New closed-form expressions for the estimation of arterial windkessel compliance

被引:10
|
作者
Gnudi, G [1 ]
机构
[1] Univ Bologna, DEIS, Dept Elect Informat & Syst, I-40136 Bologna, Italy
关键词
arterial system; mathematical models; windkessel model; arterial compliance; parameter estimation; energy balance;
D O I
10.1016/S0010-4825(98)00008-0
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
New closed-form mathematical expressions, in the time- and frequency-domain, are derived for estimating the arterial windkessel compliance. The proposed expressions assume the three-element windkessel to model the arterial system and require the measurements of the entire waveforms of arterial pressure and flow. The resistance parameters are estimated using the recently proposed energy-balance method, then compliance is analytically calculated in order to minimize the pressure error in the compliant element. The derived expressions remain valid even when the windkessel compliance is assumed to be pressure-dependent. Also, it is shown that the method, either time- or frequency-domain formulation, provides parameter estimates, which minimize the arterial pressure square error. The method has been applied to simulated data as well as to pressure and flow data measured in the ascending aorta of three anaesthetized dogs under different circulatory conditions. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:207 / 223
页数:17
相关论文
共 50 条
  • [41] A Closed-Form, Pairwise Solution to Local Non-Rigid Structure-From-Motion
    Parashar, Shaifali
    Long, Yuxuan
    Salzmann, Mathieu
    Fua, Pascal
    IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2024, 46 (11) : 7027 - 7040
  • [42] AN IMPROVEMENT OF THE RECURSIVE CLOSED-FORM ALGORITHM FOR NON-MINIMUM PHASE FIR SYSTEM IDENTIFICATION
    梁应敞
    王树勋
    戴逸松
    JournalofElectronics(China), 1993, (02) : 188 - 192
  • [43] Shear strength of squat walls: A strut-and-tie model and closed-form design formula
    Kassem, Wael
    ENGINEERING STRUCTURES, 2015, 84 : 430 - 438
  • [44] Closed-form, robust and accurate multi-frequency phase unwrapping: Frequency design and algorithm
    Wei, Li
    Qi, Wangdong
    Xu, Youyun
    Xu, Bing
    SIGNAL PROCESSING, 2017, 138 : 159 - 166
  • [45] Different Methods of Arterial Compliance Estimation Tested with Reservoir-Wave Model of Arterial System
    Zylinski, Marek
    Niewiadomski, Wiktor
    Sadowiec, Marta
    Cybulski, Gerard
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 707 - 710
  • [46] A Closed-Form Approximation for Sunde's Ground-Return Expression Based on a Pade Approximant
    De Conti, Alberto
    de Lima, Antonio Carlos Siqueira
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2024, 66 (03) : 993 - 1000
  • [47] Robust arterial compliance estimation with Katz's fractal dimension of photoplethysmography
    Xing, Xiaoman
    Hong, Jingyuan
    Alastruey, Jordi
    Long, Xi
    Liu, Haipeng
    Dong, Wen-Fei
    FRONTIERS IN PHYSIOLOGY, 2024, 15
  • [48] A realistic closed-form radiobiological model of clinical tumor-control data incorporating intertumor heterogeneity
    Roberts, SA
    Hendry, JH
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (03): : 689 - 699
  • [49] Closed-Form Two-Way TOA Localization and Synchronization for User Devices With Motion and Clock Drift
    Zhao, Sihao
    Guo, Ningyan
    Zhang, Xiao-Ping
    Cui, Xiaowei
    Lu, Mingquan
    IEEE SIGNAL PROCESSING LETTERS, 2022, 29 : 100 - 104
  • [50] Hand-Eye Calibration Made Easy Through a Closed-Form Two-Stage Method
    Sarabandi, Soheil
    Porta, Josep M.
    Thomas, Federico
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2022, 7 (02) : 3679 - 3686