Predictive value of echocardiography and its relation to Kt/V and anthropometric parameters in hemodialysis patients

被引:8
作者
Stosovic, Milan D. [1 ]
Petrovic, Milan Z. [2 ,3 ]
Vujisic-Tesic, Bosiljka D. [2 ,3 ]
Stanojevic, Mirjana Lj [1 ]
Simic-Ogrizovic, Sanja P. [1 ,3 ]
Jovanovic, Dijana B. [1 ,3 ]
Naumovic, Radomir T. [1 ,3 ]
机构
[1] Clin Ctr Serbia, Clin Nephrol, Beograd 11000, Serbia
[2] Clin Ctr Serbia, Clin Cardiol, Beograd 11000, Serbia
[3] Univ Belgrade, Fac Med, Belgrade, Serbia
关键词
Adequacy; anthropometry; hemodialysis; Kt/V; nutrition; retrospective study; survival analysis; STAGE RENAL-DISEASE; MORTALITY; SURVIVAL;
D O I
10.3109/0886022X.2015.1007821
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: In order to evaluate the predictive value of echocardiograph parameters for mortality of hemodialysis patients and their relation to Kt/V and anthropometry, a prospective, single center study was analyzed post-hoc. Methods: This analysis encompassed 106 patients on maintenance hemodialysis monitored for 108 months from 1996 to 2004. spKt/V was calculated using the Daugirdas formula. Anthropometric measurements included mid-arm muscle measurements (MAMC) and percentage of body fat (% fat). Echocardiography included the estimations of left ventricular wall thickness, dimensions and volumes (EDV, ESV), systolic LV function (ejection fraction -EFLV, fractional shortening - VCF, stroke volume - SV) and diastolic LV function (E/A, VTI-A wave of transmitral flow velocity), left atrial diameter, as well as assessment of clinical and biochemical parameters. The Cox proportional hazard model was used to estimate predictive values of echocardiograph parameters. Results: Kt/V correlated significantly with left ventricular systolic and diastolic volumes and function, septal and posterior wall thickness and left atrium dimension. MAMC and % fat also correlated with many echocardiograph parameters. Multivariate Cox regression selected age [HR 1.07; CI (1.03-1.12); p < 0.01], albumin [HR 0.88; CI (0.79-0.97); p < 0.05] and left atrium dimension -binary [values > 4 cm were marked as "1" and others "0" - HR 3.76; CI (1.56-9.03); p < 0.01] as independent predictors of death. Conclusion: Left atrium dimension was the most important predictor of mortality among the echocardiograph parameters. Many of these parameters were related to Kt/V and anthropometric measurements and could be the combined consequence of hypervolemia and hypertension.
引用
收藏
页码:589 / 596
页数:8
相关论文
共 24 条
  • [1] [Anonymous], 2000, AM J KIDNEY DIS S, V35, pS76
  • [2] [Anonymous], BOD MASS IND MEAS CH
  • [3] [Anonymous], 2010, Am J Kidney Dis, V55, pS1, DOI DOI 10.1053/S0272-6386(10)00603-7
  • [4] Relationship of dose of hemodialysis and cause-specific mortality
    Bloembergen, WE
    Stannard, DC
    Port, FK
    Wolfe, RA
    Pugh, JA
    Jones, CA
    Greer, JW
    Golper, TA
    Held, PJ
    [J]. KIDNEY INTERNATIONAL, 1996, 50 (02) : 557 - 565
  • [5] BMI, spKt/V, and SBP but Not DBP Are Related to LVH in Chinese Maintenance Hemodialysis Patients
    Cao, XueSen
    Zou, JianZhou
    Teng, Jie
    Zhong, YiHong
    Ji, Jun
    Chen, ZhangWei
    Liu, ZhongHua
    Shen, Bo
    Ding, XiaoQiang
    [J]. RENAL FAILURE, 2011, 33 (03) : 269 - 275
  • [6] Echocardiography in Hemodialysis Patients: Uses and Challenges
    Chiu, Diana Y. Y.
    Green, Darren
    Abidin, Nik
    Sinha, Smeeta
    Kalra, Philip A.
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2014, 64 (05) : 804 - 816
  • [7] DAUGIRDAS JT, 1993, J AM SOC NEPHROL, V4, P1205
  • [8] Epidemiology of end-stage renal disease and current status of hemodialysis in Yugoslavia
    Djukanovic, L
    Radovic, M
    Bakovic, J
    Budosan, I
    Bukvic, D
    Cveticanin, A
    Davinic, S
    Dragoljic, B
    Djordjevic, V
    Djuric, S
    Haviza-Lilic, B
    Ilic, M
    Janos, B
    Jelacic, R
    Jelic, S
    Kostic, N
    Mandic, M
    Ostric, V
    Pljesa, S
    Radisic, M
    Radojevic, M
    Rakic, N
    Rangelov, V
    Ratkovic, M
    Stojanovic, M
    Stojanovic, R
    Tintor, D
    Vasic, V
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2002, 25 (09) : 852 - 859
  • [9] Diastolic function is a strong predictor of mortality in patients with chronic kidney disease
    Farshid, Ahmad
    Pathak, Rajeev
    Shadbolt, Bruce
    Arnolda, Leonard
    Talaulikar, Girish
    [J]. BMC NEPHROLOGY, 2013, 14
  • [10] FOUQUE DF, 2004, REPLACEMENT RENAL FU, P1013