Flow Injection Analysis of Ethambutol in Antituberculosis Drugs Using a Graphite-Paraffin Electrode as Amperometric Detector

被引:11
作者
Perantoni, Camila Bellei [1 ]
Soares Carbogim, Luis Gustavo [1 ]
Semaan, Felipe Silva [2 ]
Matos, Renato Camargo [1 ]
Lowinsohn, Denise [1 ]
机构
[1] Univ Fed Juiz de Fora, NUPIS Nucleo Pesquisa Instrumentacao & Separacoe, Dept Quim, Inst Ciencias Exatas, BR-36036330 Juiz De Fora, MG, Brazil
[2] Univ Fed Fluminense, Inst Quim, Dept Quim Analit, BR-24020150 Niteroi, RJ, Brazil
关键词
Antituberculosis drugs; Carbon-based composite electrode; Ethambutol; FIA; PERFORMANCE LIQUID-CHROMATOGRAPHY; PRECOLUMN DERIVATIZATION; UV DETECTION; HUMAN PLASMA; ELECTROPHORESIS; HYDROCHLORIDE; SPECTROMETRY; TABLETS; SYSTEM;
D O I
10.1002/elan.201100195
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A graphite-paraffin composite electrode has been used for the determination of ethambutol, an antituberculosis drug, in pharmaceutical samples by anodic oxidation. Voltammetric studies were used to characterise the electro-chemical behaviour of the ethambutol in different pH solutions (3.0, 8.0 and 12.0). Quantification was carried out using amperometric detection. The detector was assembled in a flow injection apparatus and operated at + 1.1 V (vs. Ag/ AgCl(NaCl, sat)). The conditions for the best electrode's response were determined by studying the influence of sample volume and flow rate. The linear response for the method was extended up to a 1.5 mmolL(-1) ethambutol solution with a detection limit of 0.1 mmolL(-1). The repeatability for successive injections of 1.0 mmolL(-1) ethambutol solution was 0.9% (n = 26), demonstrating a good performance of the developed amperometric sensor. The analytical frequency was calculated as approximately 47 determinations h(-1). Two different commercial samples were successfully analysed and the results were in good agreement with those obtained by using spectrophotometry. The advantages of the proposed amperometric method over the reference method include simplicity, low consumption of reagents and increased analytical frequency.
引用
收藏
页码:2582 / 2585
页数:4
相关论文
共 25 条
  • [1] CHEMICAL CHARACTERIZATION OF ETHAMBUTOL BINDING TO MYCOBACTERIUM-SMEGMATIS
    BEGGS, WH
    ANDREWS, FA
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1974, 5 (03) : 234 - 239
  • [2] Determination of ethambutol in human plasma and urine by high-performance liquid chromatography with fluorescence detection
    Breda, M
    Marrari, P
    Pianezzola, E
    Benedetti, MS
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 729 (1-2) : 301 - 307
  • [3] Chen S., 2008, CHEM ANAL-WARSAW, V53, P511
  • [4] Determination of ethambutol in plasma by high-performance liquid chromatography after pre-column derivatization
    Chenevier, P
    Massias, L
    Gueylard, D
    Farinotti, R
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1998, 708 (1-2): : 310 - 315
  • [5] Elazazy Marwa S., 2004, Chinese Pharmaceutical Journal (Taipei), V56, P37
  • [6] Optimization of an electrolyte system for analysis of ethambutol in pharmaceutical formulations by capillary zone electrophoresis using complexation with copper(II)
    Faria, Adriana F.
    de Souza, Marcus V. N.
    Bruns, Roy E.
    de Oliveira, Marcone A. L.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1202 (02) : 224 - 228
  • [7] Ethambutol Analysis by Copper Complexation in Pharmaceutical Formulations: Spectrophotometry and Crystal Structure
    Faria, Adriana F.
    Marcellos, Luiza F.
    Vasconcelos, Juliana P.
    de Souza, Marcus V. N.
    Junior, Antonio L. S.
    do Carmo, Weberton R.
    Diniz, Renato
    de Oliveira, Marcone A. L.
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2011, 22 (05) : 867 - U81
  • [8] Simultaneous determination of first-line anti-tuberculosis drugs by capillary zone electrophoresis using direct UV detection
    Faria, Adriana F.
    de Souza, Marcus V. N.
    Bruns, Roy E.
    de Oliveira, Marcone A. L.
    [J]. TALANTA, 2010, 82 (01) : 333 - 339
  • [9] ION-PAIR EXTRACTION AND PRECIPITATION METHODS FOR ETHAMBUTOL DETERMINATION
    GIRGIS, EH
    GAD, Z
    MARAM, M
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 1974, 63 (11) : 1764 - 1769
  • [10] A rapid and robust liquid chromatography/tandem mass spectrometry method for simultaneous analysis of anti-tuberculosis drugs-Ethambutol and pyrazinamide in human plasma
    Gong, Zhilong
    Basir, Yousef
    Chu, David
    McCort-Tipton, Melanie
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (16-17): : 1698 - 1704