Performances of VITEK 2 colorimetric cards for identification of gram-positive and gram-negative bacteria

被引:34
作者
Wallet, F [1 ]
Loïez, C [1 ]
Renaux, E [1 ]
Lemaitre, N [1 ]
Courcol, RJ [1 ]
机构
[1] CHU Lille, Lab Bacteriol Hyg, F-59037 Lille, France
关键词
D O I
10.1128/JCM.43.9.4402-4406.2005
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The purpose of this study was to evaluate the new VITEK 2 identification cards that use colorimetric reading to identify gram-positive and gram-negative bacteria (GP and GN cards, respectively) in comparison to fluorimetric cards (ID-GPC and ID-GNB, respectively). A total of 580 clinical isolates and stock collection strains belonging to 116 taxa were included in the study. Of the 249 gram-positive strains tested with both the ID-GPC and GP cards, 218 (87.5%) and 235 (94.4%) strains were correctly identified (to the genus and species level), respectively. Of the 331 gram-negative strains tested with the ID-GNB and GN cards, 295 (89.1%) and 321 (97%) strains were correctly identified, respectively. Another focus of the study was to apply the percentages of correct identifications obtained in this study to the list of bacteria isolated in our laboratory (32,739 isolates) in the year 2004. We obtained 97.9% correct identifications with the colorimetric cards and 93.9% with fluorescent cards.
引用
收藏
页码:4402 / 4406
页数:5
相关论文
共 11 条
[1]   Use of the MicroSeq 500 16S rRNA gene-based sequencing for identification of bacterial isolates that commercial automated systems failed to identify correctly [J].
Fontana, C ;
Favaro, M ;
Pelliccioni, M ;
Pistoia, ES ;
Favalli, C .
JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (02) :615-619
[2]   Performance of the new VITEK 2 GP card for identification of medically relevant gram-positive cocci in a routine clinical laboratory [J].
Funke, G ;
Funke-Kissling, P .
JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (01) :84-88
[3]   Evaluation of the new VITEK 2 card for identification of clinically relevant gram-negative rods [J].
Funke, G ;
Funke-Kissling, P .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (09) :4067-4071
[4]   Evaluation of the VITEK 2 system for rapid identification of medically relevant gram-negative rods [J].
Funke, G ;
Monnet, D ;
deBernardis, C ;
von Graevenitz, A ;
Freney, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (07) :1948-1952
[5]   Evaluation of an automated system for identification of Enterobacteriaceae and nonfermenting bacilli [J].
Jossart, MF ;
Courcol, RJ .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1999, 18 (12) :902-907
[6]   Evaluation of VITEK 2 rapid identification and susceptibility testing system against Gram-negative clinical isolates [J].
Ling, TKW ;
Tam, PC ;
Liu, ZK ;
Cheng, AFB .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (08) :2964-2966
[7]   rpoB sequence analysis as a novel basis for bacterial identification [J].
Mollet, C ;
Drancourt, M ;
Raoult, D .
MOLECULAR MICROBIOLOGY, 1997, 26 (05) :1005-1011
[8]  
O'Hara C.M., 2003, MANUAL CLIN MICROBIO, P185
[9]   Rapid and accurate species-level identification of coagulase-negative staphylococci by using the sodA gene as a target [J].
Poyart, C ;
Quesne, G ;
Boumaila, C ;
Trieu-Cuot, P .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (12) :4296-4301
[10]  
Rantakokko-Jalava K, 2000, J CLIN MICROBIOL, V38, P32