Effect of lung inhomogeneity on dose distribution during radiotherapy of patient with lung cancer

被引:0
|
作者
Zabihzadeh, M. [1 ,2 ,3 ]
Ghahremani, Z. [2 ]
Hoseini, S. M. [3 ]
Shahbazian, H. [3 ]
Ghahfarokhi, M. Hoseini [4 ]
机构
[1] Ahvaz Jundishapur Univ Med Sci, Canc Res Ctr, Ahvaz, Iran
[2] Ahvaz Jundishapur Univ Med Sci, Sch Med, Dept Med Phys, Ahvaz, Iran
[3] Ahvaz Jundishapur Univ Med Sci, Golestan Hosp, Dept Clin Oncol, Ahvaz, Iran
[4] Kermanshah Univ Med Sci, Radiol & Nucl Med, Kermanshah, Iran
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2020年 / 18卷 / 03期
关键词
Electronic disequilibrium; lung cancer radiotherapy; Monte Carlo simulation; inhomogeneity correction factor; MONTE-CARLO EVALUATION; MODULATED RADIATION-THERAPY; HETEROGENEOUS PHANTOMS; BEAM; ALGORITHMS; ACCURACY; IMRT;
D O I
10.18869/acadpub.ijrr.18.3.579
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Presence of inhomogeneities such as lung tissue with low density can perturbs the dose distribution in the path of therapeutic photon beam and causes undesired cold or hot spots. The aim of this study was to investigate the effect of lung tissue inhomogeneities on dose distribution in thorax irradiation. Materials and Methods: The Monte Carlo simulation (MC) code of EGSnrc-based BEAMnrc was used to calculate dose distribution for 6 MV- Siemens Primus linear accelerator (Linac) in a homogenous phantom. Dose perturbation and inhomogeneity corrected factors (ICFs) were calculated due to implementation of lung tissue depended to the lung density and field size. Results: The maximum increased dose in lung tissue with lung density of 0.5 and 0.25gr/cm(3) was 15.9%, 16.2%, 15.6%, 23.8 %, 24.8% and 25.0% for 6 x 6, 10 x 10 and 20 x 20 cm(2) field sizes, respectively. The maximum ICF for these field sizes was 1.16 and 1.25 for lung density of 0.5 and 0.25gr/cm(3), respectively. The maximum dose reduction in lung tissue with density of 0.25 and 0.5gr/cm(3) was 19.5% and 4.2 %, and the related ICF was estimated 0.84 and 0.95, respectively. Conclusion: Involvement of lung tissue in the path of irradiation perturbs the dose distribution which is dependent to the lung density and field size. The ICFs resulted from our MC model could be useful to accurately calculate the dose distribution in radiotherapy of lung abnormalities.
引用
收藏
页码:579 / 586
页数:8
相关论文
共 50 条
  • [31] Calculation of Organ Dose Distribution (in-field and Out-of-field) in Breast Cancer Radiotherapy on RANDO Phantom Using GEANT4 Application for Tomographic Emission (Gate) Monte Carlo Simulation
    Behmadi, Marziyeh
    Toossi, Mohammad Taghi Bahreyni
    Nasseri, Shahrokh
    Ravari, Mohammad Ehsan
    Momennezhad, Mahdi
    Gholamhosseinian, Hamid
    Mohammadi, Mohammad
    Mdletshe, Sibusiso
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2024, 14 (06):
  • [32] Recent developments in the field of radiotherapy for the management of lung cancer
    Shirai, Katsuyuki
    Aoki, Shuri
    Endo, Masashi
    Takahashi, Yuta
    Fukuda, Yukiko
    Akahane, Keiko
    Musha, Atsushi
    Sato, Harutoshi
    Wakatsuki, Masaru
    Ishikawa, Hitoshi
    Sasaki, Ryohei
    JAPANESE JOURNAL OF RADIOLOGY, 2025, 43 (02) : 186 - 199
  • [33] Respiratory Gating Techniques for Optimization of Lung Cancer Radiotherapy
    Giraud, Philippe
    Morvan, Esra
    Claude, Line
    Mornex, Francoise
    Le Pechoux, Cecile
    Bachaud, Jean-Marc
    Boisselier, Pierre
    Beckendorf, Veronique
    Morelle, Magali
    Carrere, Marie-Odile
    JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (12) : 2058 - 2068
  • [34] "Dose of the day" based on cone beam computed tomography and deformable image registration for lung cancer radiotherapy
    Yuan, Zilong
    Rong, Yi
    Benedict, Stanley H.
    Daly, Megan E.
    Qiu, Jianfeng
    Yamamoto, Tokihiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 88 - 94
  • [35] The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: Implications for tumour coverage
    Aarup, Lasse Rye
    Nahum, Alan E.
    Zacharatou, Christina
    Juhler-Nottrup, Trine
    Knoos, Tommy
    Nystrom, Hakan
    Specht, Lena
    Wieslander, Elinore
    Korreman, Stine S.
    RADIOTHERAPY AND ONCOLOGY, 2009, 91 (03) : 405 - 414
  • [36] On the dose to a moving target in stereotactic ablative body radiotherapy to lung tumors
    Feygelman, V.
    Dilling, T. J.
    Moros, E. G.
    Zhang, G. G.
    MICRO-MINI & NANO-DOSIMETRY & INNOVATIVE TECHNOLOGIES IN RADIATION THERAPY (MMND&ITRO2016), 2017, 777
  • [37] Clinical Application of a Hybrid RapidArc Radiotherapy Technique for Locally Advanced Lung Cancer
    Silva, Scott R.
    Surucu, Murat
    Steber, Jennifer
    Harkenrider, Matthew M.
    Choi, Mehee
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (02) : 224 - 230
  • [38] Classification of changes occurring in lung patient during radiotherapy using relative analysis and hidden Markov models
    Varfalvy, Nicolas
    Piron, Ophelie
    Cyr, Marc Francois
    Dagnault, Anne
    Archambault, Louis
    MEDICAL PHYSICS, 2017, 44 (10) : 5043 - 5050
  • [39] Evaluation of Dose Distribution in Intensity Modulated Radiosurgery for Lung Cancer under Condition of Respiratory Motion
    Yoon, Mee Sun
    Jeong, Jae-Uk
    Nam, Taek-Keun
    Ahn, Sung-Ja
    Chung, Woong-Ki
    Song, Ju-Young
    PLOS ONE, 2016, 11 (09):
  • [40] A modified formula for dose calculations of stereotactic ablative body radiotherapy for non-small cell lung cancer
    Cao, Yangsen
    Zhu, Xiaofei
    Zhang, Yu
    Yu, Chunshan
    Liu, Yongming
    Sun, Yongjian
    Dai, Zhitao
    Guo, Xueling
    Ju, Xiaoping
    Zhang, Huojun
    MEDICAL DOSIMETRY, 2018, 43 (03) : 207 - 213