Reactive Power Capability of Wind Turbines Based on Doubly Fed Induction Generators

被引:173
|
作者
Engelhardt, Stephan [1 ]
Erlich, Istvan [2 ]
Feltes, Christian [2 ]
Kretschmann, Joerg [1 ]
Shewarega, Fekadu [2 ]
机构
[1] Woodward SEG GmbH & Co KG, D-47906 Kempen, Germany
[2] Univ Duisburg Essen, D-47057 Duisburg, Germany
关键词
Doubly fed induction generator (DFIG); power conversion; reactive power; voltage support; wind power; wind turbine;
D O I
10.1109/TEC.2010.2081365
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the increasing penetration of wind turbines (WTs) grid utilities require extended reactive power supply capability not only during voltage dips but also in steady-state operation. WTs with doubly fed induction generators (DFIG) are able to control active and reactive power independently. The reactive power capability is subject to several limitations resulting from the voltage, current, and speed, which change with the operating point. This paper discusses the steady-state reactive power loading capability of DFIG-based WTs by taking into account the most important physical phenomena restricting the reactive power supply of DFIG-based WT systems. The active-reactive power diagram is systematically derived by considering the typical power-speed relationship and converter loading limits. The authors discuss also some special operating modes limiting the reactive power capability together with aspects of modeling and control that give rise to these limitations.
引用
收藏
页码:364 / 372
页数:9
相关论文
共 50 条
  • [21] Power Estimation of Induction Generators fed from Wind Turbines
    Mipoung, O. D.
    Lopes, L. A. C.
    Pillay, P.
    2011 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2011,
  • [22] Flicker study on variable speed wind turbines with doubly fed induction generators
    Sun, T
    Chen, Z
    Blaabjerg, F
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (04) : 896 - 905
  • [23] Comparison of stabilizing methods for doubly-fed induction generators for wind turbines
    La Seta, Piergiovanni
    Schegner, Peter
    2005 International Conference on Future Power Systems (FPS), 2005, : 468 - 473
  • [24] Dynamic Modeling and Control of Doubly Fed Induction Generators Driven by Wind Turbines
    Qiao, Wei
    2009 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION, VOLS 1-3, 2009, : 363 - 370
  • [25] A new monitoring system for wind turbines with doubly-fed induction generators
    Yazidi, A.
    Capolino, G. A.
    Filippetti, F.
    Casadei, D.
    CIRCUITS AND SYSTEMS FOR SIGNAL PROCESSING , INFORMATION AND COMMUNICATION TECHNOLOGIES, AND POWER SOURCES AND SYSTEMS, VOL 1 AND 2, PROCEEDINGS, 2006, : 1142 - 1145
  • [26] Fuzzy Logic-Enhanced Direct Power Control for Wind Turbines with Doubly Fed Induction Generators
    Sayeh, Karim Fathi
    Tamalouzt, Salah
    Ziane, Djamel
    Deffaf, Brahim
    Belaid, Sofia Lalouni
    Belkhier, Youcef
    Bajaj, Mohit
    Blazek, Vojtech
    RESULTS IN ENGINEERING, 2024, 24
  • [27] Effects of Wind Turbines Equipped with Doubly-fed Induction Generators on Distance Protection
    Hossein Kazemi KAREGAR
    Maryam KHODDAM
    电力系统自动化, 2012, 36 (08) : 128 - 131
  • [28] H∞ robust control for wind power systems based on doubly fed induction generators
    Fan, Pu-Cheng
    Wang, Chang-Song
    Wang, Zhi-Yu
    Yang, Jian-Cheng
    Beijing Keji Daxue Xuebao/Journal of University of Science and Technology Beijing, 2011, 33 (08): : 1018 - 1023
  • [29] Selection of gearbox ratio and power converters ratings for wind turbines equipped with Doubly-Fed Induction Generators
    Aguglia, Davide
    Wamkeue, Rene
    Cros, Jerome
    IEEE IEMDC 2007: PROCEEDINGS OF THE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, VOLS 1 AND 2, 2007, : 447 - +
  • [30] Impact of Wind Turbines Equipped with Doubly-Fed Induction Generators on Distance Relaying
    De Rijcke, S.
    Peerez, P. S.
    Driesen, J.
    IEEE PES GENERAL MEETING, 2010,