Inversion prepared coronary MR angiography:: Direct visualization of coronary blood flow

被引:7
作者
Katoh, M
Spuentrup, E
Stuber, M
Buecker, A
Manning, WJ
Günther, RW
Botnar, RM
机构
[1] Rhein Westfal TH Aachen, Univ Hosp, Dept Diagnost Radiol, D-52057 Aachen, Germany
[2] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[3] Harvard Univ, Sch Med, Boston, MA 02215 USA
[4] Johns Hopkins Univ, Sch Med, Dept Radiol, Div MRI Res, Baltimore, MD USA
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2005年 / 177卷 / 02期
关键词
coronary MRA; steady-state free-precession (SSFP); radial k-space sampling; slice-selective inversion; coronary blood flow;
D O I
10.1055/s-2005-857865
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Visualization of coronary blood flow by means of a slice-selective inversion pre-pulse in concert with bright-blood coronary MRA. Materials and Methods: Coronary magnetic resonance angiography (MRA) of the right coronary artery (RCA) was performed in eight healthy adult subjects on a 1.5 Tesla MR system (Gyroscan ACS-NT Philips Medical Systems, Best, NL) using a free-breathing navigator-gated and cardiac-triggered 3D steady-state free-precession (SSFP) sequence with radial k-space sampling. Imaging was performed with and without a slice-selective inversion pre-pulse, which was positioned along the main axis of the coronary artery but perpendicular to the imaging volume. Objective image quality parameters such as SNR, CNR, maximal visible vessel length, and vessel border definition were analyzed. Results: In contrast to conventional bright-blood 3D coronary MRA, the selective inversion pre-pulse provided a direct measure of coronary blood flow. In addition, CNR between the RCA and right ventricular blood pool was increased and the vessels had a tendency towards better delineation. Blood SNR and CNR between right coronary blood and epicardial fat were comparable in both sequences. Conclusion: The combination of a free-breathing navigator-gated and cardiac-triggered 3D SSFP sequence with a slice-selective inversion pre-pulse allows for direct and directional visualization of coronary blood flow with the additional benefit of improved contrast between coronary and right ventricular blood pool.
引用
收藏
页码:173 / 178
页数:6
相关论文
共 18 条
[1]   Comparison of gradient-echo and steady state free precession sequences for 3D-navigator MR angiography of coronary arteries [J].
Barkhausen, J ;
Hunold, P ;
Jochims, M ;
Eggebrecht, H ;
Sabin, GV ;
Erbel, R ;
Debatin, JF .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (06) :725-730
[2]  
Botnar RM, 2000, CIRCULATION, V102, P2582
[3]   Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA [J].
Botnar, RM ;
Stuber, M ;
Danias, PG ;
Kissinger, KV ;
Manning, WJ .
CIRCULATION, 1999, 99 (24) :3139-3148
[4]   3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries [J].
Deshpande, VS ;
Shea, SM ;
Laub, G ;
Simonetti, OP ;
Finn, JP ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :494-502
[5]   Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2 T [J].
Duerk, JL ;
Lewin, JS ;
Wendt, M ;
Petersilge, C .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :203-208
[6]   Soap-bubble visualization and quantitative analysis of 3D coronary magnetic resonance angiograms [J].
Etienne, A ;
Botnar, RM ;
van Muiswinkel, AMC ;
Boesiger, P ;
Manning, WJ ;
Stuber, M .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) :658-666
[7]  
Fayad ZA, 2000, CIRCULATION, V102, P506
[8]  
KATOH M, IN PRESS RADIOLOGY
[9]   Breath-hold signal-loss sequence for the qualitative assessment of flow disturbances in cardiovascular MR [J].
Keegan, J ;
Gatehouse, PD ;
John, AS ;
Mohiaddin, RH ;
Firmin, DN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (04) :496-501
[10]   Coronary magnetic resonance angiography for the detection of coronary stenoses [J].
Kim, WY ;
Danias, PG ;
Stuber, M ;
Flamm, SD ;
Plein, S ;
Nagel, E ;
Langerak, SE ;
Weber, OM ;
Pedersen, EM ;
Schmidt, M ;
Botnar, RM ;
Manning, WJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (26) :1863-1869