Predicting the Size of a Left Double-Lumen Tube for Asian Women Based on the Combination of the Diameters of the Cricoid Ring and Left Main Bronchus: A Randomized, Prospective, Controlled Trial

被引:16
作者
Liu Shiqing [1 ]
Qi Wenxu [2 ]
Mao Yuqiang [3 ]
Dong Youjing [1 ]
机构
[1] China Med Univ, Shengjing Hosp, Dept Anesthesiol, Shenyang, Peoples R China
[2] China Med Univ, Shengjing Hosp, Dept Radiol, Shenyang, Peoples R China
[3] China Med Univ, Shengjing Hosp, Dept Thorac Surg, Shenyang, Peoples R China
关键词
ONE-LUNG VENTILATION; ENDOBRONCHIAL TUBES; DIMENSIONS; PLACEMENT; INJURIES; CADAVER; BLOCKER;
D O I
10.1213/ANE.0000000000003839
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: There are limited data about how to choose the correct size of a double-lumen tube (DLT). It is especially difficult to select an appropriate DLT for Asian women because of their small stature. The primary aim of this study was to compare the overall accuracy of the DLT selected based on the combination of transverse diameter of cricoid ring and the equivalent diameter of the left main bronchus (ED-LMB) with that based on the ED-LMB alone for Asian women. METHODS: In this study, 80 consecutive and blinded female patients were assigned randomly to 2 groups. The overall accuracy of the selection of DLT was compared between the Combined group and LMB group. The accuracy of the selection of tracheal segment and bronchial segment was also compared between the 2 groups. The postoperative hoarseness and sore throat were investigated by blinded assessors. RESULTS: The overall accuracy of selection of the DLTs was higher in the Combined group than that in the LMB group (87.5% vs 60.0%; P = .010). The accuracy of selection of tracheal segment was also higher in the Combined group (92.5% vs 67.5%; P = .010). The accuracy of selection of bronchial segment was similar between the groups (95.0 % vs 86.1%; P = .246). The severity of sore throat was higher in the LMB group at 24 hours after the operation (P = .001). CONCLUSIONS: The correct size of DLT for Asian women should be selected based on the combination of transverse diameter of cricoid ring and the ED-LMB.
引用
收藏
页码:762 / 768
页数:7
相关论文
共 25 条
[1]   Tracheal diameter predicts double-lumen tube size: A method for selecting left double-lumen tubes [J].
Brodsky, JB ;
Macario, A ;
Mark, JBD .
ANESTHESIA AND ANALGESIA, 1996, 82 (04) :861-864
[2]  
BRODSKY JB, 1991, ANESTH ANALG, V73, P570
[3]   Tracheal width and teft double-lumen tube size: a formula to estimate teft-bronchial width [J].
Brodsky, JB ;
Lemmens, HJM .
JOURNAL OF CLINICAL ANESTHESIA, 2005, 17 (04) :267-270
[4]   Which device should be considered the best for lung isolation: double-lumen endotracheal tube versus bronchial blockers [J].
Campos, Javier H. .
CURRENT OPINION IN ANESTHESIOLOGY, 2007, 20 (01) :27-31
[5]   Predicting the size of a double-lumen endobronchial tube based on tracheal diameter [J].
Chow, MYH ;
Liam, BL ;
Lew, TWK ;
Chelliah, RY ;
Ong, BC .
ANESTHESIA AND ANALGESIA, 1998, 87 (01) :158-160
[6]   Predicting the size of a double-lumen endobronchial tube using computed tomographic scan measurements of the left main bronchus diameter [J].
Chow, MYH ;
Liam, BL ;
Thng, CH ;
Chong, BK .
ANESTHESIA AND ANALGESIA, 1999, 88 (02) :302-305
[7]   DIFFICULT TRACHEAL INTUBATION IN OBSTETRICS [J].
CORMACK, RS ;
LEHANE, J .
ANAESTHESIA, 1984, 39 (11) :1105-1111
[8]   Evaluation of an approach to choosing a left double-lumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter [J].
Hannallah, M ;
Benumof, JL ;
Silverman, PM ;
Kelly, LC ;
Lea, D .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1997, 11 (02) :168-171
[9]  
Ideris SS, 2017, ANN CARD ANAESTH, V20, P28, DOI 10.4103/0971-9784.197824
[10]   Measurements of the Length and Diameter of Main Bronchi on Three-Dimensional Images in Asian Adult Patients in Comparison With the Height of Patients [J].
Kim, Deokkyu ;
Son, Ji-Seon ;
Ko, Seonghoon ;
Jeong, Woojoo ;
Lim, Hyungsun .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2014, 28 (04) :890-895