Study of UHV DC corona performance in a mini corona cage

被引:0
作者
Wang, Wei [1 ]
Li, Chengrong [1 ]
Fan, Jianbin [2 ]
Gu, Chen [2 ]
Jiang, Yitao [1 ]
Cui, Guohua [1 ]
机构
[1] N China Elect Power Univ, Minist Educ, Key Lab Power Syst Protect & Dynam Secur Monitori, Beijing Key Lab High Voltage & EMC, Beijing 102206, Peoples R China
[2] China EPRI, Beijing 100085, Peoples R China
来源
2007 ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING EXPO | 2007年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To research the effect of high altitude on corona performance of UHV DC transmission line, the corona inception voltage gradient of a copper tine at different air pressure level from 101kPa to 61kPa was measured in a mini corona cage. The results have been compared with calculated results of Peek law and the corona inception voltage gradient correction factor of air pressure was presented.
引用
收藏
页码:459 / +
页数:2
相关论文
共 50 条
  • [21] Optimization of corona ring design for ± 800 kV UHV DC transmission lines
    Key Laboratory of High Voltage Engineering and Electrical New Technology, Chongqing University, Chongqing 400044, China
    不详
    [J]. Gaodianya Jishu, 2007, 11 (33-36+93):
  • [22] High Altitude Effect on Corona Inception Voltages of DC Power Transmission Conductors Based on the Mobile Corona Cage
    Bian, Xingming
    Wang, Liming
    Liu, Yunpeng
    Yang, Yingjian
    Guan, Zhicheng
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (03) : 1971 - 1973
  • [23] Research on Corona Control in DC Voltage Withstand Test for UHV Converter Transformer
    Jin, Shuo
    Ruan, Jiangjun
    Du, Zhiye
    Gong, Ruohan
    Zhu, Lin
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [24] Measurement of Space Charge in Negative Corona on a Small Corona Cage
    Liao, RuiJin
    Liu, KangLin
    Liu, HongBo
    Wu, FeiFei
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (04) : 2344 - 2352
  • [25] STUDIES ON CORONA PERFORMANCE OF INSULATOR ASSEMBLIES FOR UHV TRANSMISSION-LINES
    FUJIMURA, T
    NAITO, K
    HASEGAWA, Y
    MATSUOKA, R
    NAKASHIMA, Y
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (03): : 860 - 870
  • [26] Corona Performance of Double Pendulum Damper for UHV AC Transmission Lines
    Quan S.
    Li F.
    Zhang R.
    Deng J.
    Zhang H.
    Yuan G.
    [J]. Dianwang Jishu/Power System Technology, 2023, 47 (10): : 4342 - 4348
  • [27] The effect of air pressure on the surface electric field intensity characteristics under negative DC corona discharge in a corona cage
    Liu, Hongbo
    Liao, Ruijin
    Zhao, Xuetong
    Lin, Yuandi
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 113 : 244 - 250
  • [28] The effect of temperature and humidity on corona inception voltage gradient of UHV DC transmission line
    Wang, Wei
    Li, Chengrong
    Lu, Bing
    Li, Xiaolin
    Jiang, Yitao
    An, Bing
    Wang, Yixu
    [J]. PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 816 - +
  • [29] AC Conductors' Corona-Loss Calculation and Analysis in Corona Cage
    Lu, Fang-Cheng
    You, Shao-Hua
    Liu, Yun-Peng
    Wan, Qi-Fa
    Zhao, Zhi-Bin
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (02) : 877 - 885
  • [30] AC transmission line corona noise issues in a small corona cage
    Urban, RG
    Reader, HC
    Holtzhausen, JP
    [J]. 2002 IEEE AFRICON, VOLS 1 AND 2: ELECTROTECHNOLOGICAL SERVICES FOR AFRICA, 2002, : 639 - 644