A wavelet-PCA method saves high mass resolution information in data treatment of SIMS molecular depth profiles

被引:9
作者
Tuccitto, Nunzio [1 ]
Zappala, Gabriella
Vitale, Stefania
Torrisi, Alberto
Licciardello, Antonino
机构
[1] Univ Catania, Dept Chem Sci, Viale A Doria 6, I-95125 Catania, Italy
关键词
wavelet transform; ToF-SIMS; molecular depth profiling; principal component analysis; polyelectrolytes; TOF-SIMS; POLYELECTROLYTE MULTILAYER; THIN-FILMS; SPECTROMETRY; MULTIVARIATE; IMAGES; POLYMERS; FABRICATION; ENERGY;
D O I
10.1002/sia.5943
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A detailed depth characterization of multilayered polymeric systems is a very attractive topic. Currently, the use of cluster primary ion beams in time-of-flight secondary ion mass spectrometry allows molecular depth profiling of organic and polymeric materials. Because typical raw data may contain thousands of peaks, the amount of information to manage grows rapidly and widely, so that data reduction techniques become indispensable in order to extract the most significant information from the given dataset. Here, we show how the wavelet-based signal processing technique can be applied to the compression of the giant raw data acquired during time-of-flight secondary ion mass spectrometry molecular depth-profiling experiments. We tested the approach on data acquired by analyzing a model sample consisting of polyelectrolyte-based multilayers spin-cast on silicon. Numerous wavelet mother functions and several compression levels were investigated. We propose some estimators of the filtering quality in order to find the highest 'safe' approximation value in terms of peaks area modification, signal to noise ratio, and mass resolution retention. The compression procedure allowed to obtain a dataset straightforwardly 'manageable' without any peak-picking procedure or detailed peak integration. Moreover, we show that multivariate analysis, namely, principal component analysis, can be successfully combined to the results of the wavelet-filtering, providing a simple and reliable method for extracting the relevant information from raw datasets. Copyright (C) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:317 / 327
页数:11
相关论文
共 40 条
[1]  
[Anonymous], 2009, WAVELET TOUR SIGNAL
[2]   3D ToF-SIMS Imaging of Polymer Multi layer Films Using Argon Cluster Sputter Depth Profiling [J].
Bailey, James ;
Havelund, Rasmus ;
Shard, Alexander G. ;
Gilmore, Ian S. ;
Alexander, Morgan R. ;
Sharp, James S. ;
Scurr, David J. .
ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (04) :2654-2659
[3]   CHEMICAL-ANALYSIS OF INORGANIC AND ORGANIC-SURFACES AND THIN-FILMS BY STATIC TIME-OF-FLIGHT SECONDARY-ION MASS-SPECTROMETRY (TOF-SIMS) [J].
BENNINGHOVEN, A .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1994, 33 (10) :1023-1043
[4]   Principal component analysis [J].
Bro, Rasmus ;
Smilde, Age K. .
ANALYTICAL METHODS, 2014, 6 (09) :2812-2831
[5]  
Chiarelli PA, 2001, ADV MATER, V13, P1167, DOI 10.1002/1521-4095(200108)13:15<1167::AID-ADMA1167>3.0.CO
[6]  
2-A
[7]  
Cho J, 2001, ADV MATER, V13, P1076, DOI 10.1002/1521-4095(200107)13:14<1076::AID-ADMA1076>3.0.CO
[8]  
2-M
[9]   Multivariate analysis of extremely large ToFSIMS imaging datasets by a rapid PCA method [J].
Cumpson, Peter J. ;
Sano, Naoko ;
Fletcher, Ian W. ;
Portoles, Jose F. ;
Bravo-Sanchez, Mariela ;
Barlow, Anders J. .
SURFACE AND INTERFACE ANALYSIS, 2015, 47 (10) :986-993
[10]   Multivariate Analysis of ToF-SIMS Data from Multicomponent Systems: The Why, When, and How [J].
Graham, Daniel J. ;
Castner, David G. .
BIOINTERPHASES, 2012, 7 (1-4) :1-12