Cerebral metabolic rate of glucose quantification with the aortic image-derived input function and Patlak method: numerical and patient data evaluation

被引:6
|
作者
Vanzi, Eleonora [1 ]
Berti, Valentina [2 ]
Polito, Cristina [2 ]
Freddi, Ilaria [2 ]
Comis, Giannetto [2 ]
Rubello, Domenico [3 ]
Sorbi, Sandro [4 ]
Pupi, Alberto [2 ]
机构
[1] Univ Hosp Siena, Dept Med Phys, Viale Bracci 16, I-53100 Siena, Italy
[2] Univ Florence, Dept Biomed Expt & Clin Sci, Nucl Med Unit, Florence, Italy
[3] Santa Maria della Misericordia Hosp, Dept Nucl Med, Rovigo, Italy
[4] Univ Florence, Dept Psychiat & Neurol Sci, Florence, Italy
关键词
cerebral metabolic rate of glucose; image-derived input function; quantitative; 18F-FDG-PET; POSITRON-EMISSION-TOMOGRAPHY; FDG-PET; NONINVASIVE QUANTIFICATION; F-18-FDG PET; CONSTANTS; HUMANS; FLUORODEOXYGLUCOSE; QUANTITATION; BLOOD;
D O I
10.1097/MNM.0000000000000512
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeQuantitative maps of cerebral metabolic rate of glucose (CMRGlu) from fluorine-18 fluorodeoxyglucose-PET are useful in brain studies, but are challenging to acquire because of technical constraints, which hinder their use in clinical routine. Aortic image-derived input functions (IDIFs) combined with Sokoloff's method were proposed as a suitable solution. However, Sokoloff's method requires the use of standard kinetic constants, which may produce biased estimates. Patlak's method would be more appropriate, but concern can arise when used with an aortic IDIF from unavailability of a complete brain curve acquired starting from injection. The aim of this study was to develop a CMRGlu quantification technique that combines Patlak's method with aortic IDIFs in a clinical setting.Materials and methodsA simple acquisition protocol for aortic IDIF measurement was developed and applied on a sample of patients with different degrees of hypometabolism (one healthy control, four patients with a neurodegenerative condition, and one coma patient). CMRGlu estimates in vivo were obtained with both the Sokoloff method and the Patlak method. Computer simulations were performed to assess the causes of bias affecting Sokoloff and Patlak estimates and interpret the results obtained in patients.ResultsSimulations showed that Sokoloff's method is less stable than Patlak's method as the extent of bias changed across different physiological states, potentially leading to misinterpretation of clinical data. In clinical patients, Sokoloff and Patlak estimates were correlated on the whole, but deviations emerged for critical physiological states.ConclusionCMRGlu quantification with the Patlak method and aortic IDIF is feasible, easy to implement in clinical practice, and superior to Sokoloff's method from a personalized medicine perspective.
引用
收藏
页码:849 / 859
页数:11
相关论文
共 49 条
  • [1] Quantification of cerebral metabolic rate of oxygen with image-derived arterial input function
    Su, Yi
    Vlassenko, Andrei
    Derdeyn, Colin
    Benzinger, Tammie
    Raichle, Marcus
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [2] Quantification of cerebral metabolic rate of oxygen with image-derived arterial input function
    Su, Yi
    Vlassenko, Andrei
    Derdeyn, Colin
    Benzinger, Tammie
    Raichle, Marcus
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [3] Noninvasive quantification of the cerebral metabolic rate for glucose using positron emission tomography, 18F-fluoro-2-deoxyglucose, the Patlak method, and an image-derived input function
    Chen, K
    Bandy, D
    Reiman, E
    Huang, SC
    Lawson, M
    Feng, D
    Yun, LS
    Palant, A
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1998, 18 (07): : 716 - 723
  • [4] Sokoloff and Patlak methods for CMRGlu quantification with aortic image-derived input function: a feasibility study
    Vanzi, Eleonora
    Berti, Valentina
    Freddi, Ilaria
    Polito, Cristina
    Comis, Giannetto
    Pupi, Alberto
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3081 - 3083
  • [5] Impact of Image-Derived Input Function and Fit Time Intervals on Patlak Quantification of Myocardial Glucose Uptake in Mice
    Thackeray, James T.
    Bankstahl, Jens P.
    Bengel, Frank M.
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (10) : 1615 - 1621
  • [6] Non-invasive quantification of cerebral glucose metabolism using Gjedde-Patlak plot and image-derived input function from the aorta
    Henriksen, Alexander Cuculiza
    Lonsdale, Markus Nowak
    Fuglo, Dan
    Kondziella, Daniel
    Nersesjan, Vardan
    Marner, Lisbeth
    NEUROIMAGE, 2022, 253
  • [7] The use of the image-derived input function for non-invasive quantification of cerebral glucose metabolic rate in brain FDG-PET studies.
    Chen, K
    Bandy, D
    Reiman, E
    Huang, H
    Lawson, M
    Feng, D
    Yun, L
    Palant, A
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 347 - 347
  • [8] Image Quantification for TSPO PET with a Novel Image-Derived Input Function Method
    Fang, Yu-Hua Dean
    McConathy, Jonathan E.
    Yacoubian, Talene A.
    Zhang, Yue
    Kennedy, Richard E.
    Standaert, David G.
    DIAGNOSTICS, 2022, 12 (05)
  • [9] Image-Derived Input Function for Brain PET Quantification
    Gorgulho, Andre
    Caramelo, Francisco
    Patricio, Miguel
    2015 IEEE 4TH PORTUGUESE MEETING ON BIOENGINEERING (ENBENG), 2015,
  • [10] Noninvasive quantification of the cerebral metabolic rate of 18F-FDG in dynamic brain PET studies using an image-derived input function.
    Zanotti-Fregonara, P.
    Maroy, R.
    Sureau, F.
    Comtat, C.
    Jan, S.
    Syrota, A.
    Trebossen, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S144 - S144