Changes in lung volume and upper airway using MRI during application of nasal expiratory positive airway pressure in patients with sleep-disordered breathing

被引:25
作者
Braga, C. W. [2 ]
Chen, Q. [1 ]
Burschtin, O. E. [1 ]
Rapoport, D. M. [1 ]
Ayappa, I. [1 ]
机构
[1] NYU, Sch Med, Div Pulm Crit Care & Sleep Med, New York, NY 10016 USA
[2] Univ Fed Rio Grande do Sul, Porto Alegre, RS, Brazil
关键词
obstructive sleep apnea; obstructive sleep apnea therapy; resistance valves; tracheal traction; EPAP DEVICE; APNEA; COLLAPSIBILITY; ADHERENCE; MEN; CO2;
D O I
10.1152/japplphysiol.00218.2011
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Braga CW, Chen Q, Burschtin OE, Rapoport DM, Ayappa I. Changes in lung volume and upper airway using MRI during application of nasal expiratory positive airway pressure in patients with sleep-disordered breathing. J Appl Physiol 111: 1400-1409, 2011. First published July 28, 2011; doi:10.1152/japplphysiol.00218.2011.-Nasal expiratory positive airway pressure (nEPAP) delivered with a disposable device (Provent, Ventus Medical) has been shown to improve sleep-disordered breathing (SDB) in some subjects. Possible mechanisms of action are 1) increased functional residual capacity (FRC), producing tracheal traction and reducing upper airway (UA) collapsibility, and 2) passive dilatation of the airway by the expiratory pressure, carrying over into inspiration. Using MRI, we estimated change in FRC and ventilation, as well as UA cross-sectional area (CSA), in awake patients breathing on and off the nEPAP device. Ten patients with SDB underwent nocturnal polysomnography and MRI with and without nEPAP. Simultaneous images of the lung and UA were obtained at 6 images/s. Image sequences were obtained during mouth and nose breathing with and without the nEPAP device. The nEPAP device produced an end-expiratory pressure of 4-17 cmH(2)O. End-tidal PCO(2) rose from 39.7 +/- 5.3 to 47.1 +/- 6.0 Torr (P < 0.01). Lung volume changes were estimated from sagittal MRI of the right lung. Changes in UA CSA were calculated from transverse MRI at the level of the pharynx above the epiglottis. FRC determined by MRI was well correlated to FRC determined by N(2) washout (r = 0.76, P = 0.03). nEPAP resulted in a consistent increase in FRC (46 +/- 29%, P < 0.001) and decrease in ventilation (50 +/- 15%, P < 0.001), with no change in respiratory frequency. UA CSA at end expiration showed a trend to increase. During wakefulness, nEPAP caused significant hyperinflation, consistent with an increase in tracheal traction and a decrease in UA collapsibility. Direct imaging effects on the UA were less consistent, but there was a trend to dilatation. Finally, we showed significant hypoventilation and rise in PCO(2) during use of the nEPAP device during wakefulness and sleep. Thus, at least three mechanisms of action have the potential to contribute to the therapeutic effect of nEPAP on SDB.
引用
收藏
页码:1400 / 1409
页数:10
相关论文
共 24 条
  • [1] A Novel Nasal Expiratory Positive Airway Pressure (EPAP) Device for the Treatment of Obstructive Sleep Apnea: A Randomized Controlled Trial
    Berry, Richard B.
    Kryger, Meir H.
    Massie, Clifford A.
    [J]. SLEEP, 2011, 34 (04) : 479 - 485
  • [2] Measurement of absolute lung volumes by imaging techniques
    Clausen, J
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (10) : 2427 - 2431
  • [3] Colrain IM, 2008, J CLIN SLEEP MED, V4, P426
  • [4] Epstein LJ, 2009, J CLIN SLEEP MED, V5, P263
  • [5] Effect of expiratory positive airway pressure on sleep disordered breathing
    Heinzer, Raphael
    White, David P.
    Malhotra, Atul
    Lo, Yu L.
    Dover, Louise
    Stevenson, Karen E.
    Jordan, Amy S.
    [J]. SLEEP, 2008, 31 (03) : 429 - 432
  • [6] Classification of sleep-disordered breathing
    Hosselet, JJ
    Ayappa, I
    Norman, RG
    Krieger, AC
    Rapoport, DM
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 163 (02) : 398 - 405
  • [7] MECHANICS OF THE RESPIRATORY SYSTEM AND BREATHING PATTERN DURING SLEEP IN NORMAL HUMANS
    HUDGEL, DW
    MARTIN, RJ
    JOHNSON, B
    HILL, P
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1984, 56 (01) : 133 - 137
  • [8] Iber C, 2007, ASM MANUAL SCORING S
  • [9] The effects of body mass index on lung volumes
    Jones, Richard L.
    Nzekwu, Mary-Magdalene U.
    [J]. CHEST, 2006, 130 (03) : 827 - 833
  • [10] Genioglossal muscle response to CO2 stimulation during NREM sleep
    Lo, YL
    Jordan, AS
    Malhotra, A
    Wellman, A
    Heinzer, RC
    Schory, K
    Dover, L
    Fogel, RB
    White, DP
    [J]. SLEEP, 2006, 29 (04) : 470 - 477