Air-oxygen mixtures in circle systems

被引:8
作者
Hendrickx, JFA [1 ]
De Cooman, S [1 ]
Vandeput, DM [1 ]
Van Alphen, J [1 ]
Coddens, J [1 ]
Deloof, T [1 ]
De Wolf, AM [1 ]
机构
[1] Northwestern Univ, Sch Med, Dept Anesthesiol, Chicago, IL 60611 USA
关键词
air; oxygen; anesthesia techniques; low-flow anesthesia; circle system; patient safety;
D O I
10.1016/S0952-8180(01)00303-8
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Study Objective: To determine the effect of different air-O-2 mixtures and fresh gas flows F (FGF) on the relationship between the delivered (FDelO2) and inspired O-2 fraction (FIO2) in a circle system. Study Design: Randomized clinical study. Setting: Large teaching hospital. Patients: 160 ASA physical status I, II, and III patients undergoing a variety of cardiovascular procedures with general endotracheal anesthesia. Interventions: 160 Patients were randomly assigned to one of 20 groups (n = 8 each), depending on the combination of total FGF (0.5, 1, 2, 4, or 8 L/min) and air-O-2 mixture used (ratios of 4/1, 3/2, 2/3, or 1/4), corresponding to a FDelO2 of 0.37, 0.53, 0.68, and 0.84. For each combination of FGF and air-O-2 mixture, FIO2 after equilibration was compared with FDelO2. Measurements and Main Results: With any air-O-2 mixture with a FGF less than or equal to 2 L/min, FIO2 became lower than FDelO2. Because FIO2 decreased below 0.25 after 13 and 26 minutes in the first two Patients of the 4/1 0.5 L/min air-O-2 group, this study limb was terminated. Conclusions: When using air-O-2 mixtures in a circle system, FIO2 becomes lower than the FDelO2 with FGF less than or equal to 2 L/min. The relative proportion of 02 in the FGF has to be increased accordingly. (C) 2001 by Elsevier Science Inc.
引用
收藏
页码:461 / 464
页数:4
相关论文
共 10 条
[1]  
BAUM JA, 1996, LOW FLOW ANAESTHESIA, P26
[2]   SAMPLED GAS NEED NOT BE RETURNED DURING LOW-FLOW ANESTHESIA [J].
BENGTSON, JP ;
BENGTSSON, J ;
BENGTSSON, A ;
STENQVIST, O .
JOURNAL OF CLINICAL MONITORING, 1993, 9 (05) :330-334
[3]  
Dorsch JA, 1994, UNDERSTANDING ANESTH, P51
[4]  
EISENKRAFT JB, 1993, ANESTHESIA EQUIPMENT, P27
[5]   Influence of the reference gas of paramagnetic oxygen analyzers on nitrogen concentrations during closed-circuit anesthesia [J].
Hendrickx, JFA ;
van Zundert, AAJ ;
de Wolf, AM .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1998, 14 (06) :381-384
[6]   PERFORMANCE AND APPLICATION OF QUANTIFLEX AIR-OXYGEN MIXER [J].
RICHARDSON, FJ ;
CHINN, S ;
NUNN, JF .
BRITISH JOURNAL OF ANAESTHESIA, 1976, 48 (11) :1057-1064
[7]  
SCHILLIG R, 1973, ANAESTHESIST, V22, P198
[8]  
Schoenmakers B, 2000, ANESTH ANALG, V90, pU143
[9]   MINIMAL-FLOW NITROUS-OXIDE ANESTHESIA [J].
VIRTUE, RW .
ANESTHESIOLOGY, 1974, 40 (02) :196-198
[10]  
WESTENSKOW D R, 1986, International Journal of Clinical Monitoring and Computing, V2, P187, DOI 10.1007/BF02915886