Experimental and Clinical Evidence Supporting Septectomy in the Primary Treatment of Acute Type B Thoracic Aortic Dissection

被引:29
作者
Berguer, Ramon [1 ]
Parodi, Juan C. [2 ]
Schlicht, Marty [1 ]
Khanafer, Khalil [1 ]
机构
[1] Univ Michigan Hlth Syst, Frankel Cardiovasc Ctr, Vasc Mech Lab, Ann Arbor, MI 48109 USA
[2] Trinidad Hosp, Dept Vasc Surg, Buenos Aires, DF, Argentina
关键词
FALSE LUMEN PRESSURE; EX-VIVO MODEL; TEAR SIZE; EXPERIENCE; DISEASE;
D O I
10.1016/j.avsg.2014.10.001
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: We reviewed the mechanics involved in the aneurysmal dilatation of the false lumen (FL) in type B aortic dissection and the experimental and clinical evidence supporting the proposition that the main agent for this dilatation is a differential of pressure between the false and true lumena. This difference in pressure is the consequence of a restricted outflow of the FL. Our aim was to study the relationship between the size of a septectomy that increases the outflow of the FL and its effect on the values of the differential of pressure. Methods: A bench-top model of aortic dissection was used to determine the relationship between the area of the tears and the value of the pressure differential. A range of tear sizes was tested. Results: The highest differential of pressure (6.77 mm Hg) was found with a single proximal tear. The addition of a distal tear decreases the pressure difference. The greater the sum of the areas of proximal and distal tears, the lower the pressure difference between true lumen and FL. This pressure difference approached zero, as the sum of the areas approached 250 mm(2). Conclusions: A septectomy of at least 250 mm(2), initiated from the distal tear to the proximal aorta of an area, should be part of the initial treatment of acute aortic dissection. Concomitant with it, the proximal tear should be occluded with either a bare stent or a stent graft.
引用
收藏
页码:167 / 173
页数:7
相关论文
共 18 条
[1]   Long-term results of the treatment of aortic graft infection by in situ replacement with femoral popliteal vein grafts [J].
Ali, Ahsan T. ;
Modrall, J. Gregory ;
Hocking, Jennie ;
Valentine, R. James ;
Spencer, Horace ;
Eidt, John F. ;
Clagett, G. Patrick .
JOURNAL OF VASCULAR SURGERY, 2009, 50 (01) :30-39
[2]   Aortic dissection: Perspectives in the era of stent-graft repair [J].
Atkins, MD ;
Black, JH ;
Cambria, RP .
JOURNAL OF VASCULAR SURGERY, 2006, 43 :30A-43A
[3]  
CARLSON RE, 1977, ARCH SURG-CHICAGO, V112, P1389
[4]   Review of Direct Anatomical Open Surgical Management of Atherosclerotic Aorto-Iliac Occlusive Disease [J].
Chiu, K. W. H. ;
Davies, R. S. M. ;
Nightingale, P. G. ;
Bradbury, A. W. ;
Adam, D. J. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2010, 39 (04) :460-471
[5]   In Vitro Characterisation of Physiological and Maximum Elastic Modulus of Ascending Thoracic Aortic Aneurysms Using Uniaxial Tensile Testing [J].
Duprey, A. ;
Khanafer, K. ;
Schlicht, M. ;
Avril, S. ;
Williams, D. ;
Berguer, R. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2010, 39 (06) :700-707
[6]   LONG-TERM EXPERIENCE WITH DESCENDING AORTIC DISSECTION - THE COMPLICATION-SPECIFIC APPROACH [J].
ELEFTERIADES, JA ;
HARTLEROAD, J ;
GUSBERG, RJ ;
SALAZAR, AM ;
BLACK, HR ;
KOPF, GS ;
BALDWIN, JC ;
HAMMOND, GL .
ANNALS OF THORACIC SURGERY, 1992, 53 (01) :11-21
[7]   The International Registry of Acute Aortic Dissection (IRAD) - New insights into an old disease [J].
Hagan, PG ;
Nienaber, CA ;
Isselbacher, EM ;
Bruckman, D ;
Karavite, DJ ;
Russman, PL ;
Evangelista, A ;
Fattori, R ;
Suzuki, T ;
Oh, JK ;
Moore, AG ;
Malouf, JF ;
Pape, LA ;
Gaca, C ;
Sechtem, U ;
Lenferink, S ;
Deutsch, HJ ;
Diedrichs, H ;
Robles, JMY ;
Llovet, A ;
Gilon, D ;
Das, SK ;
Armstrong, WF ;
Deeb, GM ;
Eagle, KA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2000, 283 (07) :897-903
[8]   Effects of strain rate, mixing ratio, and stress-strain definition on the mechanical behavior of the polydimethylsiloxane (PDMS) material as related to its biological applications [J].
Khanafer, Khalil ;
Duprey, Ambroise ;
Schlicht, Marty ;
Berguer, Ramon .
BIOMEDICAL MICRODEVICES, 2009, 11 (02) :503-508
[9]   Aortic fenestration for acute or chronic aortic dissection: An uncommon but effective procedure [J].
Panneton, JM ;
Teh, SH ;
Cherry, KJ ;
Hofer, JM ;
Gloviczki, P ;
Andrews, JC ;
Bower, TC ;
Pairolero, PC ;
Hallett, JW .
JOURNAL OF VASCULAR SURGERY, 2000, 32 (04) :711-720
[10]   Intra-aneurysmal pressure after incomplete endovascular exclusion [J].
Parodi, JC ;
Berguer, R ;
Ferreira, LM ;
La Mura, R ;
Schermerhorn, ML .
JOURNAL OF VASCULAR SURGERY, 2001, 34 (05) :909-914