
Zhang YN, 2002, CHINESE J ANAL CHEM, V30, P857