Performance of surge arrester to multiple lightning strokes on nearby distribution transformer

被引:0
|
作者
Omidiora, M. A. [1 ]
Lehtonen, M. [1 ]
机构
[1] Aalto Univ, Power Syst & High Voltage Lab, FIN-02150 Espoo, Finland
关键词
lightning strokes; surge arrester; ATPDraw; transient overvoltages;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Overhead distribution lines are prone to lightning overvoltages due to their configurations and characteristics. Metal Oxide Varistor (MOVs) arresters for many years have proven to be more advantageous than others arresters in lightning surge protection; therefore it is worthwhile to continually assess the behavior and performance of these arresters to different kind of overvoltages caused by lightning strokes for power system applications. This paper presents the performance of MOV arresters to multiple lightning strokes nearby a substation transformer. All simulations were performed with Alternative Transients Program/Electromagnetic Transients Program (ATP/EMTP Program).
引用
收藏
页码:59 / +
页数:3
相关论文
共 50 条
  • [41] Protection of radar systems against nearby or direct lightning strokes
    Annunziata, A.
    Dominicis, A.
    Antonini, G.
    Orlandi, A.
    Fiamingo, F.
    Mazzetti, C.
    2008 IEEE RADAR CONFERENCE, VOLS. 1-4, 2008, : 1376 - +
  • [42] Effect of Stray Capacitance on Surge Arrester Performance
    Valsalal, P.
    Usa, S.
    Udayakumar, K.
    WCECS 2009: WORLD CONGRESS ON ENGINEERING AND COMPUTER SCIENCE, VOLS I AND II, 2009, : 541 - 544
  • [43] Performance of Surge Arrestors Under Single and Multiple Lightning Impulses
    Koch, Maik
    2017 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XIV SIPDA), 2017, : 176 - 182
  • [44] LIGHTNING PERFORMANCE AND OVERVOLTAGE SURGE STUDIES ON A RURAL DISTRIBUTION LINE
    ERIKSSON, AJ
    MEAL, DV
    IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1982, 129 (02) : 59 - 69
  • [45] Influence of Lightning Channel Impedance and Nonuniform Tower Footing Resistance Distribution on Line Surge Arrester Energy Duty
    Grebovic, Selma
    Oprasic, Nermin
    2018 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE EUROPE (ISGT-EUROPE), 2018,
  • [46] Study of Lightning Surge Overvoltages at Substations Due to Direct Lightning Strokes to Phase Conductors
    Takami, Jun
    Okabe, Shigemitsu
    Zaima, Eiichi
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (01) : 425 - 433
  • [47] Estimation of the Influence of Direct strokes on the Lightning Performance of Overhead Distribution Lines
    Tossani, F.
    Napolitano, F.
    Borghetti, A.
    Nucci, C. A.
    Lopes, G. P.
    Martinez, M. L. B.
    dos Santos, G. J. G.
    2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [48] Evaluation of line surge arrester failure rate using multipulse lightning stresses
    Zanetta, LC
    2002 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS, 2002, : 368 - 368
  • [49] DEVELOPMENT OF A NON-FRAGMENTING DISTRIBUTION SURGE ARRESTER
    KOCH, RE
    SONGSTER, HJ
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (11): : 3342 - 3353
  • [50] Surge Current Flowing in the Small Boat due to the Nearby Lightning
    Akehashi K.
    Ikeda Y.