Diagnostic value of SPECT versus SPECT/CT in femoral avascular necrosis: preliminary results
被引:20
作者:
Luk, Wing Hang
论文数: 0引用数: 0
h-index: 0
机构:
United Christian Hosp, Dept Diagnost Radiol & Organ Imaging, Kowloon, Hong Kong, Peoples R ChinaUnited Christian Hosp, Dept Diagnost Radiol & Organ Imaging, Kowloon, Hong Kong, Peoples R China
Luk, Wing Hang
[1
]
Au-Yeung, Andrea Wai San
论文数: 0引用数: 0
h-index: 0
机构:
United Christian Hosp, Dept Diagnost Radiol & Organ Imaging, Kowloon, Hong Kong, Peoples R ChinaUnited Christian Hosp, Dept Diagnost Radiol & Organ Imaging, Kowloon, Hong Kong, Peoples R China
Au-Yeung, Andrea Wai San
[1
]
Yang, Michael Kwok Wai
论文数: 0引用数: 0
h-index: 0
机构:
United Christian Hosp, Dept Diagnost Radiol & Organ Imaging, Kowloon, Hong Kong, Peoples R ChinaUnited Christian Hosp, Dept Diagnost Radiol & Organ Imaging, Kowloon, Hong Kong, Peoples R China
Yang, Michael Kwok Wai
[1
]
机构:
[1] United Christian Hosp, Dept Diagnost Radiol & Organ Imaging, Kowloon, Hong Kong, Peoples R China
bone scintigraphy;
hip avascular necrosis;
radionuclide;
SPECT/CT;
HEAD;
HIP;
CT;
MR;
OSTEONECROSIS;
SCINTIGRAPHY;
D O I:
10.1097/MNM.0b013e32833e7732
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Objective With the advent of single-photon emission computer tomography/computed tomography (SPECT/CT), its applications and indications have to be evaluated clinically for a more efficient and cost-effective use in patient management. This retrospective study investigated the clinical value of conventional (99m)Tc MDP SPECT against SPECT/CT in diagnosing hip avascular necrosis (AVN). Methods This retrospective study evaluated all patients who underwent SPECT/CT during the period from 1 March 2008 to 31 July 2009 for possible femoral AVN for which MRI was contraindicated. The SPECT and SPECT/CT images were reviewed separately by two radiologists with different levels of experience in a double-blinded manner. The likelihood of AVN for each symptomatic hip was graded according to the level of confidence. Clinical outcome was considered as the gold standard. The sensitivity, specificity, and accuracy for SPECT and SPECT/CT by each radiologist was obtained and compared with the gold standard. The corresponding receiver operating characteristic (ROC) curve and area under the curve (AUC) were used to evaluate the diagnostic power of SPECT against SPECT/CT. Results A total of 22 patients and 24 symptomatic hips were analyzed. Seven hips (29%) were confirmed to have AVN. The AUCs obtained from ROC for trainee radiologist for SPECT vs. SPECT/CT were 0.828 and 0.916, respectively. The AUC for specialist radiologist increased from 0.916 to 0.941 with CT. Conclusion We concluded that SPECT/CT is beneficial for the improvement of AUC in ROC on the diagnostic of hip AVN compared with SPECT alone. Nucl Med Commun 31: 958-961 (C) 2010 Wolters Kluwer Health | Lippincott Williams & Wilkins.