Uptake of I-131 in the biliary tract: A potential cause of a false-positive result of scintiscan

被引:18
作者
Carlisle, M
Cortes, A
McDougall, IR [1 ]
机构
[1] Stanford Hlth Serv, Div Nucl Med, Stanford, CA 94305 USA
[2] Miguel Servet Hosp, Div Nucl Med, Zaragoza, Spain
关键词
false-positive result; papillary cancer; radioiodine I-131 scintigraphy;
D O I
10.1097/00003072-199808000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Focal uptake of I-131 in the region of the liver was seen on whole-body scans in a 22-year-old asymptomatic woman who had invasive papillary cancer. Hepatic metastases were unlikely because of the clinical risk factors, and a CT scan of the liver was normal. By superimposing the I-131 scintiscan and a hepatobiliary scan, the site of the uptake was shown to be in the biliary tract, and it had migrated to the gallbladder on more delayed images. No pathologic cause was found.
引用
收藏
页码:524 / 527
页数:4
相关论文
共 13 条
[1]  
ACHONG DM, 1991, J NUCL MED, V32, P2275
[2]   False-positive radioiodine uptake in the abdomen and the pelvis: Radioiodine retention in the kidneys and review of the literature [J].
Bakheet, SMB ;
Hammami, MM ;
Powe, J .
CLINICAL NUCLEAR MEDICINE, 1996, 21 (12) :932-937
[3]   FALSE-POSITIVE I-131 BODY SCAN CAUSED BY A LARGE RENAL CYST [J].
BRACHMAN, MB ;
ROTHMAN, BJ ;
RAMANNA, L ;
TANASESCU, DE ;
ADELBERG, H ;
WAXMAN, AD .
CLINICAL NUCLEAR MEDICINE, 1988, 13 (06) :416-418
[4]  
BruckerDavis F, 1996, J NUCL MED, V37, P1690
[5]  
Fink-Bennett Darlene, 1996, P759
[6]  
LUBIN E, 1994, J NUCL MED, V35, P257
[7]   WHOLE-BODY SCINTIGRAPHY WITH RADIOIODINE-131 - A COMPREHENSIVE LIST OF FALSE-POSITIVES WITH SOME EXAMPLES [J].
MCDOUGALL, IR .
CLINICAL NUCLEAR MEDICINE, 1995, 20 (10) :869-875
[9]   FREQUENCY OF HEPATIC VISUALIZATION DURING I-131 IMAGING FOR METASTATIC THYROID-CARCINOMA [J].
ROSENBAUM, RC ;
JOHNSTON, GS ;
VALENTE, WA .
CLINICAL NUCLEAR MEDICINE, 1988, 13 (09) :657-660
[10]  
SCHALL LG, 1972, J NUCL MED, V13, P181