Effect of thermal bridges on transmission loads and thermal resistance of building walls under dynamic conditions

被引:52
作者
Al-Sanea, Sami A. [1 ]
Zedan, M. F. [1 ]
机构
[1] King Saud Univ, Dept Mech Engn, Coll Engn, Riyadh 11421, Saudi Arabia
关键词
Thermal bridges; Mortar joints; Transmission load; R-value; Wall thermal performance; HEAT-TRANSFER; INSULATION; SPACES; FLOW;
D O I
10.1016/j.apenergy.2012.04.038
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Mortar joints which cut across insulation layers in building walls act as thermal bridges that increase transmission loads and reduce wall thermal resistance (R-value). A computer model based on the finite-volume method, which has been previously validated, is used to quantify effects of mortar joints height (H-mj) on thermal performance of building walls under two-dimensional steady-periodic conditions using the climatic data of Riyadh. Results show that for a typical wall with insulation thickness of 75 mm, mortar joints with H-mj = 10 mm (4.8% thermal bridge area) increase peak, daily, and yearly cooling and heating transmission loads by 62%, while the wall R-value decreases by 38% compared to similar wall with no mortar joints (H-mj = 0). The transmissions loads increase by 103% and the R-value decreases by 51% for H-mj = 20 mm (9.1% thermal bridge area). These percentages would drastically increase building air-conditioning loads and energy consumption. Thermal bridges are also shown to appreciably increase the decrement factor causing higher inner surface temperature and transmission load fluctuations. It is strongly recommended that thermal bridging effects should be minimized, if not eliminated, through proper design practices and that, when unavoidably present, must be given due consideration in thermal analysis and must be accounted for. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:584 / 593
页数:10
相关论文
共 35 条
[1]   THE EFFECT OF AIR CELLS AND MORTAR JOINTS ON THE THERMAL-RESISTANCE OF CONCRETE MASONRY WALLS [J].
ABDOU, OA ;
MURALI, KS .
ENERGY AND BUILDINGS, 1994, 21 (02) :111-119
[2]  
Al-Sanea S. A., 1995, Journal of King Saud University (Engineering Sciences), V7, P219
[3]   Heat transfer characteristics and optimum insulation thickness for Hordi roofs using a pseudo one-dimensional dynamic model [J].
Al-Sanea, S. A. ;
Zedan, M. F. .
INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2006, 27 (02) :85-98
[4]  
Al-Sanea S.A., 2003, Journal of Building Physics, V26, P285, DOI [10.1177/109719603027973, DOI 10.1177/109719603027973]
[5]   Adjustment factors for the ASHRAE clear-sky model based on solar-radiation measurements in Riyadh [J].
Al-Sanea, SA ;
Zedan, MF ;
Al-Ajlan, SA .
APPLIED ENERGY, 2004, 79 (02) :215-237
[6]   Finite-volume thermal analysis of building roofs under two-dimensional periodic conditions [J].
Al-Sanea, SA .
BUILDING AND ENVIRONMENT, 2003, 38 (08) :1039-1049
[7]   Optimized monthly-fixed thermo stat-setting scheme for maximum energy-savings and thermal comfort in air-conditioned spaces [J].
Al-Sanea, Sami A. ;
Zedan, M. F. .
APPLIED ENERGY, 2008, 85 (05) :326-346
[8]  
Ascione F, APPL ENERGY IN PRESS
[9]  
Asdrubali F., APPL ENERGY IN PRESS
[10]  
*ASHRAE INC, 1997, HDB FUND