Determination of chromium(III) and chromium(VI) in mineral water by bidirectional electrostacking and electrothermal atomic absorption spectrometry

被引:23
作者
He, YZ
Cervera, ML
Pastor, A
de la Guardia, M
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Valencia, Spain
[2] Univ Sci & Technol China, Dept Chem, Hefei 230026, Anhui, Peoples R China
关键词
chromium speciation; bidirectional electrostacking; electrothermal atomic absorption; mineral water;
D O I
10.1016/S0003-2670(01)01296-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A feasibility investigation was carried out on the use of bidirectional electrostacking for simultaneous separation and pre-concentration of Cr(III) and Cr(VI) and their electrothermal atomic absorption spectrometry (ETAAS) determination. The bidirectional electrostacking manifold was improved, and the effects of sample tube cross-section and electrostacking time on the pre-concentration factor were investigated. Results indicate that the sample tube cross-section and electrostacking time are the main influence factors on the electrostacking pre-concentration, as well as the electric field strength and ionic mobility. The method developed was suitable for the simultaneous separation and pre-concentration of micro- or trace cations and anions in low conductivity sample solutions. The dynamic calibration range for both, Cr(III) and Cr(VI), was from 0.5 to 10 mug l(-1) using 20 mul sample volume and ETAAS determination. Standard addition method was used for the pre-concentration of Cr(III) and Cr(VI) in electrostacking procedure. The amounts of 100 ng l(-1) Cr(III) and Cr(VI) were added into one of twin samples, which were pre-concentrated in parallel, for the pre-concentration factor calculation. The limit of detection for Cr(III) and Cr(VI) was 6 and 5 ng l(-1), respectively, for three times standard deviation (S.D.) of blank values (n = 7) and 10 min electrostacking, providing pre-concentration factors of the order of 10 times. The method was applied to analyze a certified reference material of simulated fresh water, and results were coincident with its certified value. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 11 条
  • [1] Chien R. L., 1992, ANAL CHEM, V64, P489
  • [2] Improvement on simultaneous determination of chromium species in aqueous solution by ion chromatography and chemiluminescence detection
    Gammelgaard, B
    Liao, YP
    Jons, O
    [J]. ANALYTICA CHIMICA ACTA, 1997, 354 (1-3) : 107 - 113
  • [3] Mechanism of porous core electroosmotic pump flow injection system and its application to determination of chromium(VI) in waste-water
    Gan, WE
    Yang, L
    He, YZ
    Zeng, RH
    Cervera, ML
    de la Guardia, M
    [J]. TALANTA, 2000, 51 (04) : 667 - 675
  • [4] HE Y, 1998, Patent No. 972121269
  • [5] On-line bidirectional electrostacking of chromium(III) and chromium(VI) for flame atomic absorption spectrometry determination
    He, YZ
    Cervera, ML
    Garrido-Ecija, MI
    de la Guardia, M
    [J]. ANALYTICA CHIMICA ACTA, 2000, 421 (01) : 57 - 65
  • [6] HE YZ, 1998, CHINESE J ANAL CHEM, V26, P125
  • [7] Cr(III)/Cr(VI) determination in waste water by ICP/AES with on-line HPLC (HHPN) sample introduction
    Luo, SK
    Berndt, H
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (05): : 545 - 549
  • [8] ISOTACHOPHORESIS AS AN ONLINE CONCENTRATION PRETREATMENT TECHNIQUE IN CAPILLARY ELECTROPHORESIS
    STEGEHUIS, DS
    IRTH, H
    TJADEN, UR
    VANDERGREEF, J
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 538 (02): : 393 - 402
  • [9] FACTORS INFLUENCING TRACE ION ANALYSIS WITH PRECONCENTRATION BY ELECTROSTACKING
    WOJTUSIK, MJ
    HARROLD, MP
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1994, 671 (1-2) : 411 - 417
  • [10] Yang L, 2000, CHINESE J ANAL CHEM, V28, P248