New closed-form expressions for the estimation of arterial windkessel compliance

被引:10
|
作者
Gnudi, G [1 ]
机构
[1] Univ Bologna, DEIS, Dept Elect Informat & Syst, I-40136 Bologna, Italy
关键词
arterial system; mathematical models; windkessel model; arterial compliance; parameter estimation; energy balance;
D O I
10.1016/S0010-4825(98)00008-0
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
New closed-form mathematical expressions, in the time- and frequency-domain, are derived for estimating the arterial windkessel compliance. The proposed expressions assume the three-element windkessel to model the arterial system and require the measurements of the entire waveforms of arterial pressure and flow. The resistance parameters are estimated using the recently proposed energy-balance method, then compliance is analytically calculated in order to minimize the pressure error in the compliant element. The derived expressions remain valid even when the windkessel compliance is assumed to be pressure-dependent. Also, it is shown that the method, either time- or frequency-domain formulation, provides parameter estimates, which minimize the arterial pressure square error. The method has been applied to simulated data as well as to pressure and flow data measured in the ascending aorta of three anaesthetized dogs under different circulatory conditions. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:207 / 223
页数:17
相关论文
共 50 条
  • [1] Closed-form Bias Reduction for Shape Estimation with Polygon Models
    Faion, Florian
    Dolgov, Maxim
    Zea, Antonio
    Hanebeck, Uwe D.
    2016 19TH INTERNATIONAL CONFERENCE ON INFORMATION FUSION (FUSION), 2016, : 581 - 588
  • [2] Comparison of segmental arterial compliance determined with three and four element Windkessel models
    Ferreira, AS
    Barbosa, J
    Souza, MN
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3161 - 3164
  • [3] Closed-form estimator for widening valid estimation range of Pareto parameter
    Hu C.
    Luo F.
    Zhang L.
    Chen S.
    Fan Y.
    Xi'an Dianzi Keji Daxue Xuebao, 2 (33-36 and 113): : 33 - 36and113
  • [4] ARTERIAL WINDKESSEL PARAMETER-ESTIMATION - A NEW TIME-DOMAIN METHOD
    SHIM, YT
    PASIPOULARIDES, A
    STRALEY, CA
    HAMPTON, TG
    SOTO, PF
    OWEN, CH
    DAVIS, JW
    GLOWER, DD
    ANNALS OF BIOMEDICAL ENGINEERING, 1994, 22 (01) : 66 - 77
  • [5] Towards accurate calculation of supercapacitor electrical variables in constant power applications using new analytical closed-form expressions
    Calasan, Martin
    Zobaa, Ahmed F.
    Hasanien, Hany M.
    Aleem, Shady H. E. Abdel
    Ali, Ziad M.
    JOURNAL OF ENERGY STORAGE, 2021, 42
  • [6] Noninvasive Arterial Compliance Estimation
    Svec, David
    Javorka, Michal
    PHYSIOLOGICAL RESEARCH, 2021, 70 : S483 - S494
  • [7] Closed-Form Expressions for the Input Impedance of Some 2-D Fractal Circuit Networks
    Elwakil, Ahmed S.
    Allagui, Anis
    Elamien, Mohamed B.
    Psychalinos, Costas
    Maundy, Brent
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2025, 72 (01) : 18 - 22
  • [8] Closed-Form Expressions for InSAR Sample Statistics and Its Application to Non-Gaussian Data
    Gierull, Christoph H.
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2021, 59 (05): : 3967 - 3980
  • [9] Contrast estimation for noisy observations of diffusion processes via closed-form density expansions
    El Kolei, Salima
    Navarro, Fabien
    STATISTICAL INFERENCE FOR STOCHASTIC PROCESSES, 2022, 25 (02) : 303 - 336
  • [10] A CLOSED-FORM SOLUTION FOR MULTILINEAR PARAFAC DECOMPOSITIONS
    Roemer, Florian
    Haardt, Martin
    2008 IEEE SENSOR ARRAY AND MULTICHANNEL SIGNAL PROCESSING WORKSHOP, 2008, : 488 - 492