Phase-contrast imaging for body composition measurement

被引:3
作者
Han, Huajie [1 ,2 ]
Hu, Renfang [2 ]
Wali, Faiz [2 ]
Wu, Zhao [2 ]
Gao, Kun [2 ]
Wang, Shenghao [3 ]
Gu, Yonggang [4 ]
Jin, Yi [4 ]
Zhai, Chao [4 ]
机构
[1] Univ Sci & Technol China, Dept Precis Machinery & Precis Instrumentat, Hefei 230027, Anhui, Peoples R China
[2] Univ Sci & Technol China, Natl Synchrotron Radiat Lab, Hefei 230027, Anhui, Peoples R China
[3] Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Shanghai 201800, Peoples R China
[4] Univ Sci & Technol China, Expt Ctr Engn & Mat Sci, Hefei 230027, Anhui, Peoples R China
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2017年 / 43卷
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
X-ray phase-contrast imaging; Body composition measurement; X-RAY RADIOGRAPHY; GRATING INTERFEROMETRY; COMPUTED-TOMOGRAPHY; RETRIEVAL; ABSORPTION;
D O I
10.1016/j.ejmp.2017.10.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In this paper, we propose a novel method for human body composition measurement, especially for the bone mineral density (BMD) measurement. The proposed method, using the absorption and differential phase information retrieved from X-ray grating-based interferometer (XGBI) to measure the BMD, has potential to replace dual-energy X-ray absorptiometry (DEXA), which is currently widely used for body composition measurement. Methods: The DEXA method employs two absorption images acquired at two different X-ray spectra (high energy and low energy) to calculate the human body composition. In this paper, a new method to calculate BMD using a single X-ray measurement is proposed. XGBI is a relatively new X-ray technique that provides absorption, phase and scattering information simultaneously using a single X-ray spectrum. With the absorption and differential phase information retrieved from XGBI, BMD can be measured using only one single X-ray spectrum. Numerical simulations are performed with a body phantom of bone (Cortical, ICRU-44) surrounded by soft tissue (Soft, ICRU-44). BMD is calculated with both the DEXA method and the proposed method. Results: Results show that BMD can be measured accurately with the proposed method; moreover, better signal-to-noise ratio (SNR) is obtained compared to DEXA. Conclusion: With the proposed method, BMD can be measured with XGBI setup. Further, the proposed method can be realized using current X-ray phase-contrast imaging (XPCI) apparatus without any hardware modification, suggesting that this technique can be a promising supplementary function to current XPCI equipment.
引用
收藏
页码:25 / 33
页数:9
相关论文
共 31 条
[1]   Current Status of Body Composition Assessment in Sport Review and Position Statement on Behalf of the Ad Hoc Research Working Group on Body Composition Health and Performance, Under the Auspices of the I.O.C. Medical Commission [J].
Ackland, Timothy R. ;
Lohman, Timothy G. ;
Sundgot-Borgen, Jorunn ;
Maughan, Ronald J. ;
Meyer, Nanna L. ;
Stewart, Arthur D. ;
Mueller, Wolfram .
SPORTS MEDICINE, 2012, 42 (03) :227-249
[2]  
Bartlomiej Wlodarczyk, 2017, PHYS MED
[3]   AN ACCURATE METHOD FOR DIRECT DUAL-ENERGY CALIBRATION AND DECOMPOSITION [J].
CARDINAL, HN ;
FENSTER, A .
MEDICAL PHYSICS, 1990, 17 (03) :327-341
[4]   Beam hardening effects in grating-based x-ray phase-contrast imaging [J].
Chabior, Michael ;
Donath, Tilman ;
David, Christian ;
Bunk, Oliver ;
Schuster, Manfred ;
Schroer, Christian ;
Pfeiffer, Franz .
MEDICAL PHYSICS, 2011, 38 (03) :1189-1195
[5]   A single-image retrieval method for edge illumination X-ray phase-contrast imaging: Application and noise analysis [J].
Diemoz, Paul C. ;
Vittoria, Fabio A. ;
Hagen, Charlotte K. ;
Endrizzi, Marco ;
Coan, Paola ;
Bravin, Alberto ;
Wagner, Ulrich H. ;
Rau, Christoph ;
Robinson, Ian K. ;
Olivo, Alessandro .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12) :1759-1764
[6]   Noise analysis of grating-based x-ray differential phase-contrast imaging with angular signal radiography [J].
Faiz, Wali ;
Bao, Yuan ;
Gao, Kun ;
Wu, Zhao ;
Wei, Chen-Xi ;
Zan, Gui-Bin ;
Zhu, Pei-Ping ;
Tian, Yang-Chao .
CHINESE PHYSICS B, 2017, 26 (04)
[7]  
Glen M Blake, 1997, SEM NUCL MED, V27
[8]   Preliminary research on dual-energy X-ray phase-contrast imaging [J].
Han, Hua-Jie ;
Wang, Sheng-Hao ;
Gao, Kun ;
Wang, Zhi-Li ;
Zhang, Can ;
Yang, Meng ;
Zhang, Kai ;
Zhu, Pei-Ping .
CHINESE PHYSICS C, 2016, 40 (04)
[9]   Effective x-ray attenuation measurements with full field digital mammography [J].
Heine, John J. ;
Behera, Madhusmita .
MEDICAL PHYSICS, 2006, 33 (11) :4350-4366
[10]   High-energy x-ray Talbot-Lau radiography of a human knee [J].
Horn, F. ;
Gelse, K. ;
Jabari, S. ;
Hauke, C. ;
Kaeppler, S. ;
Ludwig, V. ;
Meyer, P. ;
Michel, T. ;
Mohr, J. ;
Pelzer, G. ;
Rieger, J. ;
Riess, C. ;
Seifert, M. ;
Anton, G. .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (16) :6729-6745