Dynamic visualization of lung sounds with a vibration response device: A case series

被引:68
作者
Dellinger, R. Phillip [2 ]
Parrillo, Joseph E. [2 ]
Kushnir, Alon [1 ]
Rossi, Marcello [3 ]
Kushnir, Igal [1 ]
机构
[1] Deep Breeze Ltd, IL-30600 Or Akiva, Israel
[2] Univ Med & Dent New Jersey, Robert Wood Johnson Med Sch, Cooper Univ Hosp, Div Cardiovasc Dis & Crit Care Med, Camden, NJ 08103 USA
[3] Azienda Osped Univ Senese, Fisiopatol & Riabilitaz Resp, Siena, Italy
关键词
acoustic mapping; acoustic imaging; lung ventilation; pulmonary imaging; respiratory sounds;
D O I
10.1159/000103558
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: The field of computer-assisted mapping of lung sounds is constantly evolving and several devices have been developed in this field. Objectives: Our objective was to evaluate a new computer-assisted lung sound imaging system, 'vibration response imaging' (VRI), that records and creates a dynamic image of breath sounds. We postulated that the VRI display format would qualitatively and quantitatively reveal breath sound distribution throughout the breathing cycle. Methods: Lung sounds were recorded from 5 healthy adults and 14 patients with various respiratory illnesses using VRI. The lung sounds were processed by the VRI software, which incorporates an algorithm to convert breath sounds in the frequency range of 150 - 250 Hz to a dynamic image and quantitative assessment of breath sound distribution. Results: Images and quantifications from recordings of the healthy adults showed distinct patterns for inspiration and expiration. Images and quantifications from the subjects with respiratory illness differed substantially from the images of the healthy subjects. Both healthy and pathological subjects presented some expected characteristics of breath sound distribution. Conclusions: The VRI device may provide a new perspective in acoustic imaging and quantification of breath sounds by adding aspects of time analysis and quantification of distribution to existing methods. Further studies will be required in order to establish reliability of repeated recordings and to validate the sensitivity of the system in detecting various lung pathologies. Copyright (C) 2007 S. Karger AG, Basel.
引用
收藏
页码:60 / 72
页数:13
相关论文
共 27 条
[1]   VARIATION OF BREATH SOUND AND AIRWAY CALIBER INDUCED BY HISTAMINE CHALLENGE [J].
ANDERSON, K ;
AITKEN, S ;
CARTER, R ;
MACLEOD, JES ;
MORAN, F .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1990, 141 (05) :1147-1150
[2]  
[Anonymous], 2000, Eur Respir Rev
[3]   Thoracic dimensions at maximum lung inflation in normal subjects and in patients with obstructive and restrictive lung diseases [J].
Bellemare, JF ;
Cordeau, MP ;
Leblanc, P ;
Bellemare, F .
CHEST, 2001, 119 (02) :376-386
[4]  
BOHADANA AB, 1994, RESPIRATION, V61, P274
[5]   Respiratory acoustic thoracic imaging (RATI):: assessing deterministic interpolation techniques [J].
Charleston-Villalobos, S ;
Cortés-Rubiano, S ;
González-Camarena, R ;
Chi-Lem, G ;
Alijama-Corrales, T .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2004, 42 (05) :618-626
[6]   LUNG SOUND INTENSITY VARIABILITY IN NORMAL MEN - A CONTOUR PHONOPNEUMOGRAPHIC STUDY [J].
DOSANI, R ;
KRAMAN, SS .
CHEST, 1983, 83 (04) :628-631
[7]  
Earis JE., 2000, EUR RESPIR REV, V10, P641
[8]   Validity and reliability of acoustic analysis of respiratory sounds in infants [J].
Elphick, HE ;
Lancaster, GA ;
Solis, A ;
Majumdar, A ;
Gupta, R ;
Smyth, RL .
ARCHIVES OF DISEASE IN CHILDHOOD, 2004, 89 (11) :1059-1063
[9]   Analysis of forced wheezes in asthma patients [J].
Fiz, JA ;
Jané, R ;
Izquierdo, J ;
Homs, A ;
García, MA ;
Gomez, R ;
Monso, E ;
Morera, J .
RESPIRATION, 2006, 73 (01) :55-60
[10]   Acoustic imaging of the human chest [J].
Kompis, M ;
Pasterkamp, H ;
Wodicka, GR .
CHEST, 2001, 120 (04) :1309-1321