Improved operational stability of mediated glucose enzyme electrodes for operation in human physiological solutions

被引:24
作者
Bennett, Richard [1 ,2 ]
Leech, Donal [1 ,2 ]
机构
[1] Natl Univ Ireland Galway, Sch Chem, Univ Rd, Galway, Ireland
[2] Natl Univ Ireland Galway, Ryan Inst, Univ Rd, Galway, Ireland
关键词
Enzyme electrode; Osmium redox polymer; Glucose oxidase; FADGDH; Human plasma; Uric acid; REDOX-POLYMER; FUEL-CELLS; BIOFUEL CELLS; AMPEROMETRIC DETERMINATION; CARBON NANOTUBES; OSMIUM COMPLEXES; BIOSENSOR; OXIDASE; OXIDATION; PROVIDE;
D O I
10.1016/j.bioelechem.2020.107460
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Stability of glucose-oxidising enzyme electrodes is affected by substances in physiological solutions, hampering deployment as long-term implantable biosensors or fuel cells. The performance of Nafion over-coated enzyme electrodes, consisting of multiwalled carbon nanotubes and flavin adenine dinucleotide-dependent glucose dehydrogenase (FADGDH) or glucose oxidase (GOx) crosslinked with osmium-complex based redox polymer, was compared to uncoated electrodes in presence of uric acid and artificial plasma. Nafion over-coating resulted in lower glucose oxidation current densities compared to no over-coating. The highest initial current density for Nafion over-coated electrodes in artificial plasma in 100 mM glucose was 8.0 +/- 2.0 mA cm(-2) for GOx electrodes with 0.5% w/v Nafion coating. These electrodes retained 83% of initial current after 12 h continuous operation in artificial plasma while similarly prepared FADGDH electrodes retained 58% signal. This is compared to retention of only 73% or 31% observed for GOx or FADGDH electrodes in artificial plasma with no Nafion membrane. Enzyme electrodes over-coated with Nafion maintain improved signal stability when tested continuously in the presence of uric acid, identified as being the main contributing substance to FADGDH enzyme electrode instability, showing promise for application to continuous use glucose-oxidising enzyme electrodes. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:6
相关论文
共 58 条
[31]   Kinetic control by the substrate and the cosubstrate in electrochemically monitored redox enzymatic immobilized systems.: Catalytic responses in cyclic voltammetry and steady state techniques [J].
Limoges, B ;
Moiroux, J ;
Savéant, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 521 (1-2) :8-15
[32]   Membraneless Glucose/Oxygen Enzymatic Fuel Cells Using Redox Hydrogel Films Containing Carbon Nanotubes [J].
MacAodha, Domhnall ;
Conghaile, Peter O. ;
Egan, Brenda ;
Kavanagh, Paul ;
Leech, Donal .
CHEMPHYSCHEM, 2013, 14 (10) :2302-2307
[33]   Comparison of Glucose Oxidation by Crosslinked Redox Polymer Enzyme Electrodes Containing Carbon Nanotubes and a Range of Glucose Oxidising Enzymes [J].
MacAodha, Domhnall ;
Conghaile, Peter O. ;
Egan, Brenda ;
Kavanagh, Paul ;
Sygmund, Christoph ;
Ludwig, Roland ;
Leech, Donal .
ELECTROANALYSIS, 2013, 25 (01) :94-100
[34]   Crosslinked redox polymer enzyme electrodes containing carbon nanotubes for high and stable glucose oxidation current [J].
MacAodha, Domhnall ;
Luisa Ferrer, Maria ;
Conghaile, Peter O. ;
Kavanagh, Paul ;
Leech, Donal .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2012, 14 (42) :14667-14672
[35]   Engineering glucose oxidase for bioelectrochemical applications [J].
Mano, Nicolas .
BIOELECTROCHEMISTRY, 2019, 128 :218-240
[36]   Long tethers binding redox centers to polymer backbones enhance electron transport in enzyme "wiring" hydrogels [J].
Mao, F ;
Mano, N ;
Heller, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (16) :4951-4957
[37]   State of understanding of Nafion [J].
Mauritz, KA ;
Moore, RB .
CHEMICAL REVIEWS, 2004, 104 (10) :4535-4585
[38]   Glucose biosensor based on open-source wireless microfluidic potentiostat [J].
Mercer, Conan ;
Bennett, Richard ;
Conghaile, Peter O. ;
Rusling, James F. ;
Leech, Donal .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 290 :616-624
[39]   Employing FAD-dependent glucose dehydrogenase within a glucose/oxygen enzymatic fuel cell operating in human serum [J].
Milton, Ross D. ;
Lim, Koun ;
Hickey, David P. ;
Minteer, Shelley D. .
BIOELECTROCHEMISTRY, 2015, 106 :56-63
[40]   Amperometric determination of epinephrine with an osmium complex and Nafion double-layer membrane modified electrode [J].
Ni, JA ;
Ju, HX ;
Chen, HY ;
Leech, D .