Capacitive flexible pressure sensor: microfabrication process and experimental characterization

被引:15
作者
Dinh, T. H. N. [1 ]
Martincic, E. [1 ]
Dufour-Gergam, E. [1 ]
Joubert, P. -Y. [1 ]
机构
[1] Univ Paris 11, IEF, CNRS UMR 8622, F-91405 Orsay, France
来源
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS | 2016年 / 22卷 / 03期
关键词
POLYDIMETHYLSILOXANE;
D O I
10.1007/s00542-015-2540-5
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Kapton-based flexible pressure sensor arrays are fabricated using a new technology of film transfer. The sensors are dedicated to the non-invasive measurement of pressure/force in robotic, sport and medical applications. The sensors are of a capacitive type, and composed of two millimetric copper electrodes, separated by a polydimethylsiloxane (PDMS) deformable dielectric layer. On the flexible arrays, a very small curvature radius is possible without any damage to the sensors. The realized sensors are characterized in terms of fabrication quality. The inhomogeneity of the load free capacitances obtained in the same array is +/- 7 %. The fabrication process, which requires 14 fabrication steps, is accurate and reproducible: a 100 % transfer yield was obtained for the fabrication of 5 wafers gathering 4 sensor arrays each (215 elementary sensors). In the preliminary electro-mechanical characterization, a sensor (with a PDMS dielectric layer of 660 mu m thickness and a free load capacitance of 480 fF) undergoes a capacitance change of 17 % under a 300 kPa normal stress.
引用
收藏
页码:465 / 471
页数:7
相关论文
共 25 条
[1]   Effect of bandage thickness on interface pressure applied by compression bandages [J].
Al Khaburi, Jawad ;
Dehghani-Sanij, Abbas A. ;
Nelson, E. Andrea ;
Hutchinson, Jerry .
MEDICAL ENGINEERING & PHYSICS, 2012, 34 (03) :378-385
[2]   Hemocompatibility, biocompatibility, inflammatory and in vivo studies of primary reference materials low-density polyethylene and polydimethylsiloxane:: A review [J].
Bélanger, MC ;
Marois, Y .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (05) :467-477
[3]  
Brault S, 2011, Patent, Patent No. [WO/2011/067533, 2011067533]
[4]   MEMS packaging process by film transfer using an anti-adhesive layer [J].
Brault, Sebastien ;
Garel, O. ;
Schelcher, G. ;
Isac, N. ;
Parrain, F. ;
Bosseboeuf, A. ;
Verjus, F. ;
Desgeorges, M. ;
Dufour-Gergam, E. .
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2010, 16 (07) :1277-1284
[5]   A Wearable Sensor Network for Gait Analysis: A Six-Day Experiment of Running Through the Desert [J].
Chelius, Guillaume ;
Braillon, Christophe ;
Pasquier, Maud ;
Horvais, Nicolas ;
Gibollet, Roger Pissard ;
Espiau, Bernard ;
Coste, Christine Azevedo .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2011, 16 (05) :878-883
[6]   Fabrication of metallic patterns on polydimethylsiloxane using transfer technology: application to MRI microcoils [J].
Couty, M. ;
Nazeer, S. ;
Jelita, C. ;
Martincic, E. ;
Woytasik, M. ;
Ginefri, J-C. ;
Darrasse, L. ;
Tatoulian, M. ;
Dufour-Gergam, E. .
MICRO & NANO LETTERS, 2012, 7 (06) :519-522
[7]  
Couty M, 2012, 23 MICR MICR EUR C 9, P1
[8]  
Couty M, 2012, 2012 SYMPOSIUM ON DESIGN, TEST, INTEGRATION AND PACKAGING OF MEMS/MOEMS (DTIP), P126
[9]   Influence of cross-linker concentration on the cross-linking of PDMS and the network structures formed [J].
Esteves, A. C. C. ;
Brokken-Zijp, J. ;
Laven, J. ;
Huinink, H. P. ;
Reuvers, N. J. W. ;
Van, M. P. ;
de With, G. .
POLYMER, 2009, 50 (16) :3955-3966
[10]  
Guo Q, 2013, 2013 IEEE SENS P BAL, P507