Quantitative determination of trace phenazopyridine in human urine samples by hyphenation of dispersive solid-phase extraction and liquid-phase microextraction followed by gas chromatography/mass spectrometry analysis

被引:5
作者
Seidi, Shahram [1 ]
Mohammadi, Fahimeh [1 ]
Tajik, Mohammad [2 ]
Baharfar, Mahroo [2 ]
Mohammadi, Abdorreza [3 ]
Otoufat, Tohid [1 ]
机构
[1] KN Toosi Univ Technol, Fac Chem, Dept Analyt Chem, POB 16315-1618, Tehran, Iran
[2] Tarbiat Modares Univ, Dept Chem, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Natl Nutr & Food Technol Res Inst, Fac Nutr Sci Food Sci & Technol, Dept Food Sci & Technol, Tehran, Iran
关键词
dispersive solid phase extraction; magnetic graphene oxide; microextraction; phenazopyridine; urine; COATED FE3O4 NANOPARTICLES; MAGNETIC GRAPHENE OXIDE; HUMAN PLASMA; POLYPYRROLE-POLYTHIOPHENE; HYDROCHLORIDE; SILVER(I); GOLD(III); MS;
D O I
10.1002/jssc.202000055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Magnetic dispersive solid-phase extraction followed by dispersive liquid-liquid microextraction coupled with gas chromatography/mass spectrometry was applied for the quantitative analysis of phenazopyridine in urinary samples. Magnetic dispersive solid-phase extraction was carried out using magnetic graphene oxide nanoparticles modified by poly(thiophene-pyrrole) copolymer. The eluting solvent of this step was used as the disperser solvent for the dispersive liquid-liquid microextraction procedure. To reach the maximum efficiency of the method, effective parameters including sorbent amount, adsorption time, type and volume of disperser and extraction solvents, pH of the sample solution, and ionic strength as well as desorption time, and approach were optimized, separately. Characterization of the synthesized sorbent was studied by utilizing infrared spectroscopy, scanning electron microscopy, and energy-dispersive X-ray analysis. Calibration curve was linear in the range of 0.5-250 ng/mL (R-2 = 0.9988) with limits of detection and quantification of 0.1 and 0.5 ng/mL, respectively. Intra- and interday precisions (RSD%, n = 3) of the method were in the range of 4.6-5.4% and 4.0-5.5%, respectively, at three different concentration levels. Under the optimal condition, this method was successfully applied for the determination of phenazopyridine in human urine samples. The relative recoveries were obtained in the range of 85.0-89.0%.
引用
收藏
页码:2897 / 2904
页数:8
相关论文
共 50 条
  • [41] A revised method for determination of dialkylphosphate levels in human urine by solid-phase extraction and liquid chromatography with tandem mass spectrometry: application to human urine samples from Japanese children
    Ueyama, Jun
    Saito, Isao
    Takaishi, Ayuko
    Nomura, Hiroshi
    Inoue, Mai
    Osaka, Aya
    Sugiura, Yuka
    Hayashi, Yumi
    Wakusawa, Shinya
    Ogi, Hiroko
    Inuzuka, Kimio
    Kamijima, Michihiro
    Kondo, Takaaki
    ENVIRONMENTAL HEALTH AND PREVENTIVE MEDICINE, 2014, 19 (06) : 405 - 413
  • [42] Magnetic graphene dispersive solid phase extraction-ultra performance liquid chromatography tandem mass spectrometry for determination of β-agonists in urine
    Wang, Geng Nan
    Wu, Ning Peng
    He, Xin
    Zhang, Hui Cai
    Liu, Jing
    Wang, Jian Ping
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1067 : 18 - 24
  • [43] Analysis of molluscicide metaldehyde in vegetables by dispersive solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Zhang, H. Y.
    Wang, C.
    Xu, P. J.
    Ma, Y. Q.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2011, 28 (08): : 1034 - 1040
  • [44] Estrogens and their conjugates: Determination in water samples by solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Pedrouzo, Marta
    Borrull, Francesc
    Pocurull, Eva
    Maria Marce, Rosa
    TALANTA, 2009, 78 (4-5) : 1327 - 1331
  • [45] DETERMINATION OF HERBICIDES IN SOIL BY DISPERSIVE SOLID-PHASE EXTRACTION, DISPERSIVE LIQUID-LIQUID MICROEXTRACTION, AND HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
    Tang, Ming
    Li, Lichun
    Zhong, Qiuzan
    Zhang, Guobin
    Feng, Xiujie
    Deng, Songqing
    Wan, Shuqing
    ANALYTICAL LETTERS, 2014, 47 (18) : 2871 - 2881
  • [46] Determination of pyrethroids in water samples by dispersive solid-phase extraction coupled with high-performance liquid chromatography
    Zhang, Jie
    Wang, Ya
    Yu, Jun
    Wang, Qingying
    Khattak, Kashif Nawaz
    Yang, Xiupei
    WATER ENVIRONMENT RESEARCH, 2022, 94 (11)
  • [47] Quantitative analysis of menthol in human urine using solid phase microextraction and stable isotope dilution gas chromatography-mass spectrometry
    Huang, Wenlin
    Blount, Benjamin C.
    Watson, Clifford H.
    Watson, Christina
    Chambers, David M.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1044 : 200 - 205
  • [48] Solid-phase extraction followed by liquid chromatography-tandem mass spectrometry for the determination of hydroxylated benzophenone UV absorbers in environmental water samples
    Negreira, N.
    Rodriguez, I.
    Ramil, M.
    Rubi, E.
    Cela, R.
    ANALYTICA CHIMICA ACTA, 2009, 654 (02) : 162 - 170
  • [49] Solid-phase dispersive extraction method for analysis of benzodiazepine drugs in serum and urine samples
    Saito, Koichi
    Kikuchi, Yuu
    Saito, Rieko
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 100 : 28 - 32
  • [50] DETERMINATION OF VOLATILES IN MOUSE URINE BY HEADSPACE SOLID PHASE MICROEXTRACTION AND GAS CHROMATOGRAPHY-MASS SPECTROMETRY
    Arnaiz, Esther
    Moreno, Daniel
    Quesada, Roberto
    ANALYTICAL LETTERS, 2014, 47 (05) : 721 - 729