Determination of glutamine and serine in rat cerebrospinal fluid using capillary electrochromatography with a modified photopolymerized sol-gel monolithic column

被引:26
作者
Kato, M
Jin, HM
Sakai-Kato, K
Toyo'oka, T
Dulay, MT
Zare, RN
机构
[1] Univ Shizuoka, Sch Pharmaceut Sci, Dept Analyt Chem, Shizuoka 4228526, Japan
[2] Stanford Univ, Dept Chem, Stanford, CA 94305 USA
关键词
monolithic columns; sol-gel; glutamine; serine; amino acids;
D O I
10.1016/S0021-9673(03)00451-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capillary electrochromatographic separations of amino acid mixtures were studied using two modified porous photopolymerized sol-gel monolithic columns. One was modified with dimethyloctadecylchlorosilane (DMOS), and the other was modified with DMOS, followed by chlorotrimethylsilane to end-cap residual silanol groups. Prior to separation, amino acids were derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole using as a mobile phase 50 mM phosphate (pH 2.5), water, and acetonitrile in the ratio of 1:1:8. Five derivatized amino acids (Asn, Phe, Ala, Ile, and Leu) were separated within 7 min. Theoretical plate numbers varied between 58 700 and 105 000/m. This separation method with the end-capped monolithic column was applied to rat cerebrospinal fluid. The dominant amino acid found was Gln at a concentration of 420 muM along with small quantities of Ser (54 muM). (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:209 / 215
页数:7
相关论文
共 43 条
[1]   RAPID HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE ASSAY OF GLUTAMINE IN HUMAN CEREBROSPINAL-FLUID [J].
ALFREDSSON, G ;
SEDVALL, G .
JOURNAL OF CHROMATOGRAPHY, 1983, 274 (MAY) :325-330
[2]   SIMPLE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF FREE PRIMARY AMINO-ACID-CONCENTRATIONS IN RAT PLASMA AND CISTERNAL CEREBROSPINAL-FLUID [J].
BEGLEY, DJ ;
REICHEL, A ;
ERMISCH, A .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 657 (01) :185-191
[3]   EVALUATION OF THE PARAMETERS DETERMINING THE PERFORMANCE OF ELECTROCHROMATOGRAPHY IN PACKED CAPILLARY COLUMNS [J].
BEHNKE, B ;
GROM, E ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) :207-213
[4]  
Behnke B, 2000, ELECTROPHORESIS, V21, P3102, DOI 10.1002/1522-2683(20000901)21:15<3102::AID-ELPS3102>3.0.CO
[5]  
2-V
[6]   Capillary electrochromatography [J].
Colon, LA ;
Guo, Y ;
Fermier, A .
ANALYTICAL CHEMISTRY, 1997, 69 (15) :A461-A467
[7]  
Dulay MT, 2002, J SEP SCI, V25, P3, DOI 10.1002/1615-9314(20020101)25:1/2<3::AID-JSSC3>3.0.CO
[8]  
2-L
[9]   Photopolymerized sol-gel monoliths for capillary electrochromatography [J].
Dulay, MT ;
Quirino, JP ;
Bennett, BD ;
Kato, M ;
Zare, RN .
ANALYTICAL CHEMISTRY, 2001, 73 (16) :3921-3926
[10]   Preparation and characterization of monolithic porous capillary columns loaded with chromatographic particles [J].
Dulay, MT ;
Kulkarni, RP ;
Zare, RN .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :5103-5107