Quality of treatment plans and accuracy of in vivo portal dosimetry in hybrid intensity-modulated radiation therapy and volumetric modulated arc therapy for prostate cancer

被引:9
作者
Bedford, James L.
Smyth, Gregory
Hanson, Ian M.
Tree, Alison C.
Dearnaley, David P.
Hansen, Vibeke N.
机构
[1] Inst Canc Res, London, England
[2] Royal Marsden NHS Fdn Trust, London, England
关键词
IMRT; VMAT; Prostate; Treatment planning; Portal dosimetry; CONFORMAL RADIOTHERAPY; INTRAFRACTION MOTION; HELICAL TOMOTHERAPY; EPID DOSIMETRY; VERIFICATION; IMRT; VMAT; TIME;
D O I
10.1016/j.radonc.2016.07.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Delivering selected parts of volumetric modulated arc therapy (VMAT) plans using step-and-shoot intensity modulated radiotherapy (IMRT) beams has the potential to increase plan quality by allowing specific aperture positioning. This study investigates the quality of treatment plans and the accuracy of in vivo portal dosimetry in such a hybrid approach for the case of prostate radiotherapy. Material and methods: Conformal and limited-modulation VMAT plans were produced, together with five hybrid IMRT/VMAT plans, in which 0%, 25%, 50%, 75% or 100% of the segments were sequenced for IMRT, while the remainder were sequenced for VMAT. Integrated portal images were predicted for the plans. The plans were then delivered as a single hybrid beam using an Elekta Synergy accelerator with Agility head to a water-equivalent phantom and treatment time, isocentric dose and portal images were measured. Results: Increasing the IMRT percentage improves dose uniformity to the planning target volume (p < 0.01 for 50% IMRT or more), substantially reduces the volume of rectum irradiated to 65 Gy (p = 0.02 for 25% IMRT) and increases the monitor units (p < 0.001). Delivery time also increases substantially. All plans show accurate delivery of dose and reliable prediction of portal images. Conclusions: Hybrid IMRT/VMAT can be efficiently planned and delivered as a single beam sequence. Beyond 25% IMRT, the delivery time becomes unacceptably long, with increased risk of intrafraction motion, but 25% IMRT is an attractive compromise. Integrated portal images can be used to perform in vivo dosimetry for this technique. (C) 2016 The Royal Marsden NHS Foundation Trust. Published by Elsevier Ireland Ltd.
引用
收藏
页码:320 / 326
页数:7
相关论文
共 33 条
  • [11] Earl M. A., 2004, United States Patent Application Publication, Patent No. [2004/0071261, 20040071261]
  • [12] Parameters for the Lyman Kutcher Burman (LKB) model of Normal Tissue Complication Probability (NTCP) for specific rectal complications observed in clinical practise
    Gulliford, Sarah L.
    Partridge, Mike
    Sydes, Matthew R.
    Webb, Steve
    Evans, Philip M.
    Dearnaley, David P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 102 (03) : 347 - 351
  • [13] Time dependence of intrafraction patient motion assessed by repeat stereoscopic imaging
    Hoogeman, Mischa S.
    Nuyttens, Joost J.
    Levendag, Peter C.
    Heumen, Ben J. M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (02): : 609 - 618
  • [14] Class solutions for conformal external beam prostate radiotherapy
    Khoo, VS
    Bedford, JL
    Webb, S
    Dearnaley, DP
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (04): : 1109 - 1120
  • [15] Correlation between dosimetric effect and intrafraction motion during prostate treatments delivered with helical tomotherapy
    Langen, Katja M.
    Lu, Weiguo
    Ngwa, Wilfred
    Willoughby, Twyla R.
    Chauhan, Bhavin
    Meeks, Sanford L.
    Kupelian, Patrick A.
    Olivera, Gustavo
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (24) : 7073 - 7086
  • [16] Reduction of prostate intrafractional motion from shortening the treatment time
    Li, Jin Sheng
    Lin, Mu-Han
    Buyyounouski, Mark K.
    Horwitz, Eric M.
    Ma, Chang-Ming
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (14) : 4921 - 4932
  • [17] 3D Dosimetric verification of volumetric-modulated arc therapy by portal dosimetry
    Mans, Anton
    Remeijer, Peter
    Olaciregui-Ruiz, Igor
    Wendling, Markus
    Sonke, Jan-Jakob
    Mijnheer, Ben
    van Herk, Marcel
    Stroom, Joep C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 94 (02) : 181 - 187
  • [18] Dosimetric comparison of helical tomotherapy, RapidArc, and a novel IMRT & Arc technique for esophageal carcinoma
    Martin, Spencer
    Chen, Jeff Z.
    Dar, A. Rashid
    Yartsev, Slav
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 101 (03) : 431 - 437
  • [19] FusionArc optimization: A hybrid volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) planning strategy
    Matuszak, Martha M.
    Steers, Jennifer M.
    Long, Troy
    McShan, Daniel L.
    Fraass, Benedick A.
    Romeijn, H. Edwin
    Ten Haken, Randall K.
    [J]. MEDICAL PHYSICS, 2013, 40 (07)
  • [20] Replacing pretreatment verification with in vivo EPID dosimetry for prostate IMRT
    McDermott, Leah N.
    Wendling, Markus
    Sonke, Jan-Jakob
    van Herk, Marcel
    Mijnheer, Ben J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (05): : 1568 - 1577