Changes in visual quality with soft contact lenses after the instillation of hyaluronic acid eye drops

被引:2
作者
Carpena-Torres, Carlos [1 ]
Pastrana, Cristina [1 ]
Rodriguez-Pomar, Candela [1 ]
Serramito, Maria [1 ]
Batres, Laura [1 ]
Carracedo, Gonzalo [1 ]
机构
[1] Univ Complutense Madrid, Fac Opt & Optometry, Dept Optometry & Vis, Ocupharm Res Grp, Madrid, Spain
关键词
Eye drops; Visual quality; Contact lens; Hyaluronic acid; SODIUM HYALURONATE; OPTICAL-QUALITY; CLICK CHEMISTRY; DRY; MANAGEMENT; EFFICACY; TEAR; ABERRATIONS; DIQUAFOSOL; IMPROVE;
D O I
10.1016/j.clae.2021.101471
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the changes in visual function and anterior surface aberrations during soft contact lens (SCL) wear after the instillation of hyaluronic acid (HA) eye drops with different viscosity. Methods: A prospective, randomized, and participant-masked study was performed. Twenty healthy participants (25.4 +/- 2.6 years) were evaluated. Hydrogel (Ocufilcon D) and silicone-hydrogel (Somofilcon A) SCL were randomly assigned to both eyes of the same participant. Visual function in terms of high- and low-contrast corrected distance visual acuity (CDVA) and anterior contact lens surface aberrations (RMS HOA) were measured before and after the instillation, at different times, of different eye drops: saline (control) and 0.1%, 0.2%, and 0.3% HA. Results: Compared with the saline solution, during hydrogel SCL wear, there was an improvement (P < 0.05) in high-contrast CDVA after 3 and 10 min with 0.1% HA, and after 5 and 20 min with 0.2% HA. During silicone-hydrogel SCL wear, there was a deterioration (P < 0.05) in high-contrast CDVA after 1 and 30 min with 0.3% HA. Additionally, during silicone-hydrogel SCL wear, there was also a deterioration (P < 0.05) in low-contrast CDVA after 5 and 20 min with 0.3% HA. In terms of RMS HOA, there were no clinically relevant changes with both SCL. Conclusions: The instillation of HA eye drops could have a different effect on visual quality depending on their concentration of HA, the contact lens material, its surface ionicity, or other physicochemical properties that should be studied in future studies.
引用
收藏
页数:7
相关论文
共 33 条
  • [1] Objective and subjective assessing efficacy of a lubricating drop in eyes wearing silicone hydrogel contact lenses
    Asharlous, Amir
    Mirzajani, Ali
    Jafarzadehpur, Ebrahim
    KhabazKhoob, Mehdi
    Ostadimoghaddam, Hadi
    [J]. JOURNAL OF CURRENT OPHTHALMOLOGY, 2016, 28 (02): : 69 - 74
  • [2] Randomized, phase III study comparing osmoprotective carboxymethylcellulose with sodium hyaluronate in dry eye disease
    Baudouin, Christophe
    Cochener, Beatrice
    Pisella, Pierre-Jean
    Girard, Brigitte
    Pouliquen, Pascale
    Cooper, Hazel
    Creuzot-Garcher, Catherine
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (05) : 751 - 761
  • [3] Evaluation of tear meniscus by optical coherence tomography after different sodium hyaluronate eyedrops instillation
    Carracedo, Gonzalo
    Pastrana, Cristina
    Serramito, Maria
    Rodriguez-Pomar, Candela
    [J]. ACTA OPHTHALMOLOGICA, 2019, 97 (02) : E162 - E169
  • [4] Comparison Between Viscous Teardrops and Saline Solution to Fill Orthokeratology Contact Lenses Before Overnight Wear
    Carracedo, Gonzalo
    Villa-Collar, Cesar
    Martin-Gil, Alba
    Serramito, Maria
    Santamaria, Leticia
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S307 - S311
  • [5] "Click" Chemistry-Tethered Hyaluronic Acid-Based Contact Lens Coatings Improve Lens Wettability and Lower Protein Adsorption
    Deng, Xudong
    Korogiannaki, Myrto
    Rastegari, Banafsheh
    Zhang, Jianfeng
    Chen, Mengsu
    Fu, Qiang
    Sheardown, Heather
    Filipe, Carlos D. M.
    Hoare, Todd
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2016, 8 (34) : 22064 - 22073
  • [6] Diquafosol Delivery from Silicone Hydrogel Contact Lenses: Improved Effect on Tear Secretion
    Dominguez-Godinez, Carmen
    Carracedo, Gonzalo
    Pintor, Jesus
    [J]. JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS, 2018, 34 (1-2) : 170 - 176
  • [7] Dominguez-Godinez CO., 2013, J Optom, V6, P205, DOI [10.1016/j.optom.2013.07.004, DOI 10.1016/J.OPTOM.2013.07.004]
  • [8] Guillon Michel, 2004, Eye Contact Lens, V30, P34, DOI 10.1097/01.ICL.0000101489.13687.9A
  • [9] TFOS DEWS II Management and Therapy Report
    Jones, Lyndon
    Downie, Laura E.
    Korb, Donald
    Benitez-del-Castillo, Jose M.
    Dana, Reza
    Deng, Sophie X.
    Dong, Pham N.
    Geerling, Gerd
    Hida, Richard Yudi
    Liu, Yang
    Seo, Kyoung Yul
    Tauber, Joseph
    Wakamatsu, Tais H.
    Xu, Jianjiang
    Wolffsohn, James S.
    Craig, Jennifer P.
    [J]. OCULAR SURFACE, 2017, 15 (03) : 575 - 628
  • [10] The TFOS International Workshop on Contact Lens Discomfort: Report of the Contact Lens Materials, Design, and Care Subcommittee
    Jones, Lyndon
    Brennan, Noel A.
    Gonzalez-Meijome, Jose
    Lally, John
    Maldonado-Codina, Carole
    Schmidt, Tannin A.
    Subbaraman, Lakshman
    Young, Graeme
    Nichols, Jason J.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (11) : 37 - 70