Determination of operation envelopes for closed, two-phase thermosyphons

被引:55
作者
El-Genk, MS [1 ]
Saber, HH [1 ]
机构
[1] Univ New Mexico, Dept Chem & Nucl Engn, Inst Space & Nucl Power Studies, Albuquerque, NM 87131 USA
关键词
D O I
10.1016/S0017-9310(98)00212-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
A concern in the design and operation of closed, two-phase therosyphons (CTPTs) is determining the initial filling ratio of the working fluid, as a function of CTPT dimensions, type and vapor temperature of working fluid and power throughput, to maximize performance, while avoiding potential dryout in the evaporator section. A one-dimensional, steady-stale model is developed for determining the operation envelopes of CTPTs: in terms of the above parameters. The CTPT operation envelope is basically an enclosure with three boundaries. The lower boundary corresponds to when the liquid film thickness in the evaporator reaches a critical value-beyond it the liquid film could dry out-while the upper boundary corresponds to when the expanding liquid pool, due to boiling, fills the entire evaporator. The third and closing boundary corresponds to the counter-current flooding limit (CCFL) at the exit of evaporator. The correlation developed to calculate the expanded liquid pool height in the evaporator agrees with experimental data of acetone: ethanol and water to within +/- 8%. Also, the calculated upper and lower boundaries of the operation envelope for an ammonia CTPT are in excellent agreement with experimental data [1]. Calculations showed that increasing the CTPT diameter, evaporator length, or vapor temperature expands the operation envelope, while increasing either the condenser or the adiabatic section length only slightly changes the envelope's upper and lower boundaries. (C) 1998 Elsevier Science Ltd. ALL rights reserved.
引用
收藏
页码:889 / 903
页数:15
相关论文
共 20 条
[1]  
Andros F.E., 1980, THESIS ARIZONA STATE
[2]  
Bharathan D., 1979, NP1165 EPRI
[3]   Heat transfer correlations for liquid film in the evaporator of enclosed, gravity-assisted thermosyphons [J].
El-Genk, MS ;
Saber, HH .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1998, 120 (02) :477-484
[4]   Flooding limit in closed, two-phase flow thermosyphons [J].
ElGenk, MS ;
Saber, HH .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1997, 40 (09) :2147-2164
[5]   Heat transfer correlations for small, uniformly heated liquid pools [J].
ElGenk, MS ;
Saber, HH .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1998, 41 (02) :261-274
[6]  
ELGENK MS, 1996, AICHE S SERIES, V92, P342
[7]  
ELGENK MS, 1998, P 7 AIAA ASME JOINT, P99
[8]   HEAT-TRANSFER TO FALLING LIQUID-FILMS AND FILM BREAKDOWN .1. SUBCOOLED LIQUID-FILMS [J].
FUJITA, T ;
UEDA, T .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1978, 21 (02) :97-108
[9]  
GROLMES MA, 1974, AICHE S SERIES, V38
[10]  
JIALUN H, 1992, P 8 INT HEAT PIP C B, P154