Comparison of magnetic resonance real-time imaging of left ventricular function with conventional magnetic resonance imaging and echocardiography

被引:98
作者
Schalla, S
Nagel, E
Lehmkuhl, H
Klein, C
Bornstedt, A
Schnackenburg, B
Schneider, U
Fleck, E
机构
[1] German Heart Inst Berlin, D-13353 Berlin, Germany
[2] Humboldt Univ, Berlin, Germany
[3] Philips Med Syst, Hamburg, Germany
关键词
D O I
10.1016/S0002-9149(00)01279-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study analyzes the accuracy of a new real-time magnetic resonance imaging (MRI) technique (acquisition duration, 62 ms/image) and echocardiography for the determination of left ventricular (LV) end-diastolic volume, endsystolic volume, election fraction, and muscle mass when compared with turbo gradient echo imaging as the reference standard. Thirty-four patients were examined with digital echocardiography, standard, and real-time MRI. A close correlation was found between the results of realtime imaging and the reference standard for end-diastolic volume, end-systolic volume, and election fraction (r >0.95), with a lower correlation for LV muscle mass (r = 0.81). Correlations between echocardiography and the reference standard were lower for all parameters, Realtime MRI enables the acquisition of high-quality cine loops of the entire heart in minimal time without electrocardiographic triggering or breath holding. Thus, patient setup and scan time can be reduced considerably. Results ore similar to the reference standard and superior to echocardiography for determining LV volumes and election fraction. This technique is a valid alternative to current approaches and can form the basis of every cardiac MRI examination. (C) 2001 by Excerpta Medica, Inc.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 18 条
[1]   Reproducibility of left ventricular size, shape and mass with echocardiography, magnetic resonance imaging and radionuclide angiography in patients with anterior wall infarction [J].
Baur, LHB ;
Schipperheyn, JJ ;
vanderVelde, EA ;
vanderWall, EE ;
Reiber, JHC ;
vanderGeest, RJ ;
vanDijkman, PRM ;
Gerritsen, JG ;
vanEckSmit, BLF ;
Voogd, PJ ;
Bruschke, AVG .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1996, 12 (04) :233-240
[2]   Accuracy and precision of angiographic volumetry methods for left and right ventricle [J].
Beier, J ;
Wellnhofer, E ;
Oswald, H ;
Fleck, E .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1996, 53 (02) :179-188
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Echocardiographic assessment of left ventricular remodeling: Are left ventricular diameters suitable tools? [J].
Dujardin, KS ;
EnriquezSarano, M ;
Rossi, A ;
Bailey, KR ;
Seward, JB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (06) :1534-1541
[5]   QUANTITATION OF HUMAN LEFT-VENTRICULAR MASS - AND VOLUME BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY - INVITRO ANATOMIC VALIDATION [J].
HELAK, JW ;
REICHEK, N .
CIRCULATION, 1981, 63 (06) :1398-1407
[6]   Comparison of quantitation of left ventricular volume, election fraction, and cardiac output in patients with atrial fibrillation by cine magnetic resonance imaging versus invasive measurements [J].
Hundley, WG ;
Meshack, BM ;
Willett, DL ;
Sayad, DE ;
Lange, RA ;
Willard, JE ;
Landau, C ;
Hillis, LD ;
Peshock, RM .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (10) :1119-1123
[7]   Normal human right and left ventricular mass, systolic function, and gender differences by cine magnetic resonance imaging [J].
Lorenz, CH ;
Walker, ES ;
Morgan, VL ;
Klein, SS ;
Graham, TP .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 1999, 1 (01) :7-21
[8]   The influence of through-plane motion on left ventricular volumes measured by magnetic resonance imaging:: Implications for image acquisition and analysis [J].
Marcus, JT ;
Götte, MJW ;
DeWaal, LK ;
Stam, MR ;
Van der Geest, RJ ;
Heethaar, RM ;
Van Rossum, AC .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 1999, 1 (01) :1-6
[9]   Assessment of left ventricular volume and mass by cine magnetic resonance imaging in patients with anterior myocardial infarction intra-observer and inter-observer variability on contour detection [J].
Matheijssen, NAA ;
Baur, LHB ;
Reiber, JHC ;
vanderVelde, EA ;
vanDijkman, PRM ;
vanderGeest, RJ ;
deRoos, A ;
vanderWall, EE .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1996, 12 (01) :11-19
[10]   ULTRAFAST INTERLEAVED GRADIENT-ECHO-PLANAR IMAGING ON A STANDARD SCANNER [J].
MCKINNON, GC .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (05) :609-616