Quantitative determination of trace phenazopyridine in human urine samples by hyphenation of dispersive solid-phase extraction and liquid-phase microextraction followed by gas chromatography/mass spectrometry analysis

被引:7
作者
Seidi, Shahram [1 ]
Mohammadi, Fahimeh [1 ]
Tajik, Mohammad [2 ]
Baharfar, Mahroo [2 ]
Mohammadi, Abdorreza [3 ]
Otoufat, Tohid [1 ]
机构
[1] KN Toosi Univ Technol, Fac Chem, Dept Analyt Chem, POB 16315-1618, Tehran, Iran
[2] Tarbiat Modares Univ, Dept Chem, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Natl Nutr & Food Technol Res Inst, Fac Nutr Sci Food Sci & Technol, Dept Food Sci & Technol, Tehran, Iran
关键词
dispersive solid phase extraction; magnetic graphene oxide; microextraction; phenazopyridine; urine; COATED FE3O4 NANOPARTICLES; MAGNETIC GRAPHENE OXIDE; HUMAN PLASMA; POLYPYRROLE-POLYTHIOPHENE; HYDROCHLORIDE; SILVER(I); GOLD(III); MS;
D O I
10.1002/jssc.202000055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Magnetic dispersive solid-phase extraction followed by dispersive liquid-liquid microextraction coupled with gas chromatography/mass spectrometry was applied for the quantitative analysis of phenazopyridine in urinary samples. Magnetic dispersive solid-phase extraction was carried out using magnetic graphene oxide nanoparticles modified by poly(thiophene-pyrrole) copolymer. The eluting solvent of this step was used as the disperser solvent for the dispersive liquid-liquid microextraction procedure. To reach the maximum efficiency of the method, effective parameters including sorbent amount, adsorption time, type and volume of disperser and extraction solvents, pH of the sample solution, and ionic strength as well as desorption time, and approach were optimized, separately. Characterization of the synthesized sorbent was studied by utilizing infrared spectroscopy, scanning electron microscopy, and energy-dispersive X-ray analysis. Calibration curve was linear in the range of 0.5-250 ng/mL (R-2 = 0.9988) with limits of detection and quantification of 0.1 and 0.5 ng/mL, respectively. Intra- and interday precisions (RSD%, n = 3) of the method were in the range of 4.6-5.4% and 4.0-5.5%, respectively, at three different concentration levels. Under the optimal condition, this method was successfully applied for the determination of phenazopyridine in human urine samples. The relative recoveries were obtained in the range of 85.0-89.0%.
引用
收藏
页码:2897 / 2904
页数:8
相关论文
共 39 条
[1]   PHENAZOPYRIDINE-INDUCED HEPATITIS [J].
BADLEY, BWD .
BRITISH MEDICAL JOURNAL, 1976, 2 (6040) :850-850
[2]   Microextraction of antidepressant drugs into syringes packed with a nanocomposite consisting of polydopamine, silver nanoparticles and polypyrrole [J].
Bagheri, Habib ;
Banihashemi, Solmaz ;
Zandian, Faezeh Karimi .
MICROCHIMICA ACTA, 2016, 183 (01) :195-202
[3]   Conductive polymer-based microextraction methods: A review [J].
Bagheri, Habib ;
Ayazi, Zahra ;
Naderi, Mehrnoush .
ANALYTICA CHIMICA ACTA, 2013, 767 :1-13
[4]   The Use of Magnetic Nanoparticles in Analytical Chemistry [J].
Beveridge, Jacob S. ;
Stephens, Jason R. ;
Williams, Mary Elizabeth .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 4, 2011, 4 :251-273
[5]  
Can M, 2003, ACTA CHIM SLOV, V50, P741
[6]   Development and validation of a gas chromatography-mass Spectrometry method for the determination of Phenazopyridine in rat plasma: Application to the pharmacokinetic study [J].
Chen, Qinhua ;
Li, Kaijun ;
Zhang, Zhuo ;
Li, Peng ;
Liu, Jia ;
Li, Qiang .
BIOPHARMACEUTICS & DRUG DISPOSITION, 2007, 28 (08) :439-444
[7]   Sample treatments based on dispersive (micro)extraction [J].
Cruz-Vera, M. ;
Lucena, R. ;
Cardenas, S. ;
Valcarcel, M. .
ANALYTICAL METHODS, 2011, 3 (08) :1719-1728
[8]   Recent advances and trends in miniaturized sample preparation techniques [J].
da Silva Burato, Juliana Soares ;
Vargas Medina, Deyber Arley ;
de Toffoli, Ana Lucia ;
Soares Maciel, Edvaldo Vasconcelos ;
Lancas, Fernando Mauro .
JOURNAL OF SEPARATION SCIENCE, 2020, 43 (01) :202-225
[9]   Determination of phenazopyridine in human plasma by high performance liquid chromatography [J].
Farin, D ;
Piva, G ;
Kitzes-Cohen, R .
CHROMATOGRAPHIA, 2000, 52 (3-4) :179-180
[10]   Determination of phenazopyridine in biological fluids using electromembrane extraction followed by high-performance liquid chromatography [J].
Fotouhi, Lida ;
Yamini, Yadollah ;
Hosseini, Razieh ;
Rezazadeh, Maryam .
CANADIAN JOURNAL OF CHEMISTRY, 2015, 93 (07) :702-707