In-plane tip deflection and force achieved with asymmetrical polysilicon electrothermal microactuators

被引:22
作者
Kolesar, ES [1 ]
Ko, SY [1 ]
Howard, JT [1 ]
Allen, PB [1 ]
Wilken, JM [1 ]
Boydston, NC [1 ]
Ruff, MD [1 ]
Wilks, RJ [1 ]
机构
[1] Texas Christian Univ, Dept Engn, Ft Worth, TX 76129 USA
基金
美国国家科学基金会;
关键词
microelectromechanical systems (MEMS); microactuator; flexure; deflection and force measurements;
D O I
10.1016/S0040-6090(00)01287-6
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Several microactuator technologies have recently been investigated for positioning individual elements in large-scale microelectromechanical systems (MEMS). Electrostatic, magnetostatic, piezoelectric and thermal expansion are the most common modes of microactuator operation. This research focuses on the design and experimental characterization of two types of asymmetrical MEMS electrothermal microactuators. The motivation is to present a unified description of the behavior of the electrothermal microactuator so that it can be adapted to a variety of MEMS applications. Both MEMS polysilicon electrothermal microactuator design variants use resistive (Joule) heating to generate thermal expansion and movement. In a conventional electrothermal microactuator, the 'hot' arm is positioned parallel to a 'cold' arm, but because the 'hot' arm is narrower than the 'cold' arm, the electrical resistance of the 'hot' arm is higher. When an electric current passes through the microactuator (through the series connected electrical resistance of the 'hot' and 'cold' arms), the 'hot' arm is heated to a higher temperature than the 'cold' arm. This temperature increase causes the 'hot' arm to expand along its length, thus forcing the tip of the device to rotate about a mechanical flexure element. The new thermal actuator design eliminates the parasitic electrical resistance of the 'cold' arm by incorporating an additional 'hot' arm. The second 'hot' arm results in an improvement in electrical efficiency by providing an active return current path. Additionally, the 'cold' arm can have a narrower flexure than the flexure in a conventional single-'hot' arm device because it does not have to pass an electric current. The narrower flexure element manifests improved mechanical efficiency. Deflection and force measurements of both actuators as a function of applied electrical power have been presented in this work. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:719 / 726
页数:8
相关论文
共 24 条
[1]  
ALLEN PB, 1997, P 1997 ASEE C HOUST, P43
[2]   THERMAL BASE DRIVE FOR MICROMECHANICAL RESONATORS EMPLOYING DEEP-DIFFUSION BASES [J].
BOUWSTRA, S ;
VANROOIJEN, J ;
TILMANS, HAC ;
SELVAKUMAR, A ;
NAJAFI, K .
SENSORS AND ACTUATORS A-PHYSICAL, 1993, 37-8 :38-44
[3]   Design and performance of a double hot arm polysilicon thermal actuator [J].
Burns, DM ;
Bright, VM .
MICROMACHINED DEVICES AND COMPONENTS III, 1997, 3224 :296-306
[4]  
COCHIN I, 1997, ANAL DESIGN DYNAMIC, P309
[5]  
Comtois J H, 1996, SOL STAT SENS ACT WO, P174
[6]  
Fedder G. K., 1991, Proceedings. IEEE Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Robots (Cat. No.91CH2957-9), P63, DOI 10.1109/MEMSYS.1991.114770
[7]  
GUCKEL H, 1992, SOL STAT SENS ACT WO, P73
[8]   Hexsil tweezers for teleoperated micro-assembly [J].
Keller, CG ;
Howe, RT .
MEMS 97, PROCEEDINGS - IEEE THE TENTH ANNUAL INTERNATIONAL WORKSHOP ON MICRO ELECTRO MECHANICAL SYSTEMS: AN INVESTIGATION OF MICRO STRUCTURES, SENSORS, ACTUATORS, MACHINES AND ROBOTS, 1997, :72-77
[9]  
KOESTER D, MULTIUSER MEMS PROCE
[10]   Thermally actuated microbeam for large in-plane mechanical deflections [J].
Kolesar, ES ;
Allen, PB ;
Howard, JT ;
Wilken, JM ;
Boydston, NC .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1999, 17 (04) :2257-2263