Scanning electron microscopy of human cortical bone failure surfaces

被引:55
作者
Braidotti, P
Branca, FP
Stagni, L
机构
[1] UNIV ROMA LA SAPIENZA,DIPARTIMENTO MECCAN & AERONAUT,ROME,ITALY
[2] UNIV ROMA LA SAPIENZA,CLIN ORTOPED,ROME,ITALY
[3] UNIV ROME,IST NAZL FIS MAT,DIPARTIMENTO MECCAN & AUTOMAT TERZA,ROME,ITALY
关键词
bone; lamellae; fractography; scanning electron microscopy; composite materials;
D O I
10.1016/S0021-9290(96)00102-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Undecalcified samples extracted from human femoral shafts are fractured by bending and the fracture surfaces are examined with a scanning electron microscope (SEM). The investigation is performed on both dry and wet (hydrated with a saline solution) specimens. SEM micrographs show patterns in many respects similar to those observed in fractography studies of laminated fiber-reinforced synthetic composites. In particular, dry and wet samples behave like brittle and ductile matrix laminates, respectively. An analysis carried out on the basis of the mechanisms that dominate the fracture process of laminates shows that a reasonable cortical bone model is that of a laminated composite material whose matrix is composed of extracellular noncollagenous calcified proteins, and the reinforcement is constituted by the calcified collagen fiber system. Copyright (C) 1996 Elsevier Science Ltd.
引用
收藏
页码:155 / 162
页数:8
相关论文
共 35 条
[1]  
Adams D.F., 1967, Journal of Composite Materials, V1, P4, DOI [10.1177/002199836700100102, DOI 10.1177/002199836700100102]
[2]  
[Anonymous], COMPOS MATER SERIES
[3]  
[Anonymous], 1976, ADV BIOENG
[4]   MECHANICAL SIMILARITIES BETWEEN ALTERNATE OSTEONS AND CROSS-PLY LAMINATES [J].
ASCENZI, A ;
BONUCCI, E .
JOURNAL OF BIOMECHANICS, 1976, 9 (02) :65-&
[5]   TENSILE PROPERTIES OF SINGLE OSTEONS [J].
ASCENZI, A ;
BONUCCI, E .
ANATOMICAL RECORD, 1967, 158 (04) :375-&
[6]   THE BENDING PROPERTIES OF SINGLE OSTEONS [J].
ASCENZI, A ;
BASCHIERI, P ;
BENVENUTI, A .
JOURNAL OF BIOMECHANICS, 1990, 23 (08) :763-&
[7]   COMPRESSIVE PROPERTIES OF SINGLE OSTEONS [J].
ASCENZI, A ;
BONUCCI, E .
ANATOMICAL RECORD, 1968, 161 (03) :377-&
[8]   ORIENTATION OF COLLAGEN-FIBERS AT THE BOUNDARY BETWEEN 2 SUCCESSIVE OSTEONIC LAMELLAE AND ITS MECHANICAL INTERPRETATION [J].
ASCENZI, A ;
BENVENUTI, A .
JOURNAL OF BIOMECHANICS, 1986, 19 (06) :455-463
[9]  
Beaumont P.W.R., 1990, DELAWARE COMPOSITES, V4
[10]  
Bonfield W, 1989, COMPOSITE MAT SERIES, V6, P615