Non-Contact Measurement of Small-Module Gears Using Optical Coherence Tomography

被引:6
作者
Luo, Manting [1 ,2 ]
Zhong, Shuncong [1 ,3 ]
机构
[1] Fuzhou Univ, Sch Mech Engn & Automat, Lab Opt Terahertz & Nondestruct Testing, Fuzhou 350108, Fujian, Peoples R China
[2] Putian Univ, Sch Mech & Elect Engn, Putian 351100, Peoples R China
[3] Shanghai Univ, Sch Mechatron Engn & Automat, Shanghai 200072, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2018年 / 8卷 / 12期
基金
中国国家自然科学基金;
关键词
small-module gear; non-contact measurement; optical coherence tomography; high accuracy; REPRODUCIBILITY; REPEATABILITY; THICKNESS;
D O I
10.3390/app8122490
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Due to the small size and harsh transmission conditions of small-module gears, it is very difficult to measure gear characteristics with a modulus smaller than 1 mm. We proposed an optical coherence tomography (OCT) method for measuring small-module gears. Testing of a 30-tooth copper gear with a small modulus of 0.5 mm was carried out for the measurement of its modulus, tooth parameter, tooth number, pressure angle, modification coefficient, and tooth thickness by using OCT. In addition, the influencing factors on the measurement were discussed. The whole teeth profile of a 0.2 mm modulus gear was imaged by processing of the data collected from different clamping angles. Compared with the visual imaging without depth information and small-scale microscopic imaging, the OCT method has shown its superiority, and it has potential in the application of the measurement of micro gears with a small modulus of less than 0.2 mm.
引用
收藏
页数:12
相关论文
共 22 条
[1]  
Chinese National Standard, 1987, 13571987 GBT CHIN NA
[2]  
Chinese National Standard, 1990, 236290 GB CHIN NAT S
[3]   Application of optical coherence tomography to automated contact lens metrology [J].
Davidson, Bryan R. ;
Barton, Jennifer K. .
JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (01)
[4]  
Feng G., 2007, TOOL ENG, V41, P3
[5]   Gear metrology [J].
Goch, G .
CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2003, 52 (02) :659-695
[6]  
Hongru Du, 2011, 2011 International Conference on Multimedia and Signal Processing (CMSP), P243, DOI 10.1109/CMSP.2011.56
[7]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[8]  
International Organization for Standardization, 1999, 90002000 BS EN ISO
[9]  
Isao X., 2003, P PRECIS ENG SOC, V69, P3
[10]   Scan-Less Line Field Optical Coherence Tomography, with Automatic Image Segmentation, as a Measurement Tool for Automotive Coatings [J].
Lawman, Samuel ;
Williams, Bryan M. ;
Zhang, Jinke ;
Shen, Yao-Chun ;
Zheng, Yalin .
APPLIED SCIENCES-BASEL, 2017, 7 (04)